ABAP Select data from SAP table OIG_WEB_DEL_CONF_PROTOTYPE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIG_WEB_DEL_CONF_PROTOTYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIG_WEB_DEL_CONF_PROTOTYPE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIG_WEB_DEL_CONF_PROTOTYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIG_WEB_DEL_CONF_PROTOTYPE TYPE STANDARD TABLE OF OIG_WEB_DEL_CONF_PROTOTYPE, WA_OIG_WEB_DEL_CONF_PROTOTYPE TYPE OIG_WEB_DEL_CONF_PROTOTYPE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIG_WEB_DEL_CONF_PROTOTYPE> TYPE OIG_WEB_DEL_CONF_PROTOTYPE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIG_WEB_DEL_CONF_PROTOTYPE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIG_WEB_DEL_CONF_PROTOTYPE INTO TABLE IT_OIG_WEB_DEL_CONF_PROTOTYPE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIG_WEB_DEL_CONF_PROTOTYPE * INTO TABLE @DATA(IT_OIG_WEB_DEL_CONF_PROTOTYPE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIG_WEB_DEL_CONF_PROTOTYPE INDEX 1 INTO DATA(WA_OIG_WEB_DEL_CONF_PROTOTYPE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIG_WEB_DEL_CONF_PROTOTYPE ASSIGNING <OIG_WEB_DEL_CONF_PROTOTYPE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIG_WEB_DEL_CONF_PROTOTYPE>-DOC_NUMBER = 1.
<OIG_WEB_DEL_CONF_PROTOTYPE>-DOC_TYP = 1.
<OIG_WEB_DEL_CONF_PROTOTYPE>-POSNR = 1.
<OIG_WEB_DEL_CONF_PROTOTYPE>-MATNR = 1.
<OIG_WEB_DEL_CONF_PROTOTYPE>-PARTNERID = 1.
ENDLOOP. LOOP AT IT_OIG_WEB_DEL_CONF_PROTOTYPE INTO WA_OIG_WEB_DEL_CONF_PROTOTYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIG_WEB_DEL_CONF_PROTOTYPE-NAME1, sy-vline,
WA_OIG_WEB_DEL_CONF_PROTOTYPE-TRQTY_C, sy-vline,
WA_OIG_WEB_DEL_CONF_PROTOTYPE-TRUOM, sy-vline,
WA_OIG_WEB_DEL_CONF_PROTOTYPE-SCLD_QTY_C, sy-vline,
WA_OIG_WEB_DEL_CONF_PROTOTYPE-DLTEMP, sy-vline,
WA_OIG_WEB_DEL_CONF_PROTOTYPE-DLTUOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIG_WEB_DEL_CONF_PROTOTYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIG_WEB_DEL_CONF_PROTOTYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIG_WEB_DEL_CONF_PROTOTYPE INTO WA_OIG_WEB_DEL_CONF_PROTOTYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DOC_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-DOC_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-DOC_NUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN5, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field TRUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-TRUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-TRUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field DLTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-DLTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-DLTUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SHNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-SHNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-SHNUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VEHICLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-VEHICLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-VEHICLE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIG_WEB_DEL_CONF_PROTOTYPE-MATNR_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIG_WEB_DEL_CONF_PROTOTYPE-MATNR_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIG_WEB_DEL_CONF_PROTOTYPE_STR,
DOC_NUMBER TYPE STRING,
DOC_TYP TYPE STRING,
POSNR TYPE STRING,
MATNR TYPE STRING,
PARTNERID TYPE STRING,
NAME1 TYPE STRING,
TRQTY_C TYPE STRING,
TRUOM TYPE STRING,
SCLD_QTY_C TYPE STRING,
DLTEMP TYPE STRING,
DLTUOM TYPE STRING,
DLDATE TYPE STRING,
DLTIME TYPE STRING,
SHNUMBER TYPE STRING,
VEHICLE TYPE STRING,
SHITEM TYPE STRING,
MAT_ITM TYPE STRING,
VEH_NR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
UPDATEFLAG TYPE STRING,
QTY_ITM TYPE STRING,
MATNR_LONG TYPE STRING,
DOC_TYP_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DOC_NUMBER sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DOC_TYP sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-POSNR sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-MATNR sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-PARTNERID sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-NAME1 sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-TRQTY_C sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-TRUOM sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-SCLD_QTY_C sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DLTEMP sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DLTUOM sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DLDATE sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DLTIME sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-SHNUMBER sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-VEHICLE sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-SHITEM sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-MAT_ITM sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-VEH_NR sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-WERKS sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-LGORT sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-UPDATEFLAG sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-QTY_ITM sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-MATNR_LONG sy-vline
WA_OIG_WEB_DEL_CONF_PROTOTYPE_STR-DOC_TYP_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.