ABAP Select data from SAP table OIJ05_BULKFRCT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIJ05_BULKFRCT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIJ05_BULKFRCT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIJ05_BULKFRCT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIJ05_BULKFRCT TYPE STANDARD TABLE OF OIJ05_BULKFRCT,
      WA_OIJ05_BULKFRCT TYPE OIJ05_BULKFRCT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIJ05_BULKFRCT> TYPE OIJ05_BULKFRCT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIJ05_BULKFRCT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIJ05_BULKFRCT
  INTO TABLE IT_OIJ05_BULKFRCT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIJ05_BULKFRCT
*  INTO TABLE @DATA(IT_OIJ05_BULKFRCT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIJ05_BULKFRCT INDEX 1 INTO DATA(WA_OIJ05_BULKFRCT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIJ05_BULKFRCT ASSIGNING <OIJ05_BULKFRCT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIJ05_BULKFRCT>-MANDT = 1.
<OIJ05_BULKFRCT>-LOCID = 1.
<OIJ05_BULKFRCT>-MATNR = 1.
<OIJ05_BULKFRCT>-CHARG = 1.
<OIJ05_BULKFRCT>-DATUM = 1.
ENDLOOP.

LOOP AT IT_OIJ05_BULKFRCT INTO WA_OIJ05_BULKFRCT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIJ05_BULKFRCT-VKTRA, sy-vline,
WA_OIJ05_BULKFRCT-BFCTYPE, sy-vline,
WA_OIJ05_BULKFRCT-BTHPUT, sy-vline,
WA_OIJ05_BULKFRCT-THPUTUOM, sy-vline,
WA_OIJ05_BULKFRCT-ERDAT, sy-vline,
WA_OIJ05_BULKFRCT-ERZEIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIJ05_BULKFRCT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIJ05_BULKFRCT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIJ05_BULKFRCT INTO WA_OIJ05_BULKFRCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIJ05_BULKFRCT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_BULKFRCT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field THPUTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJ05_BULKFRCT-THPUTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_BULKFRCT-THPUTUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIJ05_BULKFRCT_STR,
MANDT TYPE STRING,
LOCID TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
DATUM TYPE STRING,
VKTRA TYPE STRING,
BFCTYPE TYPE STRING,
BTHPUT TYPE STRING,
THPUTUOM TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
BLOIND TYPE STRING,
DELIND TYPE STRING,
TKTSELECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIJ05_BULKFRCT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIJ05_BULKFRCT_STR-MANDT sy-vline
WA_OIJ05_BULKFRCT_STR-LOCID sy-vline
WA_OIJ05_BULKFRCT_STR-MATNR sy-vline
WA_OIJ05_BULKFRCT_STR-CHARG sy-vline
WA_OIJ05_BULKFRCT_STR-DATUM sy-vline
WA_OIJ05_BULKFRCT_STR-VKTRA sy-vline
WA_OIJ05_BULKFRCT_STR-BFCTYPE sy-vline
WA_OIJ05_BULKFRCT_STR-BTHPUT sy-vline
WA_OIJ05_BULKFRCT_STR-THPUTUOM sy-vline
WA_OIJ05_BULKFRCT_STR-ERDAT sy-vline
WA_OIJ05_BULKFRCT_STR-ERZEIT sy-vline
WA_OIJ05_BULKFRCT_STR-ERNAM sy-vline
WA_OIJ05_BULKFRCT_STR-AEDAT sy-vline
WA_OIJ05_BULKFRCT_STR-AEZEIT sy-vline
WA_OIJ05_BULKFRCT_STR-AENAM sy-vline
WA_OIJ05_BULKFRCT_STR-BLOIND sy-vline
WA_OIJ05_BULKFRCT_STR-DELIND sy-vline
WA_OIJ05_BULKFRCT_STR-TKTSELECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.