ABAP Select data from SAP table OIJ05_S_SPW_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIJ05_S_SPW_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIJ05_S_SPW_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIJ05_S_SPW_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIJ05_S_SPW_DATA TYPE STANDARD TABLE OF OIJ05_S_SPW_DATA,
      WA_OIJ05_S_SPW_DATA TYPE OIJ05_S_SPW_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIJ05_S_SPW_DATA> TYPE OIJ05_S_SPW_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIJ05_S_SPW_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIJ05_S_SPW_DATA
  INTO TABLE IT_OIJ05_S_SPW_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIJ05_S_SPW_DATA
*  INTO TABLE @DATA(IT_OIJ05_S_SPW_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIJ05_S_SPW_DATA INDEX 1 INTO DATA(WA_OIJ05_S_SPW_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIJ05_S_SPW_DATA ASSIGNING <OIJ05_S_SPW_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIJ05_S_SPW_DATA>-LOCID = 1.
<OIJ05_S_SPW_DATA>-TSYST = 1.
<OIJ05_S_SPW_DATA>-MATNR = 1.
<OIJ05_S_SPW_DATA>-DATUM = 1.
<OIJ05_S_SPW_DATA>-S_PHY_INV = 1.
ENDLOOP.

LOOP AT IT_OIJ05_S_SPW_DATA INTO WA_OIJ05_S_SPW_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIJ05_S_SPW_DATA-S_BOOK_INV, sy-vline,
WA_OIJ05_S_SPW_DATA-E_PHY_INV, sy-vline,
WA_OIJ05_S_SPW_DATA-E_BOOK_INV, sy-vline,
WA_OIJ05_S_SPW_DATA-UOM, sy-vline,
WA_OIJ05_S_SPW_DATA-DOCUMENTQTY, sy-vline,
WA_OIJ05_S_SPW_DATA-DOCNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIJ05_S_SPW_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIJ05_S_SPW_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIJ05_S_SPW_DATA INTO WA_OIJ05_S_SPW_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIJ05_S_SPW_DATA-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_S_SPW_DATA-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJ05_S_SPW_DATA-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_S_SPW_DATA-UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ05_S_SPW_DATA-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_S_SPW_DATA-DOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NOMTK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ05_S_SPW_DATA-NOMTK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_S_SPW_DATA-NOMTK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SIM_SCHED_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ05_S_SPW_DATA-SIM_SCHED_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ05_S_SPW_DATA-SIM_SCHED_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIJ05_S_SPW_DATA_STR,
LOCID TYPE STRING,
TSYST TYPE STRING,
MATNR TYPE STRING,
DATUM TYPE STRING,
S_PHY_INV TYPE STRING,
S_BOOK_INV TYPE STRING,
E_PHY_INV TYPE STRING,
E_BOOK_INV TYPE STRING,
UOM TYPE STRING,
DOCUMENTQTY TYPE STRING,
DOCNR TYPE STRING,
DOCITM TYPE STRING,
SCHEDULEDQTY TYPE STRING,
ACTQTY TYPE STRING,
IRACT TYPE STRING,
IFCAST TYPE STRING,
ICORR TYPE STRING,
FCTYPE TYPE STRING,
RACK_SIM TYPE STRING,
RACK_UPDKZ TYPE STRING,
FCAST_SIM TYPE STRING,
FCAST_UPDKZ TYPE STRING,
PROD TYPE STRING,
IPROD TYPE STRING,
NOMNR TYPE STRING,
NOMIT TYPE STRING,
NOMTK TYPE STRING,
SIM_SCHED_ID TYPE STRING,
SIM_SCHED_LN TYPE STRING,
UPDKZ TYPE STRING,
SCHED_COMM TYPE STRING,
NOM_SIM TYPE STRING,
PHY_E_SIM TYPE STRING,
PHY_S_SIM TYPE STRING,
FULLY_ACTUALIZED TYPE STRING,
TKT_QTY TYPE STRING,
VALTYPE TYPE STRING,
BASELINE TYPE STRING,
IPW_UNACTUALQTY TYPE STRING,
BTHPUT TYPE STRING,
FCAST_CONS TYPE STRING,
PHY_INV_MANUAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIJ05_S_SPW_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIJ05_S_SPW_DATA_STR-LOCID sy-vline
WA_OIJ05_S_SPW_DATA_STR-TSYST sy-vline
WA_OIJ05_S_SPW_DATA_STR-MATNR sy-vline
WA_OIJ05_S_SPW_DATA_STR-DATUM sy-vline
WA_OIJ05_S_SPW_DATA_STR-S_PHY_INV sy-vline
WA_OIJ05_S_SPW_DATA_STR-S_BOOK_INV sy-vline
WA_OIJ05_S_SPW_DATA_STR-E_PHY_INV sy-vline
WA_OIJ05_S_SPW_DATA_STR-E_BOOK_INV sy-vline
WA_OIJ05_S_SPW_DATA_STR-UOM sy-vline
WA_OIJ05_S_SPW_DATA_STR-DOCUMENTQTY sy-vline
WA_OIJ05_S_SPW_DATA_STR-DOCNR sy-vline
WA_OIJ05_S_SPW_DATA_STR-DOCITM sy-vline
WA_OIJ05_S_SPW_DATA_STR-SCHEDULEDQTY sy-vline
WA_OIJ05_S_SPW_DATA_STR-ACTQTY sy-vline
WA_OIJ05_S_SPW_DATA_STR-IRACT sy-vline
WA_OIJ05_S_SPW_DATA_STR-IFCAST sy-vline
WA_OIJ05_S_SPW_DATA_STR-ICORR sy-vline
WA_OIJ05_S_SPW_DATA_STR-FCTYPE sy-vline
WA_OIJ05_S_SPW_DATA_STR-RACK_SIM sy-vline
WA_OIJ05_S_SPW_DATA_STR-RACK_UPDKZ sy-vline
WA_OIJ05_S_SPW_DATA_STR-FCAST_SIM sy-vline
WA_OIJ05_S_SPW_DATA_STR-FCAST_UPDKZ sy-vline
WA_OIJ05_S_SPW_DATA_STR-PROD sy-vline
WA_OIJ05_S_SPW_DATA_STR-IPROD sy-vline
WA_OIJ05_S_SPW_DATA_STR-NOMNR sy-vline
WA_OIJ05_S_SPW_DATA_STR-NOMIT sy-vline
WA_OIJ05_S_SPW_DATA_STR-NOMTK sy-vline
WA_OIJ05_S_SPW_DATA_STR-SIM_SCHED_ID sy-vline
WA_OIJ05_S_SPW_DATA_STR-SIM_SCHED_LN sy-vline
WA_OIJ05_S_SPW_DATA_STR-UPDKZ sy-vline
WA_OIJ05_S_SPW_DATA_STR-SCHED_COMM sy-vline
WA_OIJ05_S_SPW_DATA_STR-NOM_SIM sy-vline
WA_OIJ05_S_SPW_DATA_STR-PHY_E_SIM sy-vline
WA_OIJ05_S_SPW_DATA_STR-PHY_S_SIM sy-vline
WA_OIJ05_S_SPW_DATA_STR-FULLY_ACTUALIZED sy-vline
WA_OIJ05_S_SPW_DATA_STR-TKT_QTY sy-vline
WA_OIJ05_S_SPW_DATA_STR-VALTYPE sy-vline
WA_OIJ05_S_SPW_DATA_STR-BASELINE sy-vline
WA_OIJ05_S_SPW_DATA_STR-IPW_UNACTUALQTY sy-vline
WA_OIJ05_S_SPW_DATA_STR-BTHPUT sy-vline
WA_OIJ05_S_SPW_DATA_STR-FCAST_CONS sy-vline
WA_OIJ05_S_SPW_DATA_STR-PHY_INV_MANUAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.