ABAP Select data from SAP table OIC_ROICQ7 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIC_ROICQ7 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIC_ROICQ7. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIC_ROICQ7 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIC_ROICQ7 TYPE STANDARD TABLE OF OIC_ROICQ7, WA_OIC_ROICQ7 TYPE OIC_ROICQ7, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIC_ROICQ7> TYPE OIC_ROICQ7. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIC_ROICQ7. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIC_ROICQ7 INTO TABLE IT_OIC_ROICQ7. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIC_ROICQ7 * INTO TABLE @DATA(IT_OIC_ROICQ72). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIC_ROICQ7 INDEX 1 INTO DATA(WA_OIC_ROICQ72). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIC_ROICQ7 ASSIGNING <OIC_ROICQ7>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIC_ROICQ7>-KSCHL = 1.
<OIC_ROICQ7>-KNUMH = 1.
<OIC_ROICQ7>-MANDT = 1.
<OIC_ROICQ7>-KNUMV = 1.
<OIC_ROICQ7>-KPOSN = 1.
ENDLOOP. LOOP AT IT_OIC_ROICQ7 INTO WA_OIC_ROICQ7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIC_ROICQ7-STUNR, sy-vline,
WA_OIC_ROICQ7-ZAEHK, sy-vline,
WA_OIC_ROICQ7-FORAVB, sy-vline,
WA_OIC_ROICQ7-FORDESC, sy-vline,
WA_OIC_ROICQ7-FORMVAL, sy-vline,
WA_OIC_ROICQ7-FORMCURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIC_ROICQ7 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIC_ROICQ7 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIC_ROICQ7 INTO WA_OIC_ROICQ7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field FORMUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIC_ROICQ7-FORMUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIC_ROICQ7-FORMUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIC_ROICQ7_STR,
KSCHL TYPE STRING,
KNUMH TYPE STRING,
MANDT TYPE STRING,
KNUMV TYPE STRING,
KPOSN TYPE STRING,
STUNR TYPE STRING,
ZAEHK TYPE STRING,
FORAVB TYPE STRING,
FORDESC TYPE STRING,
FORMVAL TYPE STRING,
FORMCURR TYPE STRING,
FORSTATUS TYPE STRING,
RATECURR TYPE STRING,
FORMUOM TYPE STRING,
FORMPER TYPE STRING,
UOMCNVRL TYPE STRING,
FORMUMZA TYPE STRING,
FORMUMNE TYPE STRING,
RATEBASED TYPE STRING,
_DATAAGING TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIC_ROICQ7_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIC_ROICQ7_STR-KSCHL sy-vline
WA_OIC_ROICQ7_STR-KNUMH sy-vline
WA_OIC_ROICQ7_STR-MANDT sy-vline
WA_OIC_ROICQ7_STR-KNUMV sy-vline
WA_OIC_ROICQ7_STR-KPOSN sy-vline
WA_OIC_ROICQ7_STR-STUNR sy-vline
WA_OIC_ROICQ7_STR-ZAEHK sy-vline
WA_OIC_ROICQ7_STR-FORAVB sy-vline
WA_OIC_ROICQ7_STR-FORDESC sy-vline
WA_OIC_ROICQ7_STR-FORMVAL sy-vline
WA_OIC_ROICQ7_STR-FORMCURR sy-vline
WA_OIC_ROICQ7_STR-FORSTATUS sy-vline
WA_OIC_ROICQ7_STR-RATECURR sy-vline
WA_OIC_ROICQ7_STR-FORMUOM sy-vline
WA_OIC_ROICQ7_STR-FORMPER sy-vline
WA_OIC_ROICQ7_STR-UOMCNVRL sy-vline
WA_OIC_ROICQ7_STR-FORMUMZA sy-vline
WA_OIC_ROICQ7_STR-FORMUMNE sy-vline
WA_OIC_ROICQ7_STR-RATEBASED sy-vline
WA_OIC_ROICQ7_STR-_DATAAGING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.