ABAP Select data from SAP table OIJ_OIL_ADD_IO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIJ_OIL_ADD_IO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIJ_OIL_ADD_IO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIJ_OIL_ADD_IO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIJ_OIL_ADD_IO TYPE STANDARD TABLE OF OIJ_OIL_ADD_IO, WA_OIJ_OIL_ADD_IO TYPE OIJ_OIL_ADD_IO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIJ_OIL_ADD_IO> TYPE OIJ_OIL_ADD_IO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIJ_OIL_ADD_IO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIJ_OIL_ADD_IO INTO TABLE IT_OIJ_OIL_ADD_IO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIJ_OIL_ADD_IO * INTO TABLE @DATA(IT_OIJ_OIL_ADD_IO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIJ_OIL_ADD_IO INDEX 1 INTO DATA(WA_OIJ_OIL_ADD_IO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIJ_OIL_ADD_IO ASSIGNING <OIJ_OIL_ADD_IO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIJ_OIL_ADD_IO>-OITAXFROM = 1.
<OIJ_OIL_ADD_IO>-OIHANTYP = 1.
<OIJ_OIL_ADD_IO>-OITAXGRP = 1.
<OIJ_OIL_ADD_IO>-OITAXTO = 1.
<OIJ_OIL_ADD_IO>-OIOILCON = 1.
ENDLOOP. LOOP AT IT_OIJ_OIL_ADD_IO INTO WA_OIJ_OIL_ADD_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIJ_OIL_ADD_IO-OIEDBAL, sy-vline,
WA_OIJ_OIL_ADD_IO-OIPRICIE, sy-vline,
WA_OIJ_OIL_ADD_IO-OIINEX, sy-vline,
WA_OIJ_OIL_ADD_IO-OIEDBALM, sy-vline,
WA_OIJ_OIL_ADD_IO-LOG_PROC, sy-vline,
WA_OIJ_OIL_ADD_IO-TAX_PROC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIJ_OIL_ADD_IO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIJ_OIL_ADD_IO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIJ_OIL_ADD_IO INTO WA_OIJ_OIL_ADD_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field OIH_LICIN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-OIH_LICIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-OIH_LICIN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIH_LCFOL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-OIH_LCFOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-OIH_LCFOL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIH_LICIN_GI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-OIH_LICIN_GI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-OIH_LICIN_GI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIH_LCFOL_GI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-OIH_LCFOL_GI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-OIH_LCFOL_GI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIC_LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-OIC_LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-OIC_LIFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LICIN_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-LICIN_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-LICIN_NUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SHIP_FROM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-SHIP_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-SHIP_FROM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DUTY_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ_OIL_ADD_IO-DUTY_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ_OIL_ADD_IO-DUTY_TO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIJ_OIL_ADD_IO_STR,
OITAXFROM TYPE STRING,
OIHANTYP TYPE STRING,
OITAXGRP TYPE STRING,
OITAXTO TYPE STRING,
OIOILCON TYPE STRING,
OIEDBAL TYPE STRING,
OIPRICIE TYPE STRING,
OIINEX TYPE STRING,
OIEDBALM TYPE STRING,
LOG_PROC TYPE STRING,
TAX_PROC TYPE STRING,
OICERTF1 TYPE STRING,
OIDATFM1 TYPE STRING,
OIDATTO1 TYPE STRING,
OIH_LICTP TYPE STRING,
OIH_LICIN TYPE STRING,
OIH_LCFOL TYPE STRING,
OIH_FOLQTY TYPE STRING,
OICERTF1_GI TYPE STRING,
OIDATFM1_GI TYPE STRING,
OIDATTO1_GI TYPE STRING,
OIH_LICTP_GI TYPE STRING,
OIH_LICIN_GI TYPE STRING,
OIH_LCFOL_GI TYPE STRING,
OIH_FOLQTY_GI TYPE STRING,
OIPIPEVAL TYPE STRING,
OIC_LIFNR TYPE STRING,
OIC_DCITYC TYPE STRING,
OIC_DCOUNC TYPE STRING,
OIC_DREGIO TYPE STRING,
OIC_DLAND1 TYPE STRING,
OIC_OCITYC TYPE STRING,
OIC_OCOUNC TYPE STRING,
OIC_OREGIO TYPE STRING,
OIC_OLAND1 TYPE STRING,
OIC_PORGIN TYPE STRING,
OIC_PDESTN TYPE STRING,
OIC_PTRIP TYPE STRING,
OIC_PBATCH TYPE STRING,
OIC_MOT TYPE STRING,
OIC_AORGIN TYPE STRING,
OIC_ADESTN TYPE STRING,
OIC_TRUCKN TYPE STRING,
OIA_BASELO TYPE STRING,
OIEDOK TYPE STRING,
OIEDOK_GI TYPE STRING,
OIEDBAL_GI TYPE STRING,
OIEDBALM_GI TYPE STRING,
OIHANTYP_GI TYPE STRING,
OIINEX_GI TYPE STRING,
OITAXGRP_GI TYPE STRING,
OITAXFROM_GI TYPE STRING,
OITAXTO_GI TYPE STRING,
OITAXGRP_TEXT TYPE STRING,
OIHANTYP_TEXT TYPE STRING,
OIINEX_TEXT TYPE STRING,
OITAXFROM_TEXT TYPE STRING,
OITAXTO_TEXT TYPE STRING,
OIHANTYPGI_TEXT TYPE STRING,
OITAXGRPGI_TEXT TYPE STRING,
OIINEX_GI_TEXT TYPE STRING,
LOG_PROC_TEXT TYPE STRING,
TAX_PROC_TEXT TYPE STRING,
BWTAR_INTRANSIT TYPE STRING,
HT_GL TYPE STRING,
HT_LOAD TYPE STRING,
HT_DIS TYPE STRING,
LICIN_NUM TYPE STRING,
LICEXT_NUM TYPE STRING,
OIH_DISTLIC TYPE STRING,
SHIP_FROM TYPE STRING,
DUTY_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIJ_OIL_ADD_IO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXFROM sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIHANTYP sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXGRP sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXTO sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIOILCON sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIEDBAL sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIPRICIE sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIINEX sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIEDBALM sy-vline
WA_OIJ_OIL_ADD_IO_STR-LOG_PROC sy-vline
WA_OIJ_OIL_ADD_IO_STR-TAX_PROC sy-vline
WA_OIJ_OIL_ADD_IO_STR-OICERTF1 sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIDATFM1 sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIDATTO1 sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_LICTP sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_LICIN sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_LCFOL sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_FOLQTY sy-vline
WA_OIJ_OIL_ADD_IO_STR-OICERTF1_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIDATFM1_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIDATTO1_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_LICTP_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_LICIN_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_LCFOL_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_FOLQTY_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIPIPEVAL sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_LIFNR sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_DCITYC sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_DCOUNC sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_DREGIO sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_DLAND1 sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_OCITYC sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_OCOUNC sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_OREGIO sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_OLAND1 sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_PORGIN sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_PDESTN sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_PTRIP sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_PBATCH sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_MOT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_AORGIN sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_ADESTN sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIC_TRUCKN sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIA_BASELO sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIEDOK sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIEDOK_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIEDBAL_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIEDBALM_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIHANTYP_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIINEX_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXGRP_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXFROM_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXTO_GI sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXGRP_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIHANTYP_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIINEX_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXFROM_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXTO_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIHANTYPGI_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OITAXGRPGI_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIINEX_GI_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-LOG_PROC_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-TAX_PROC_TEXT sy-vline
WA_OIJ_OIL_ADD_IO_STR-BWTAR_INTRANSIT sy-vline
WA_OIJ_OIL_ADD_IO_STR-HT_GL sy-vline
WA_OIJ_OIL_ADD_IO_STR-HT_LOAD sy-vline
WA_OIJ_OIL_ADD_IO_STR-HT_DIS sy-vline
WA_OIJ_OIL_ADD_IO_STR-LICIN_NUM sy-vline
WA_OIJ_OIL_ADD_IO_STR-LICEXT_NUM sy-vline
WA_OIJ_OIL_ADD_IO_STR-OIH_DISTLIC sy-vline
WA_OIJ_OIL_ADD_IO_STR-SHIP_FROM sy-vline
WA_OIJ_OIL_ADD_IO_STR-DUTY_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.