ABAP Select data from SAP table OIJLOCMAT_N into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIJLOCMAT_N table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIJLOCMAT_N. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIJLOCMAT_N table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIJLOCMAT_N TYPE STANDARD TABLE OF OIJLOCMAT_N, WA_OIJLOCMAT_N TYPE OIJLOCMAT_N, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIJLOCMAT_N> TYPE OIJLOCMAT_N. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIJLOCMAT_N. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIJLOCMAT_N INTO TABLE IT_OIJLOCMAT_N. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIJLOCMAT_N * INTO TABLE @DATA(IT_OIJLOCMAT_N2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIJLOCMAT_N INDEX 1 INTO DATA(WA_OIJLOCMAT_N2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIJLOCMAT_N ASSIGNING <OIJLOCMAT_N>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIJLOCMAT_N>-MANDT = 1.
<OIJLOCMAT_N>-LOCID = 1.
<OIJLOCMAT_N>-PMATNR = 1.
<OIJLOCMAT_N>-LOCNAME = 1.
<OIJLOCMAT_N>-PMATNAME = 1.
ENDLOOP. LOOP AT IT_OIJLOCMAT_N INTO WA_OIJLOCMAT_N. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIJLOCMAT_N-PWERK, sy-vline,
WA_OIJLOCMAT_N-CHARG, sy-vline,
WA_OIJLOCMAT_N-RDUOM, sy-vline,
WA_OIJLOCMAT_N-RDCONV, sy-vline,
WA_OIJLOCMAT_N-PERIOD, sy-vline,
WA_OIJLOCMAT_N-PAST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIJLOCMAT_N you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIJLOCMAT_N TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIJLOCMAT_N INTO WA_OIJLOCMAT_N. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN5, internal->external for field PMATNR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-PMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-PMATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field RDUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-RDUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-RDUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field DATUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-DATUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-DATUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field PLUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-PLUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-PLUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field CYCUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-CYCUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-CYCUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field INVUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-INVUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-INVUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-SPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-SPART.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field OFFUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-OFFUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-OFFUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field BOMALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-BOMALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-BOMALT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN5, internal->external for field BOMMAT CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-BOMMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-BOMMAT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LBUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-LBUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-LBUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PMATNR_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-PMATNR_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-PMATNR_LONG.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field BOMMAT_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIJLOCMAT_N-BOMMAT_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJLOCMAT_N-BOMMAT_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIJLOCMAT_N_STR,
MANDT TYPE STRING,
LOCID TYPE STRING,
PMATNR TYPE STRING,
LOCNAME TYPE STRING,
PMATNAME TYPE STRING,
PWERK TYPE STRING,
CHARG TYPE STRING,
RDUOM TYPE STRING,
RDCONV TYPE STRING,
PERIOD TYPE STRING,
PAST TYPE STRING,
TOLPCT TYPE STRING,
TOLABS TYPE STRING,
PASTDATA TYPE STRING,
PHY_INV_FLG TYPE STRING,
PHY_INV TYPE STRING,
PHY_DATE TYPE STRING,
FCPAST TYPE STRING,
FCOFFSET TYPE STRING,
FCTYPE TYPE STRING,
PHYTMS TYPE STRING,
SRCTYPE TYPE STRING,
FCHORIZ TYPE STRING,
RVP TYPE STRING,
PLTYP TYPE STRING,
CALFLG TYPE STRING,
PLCAL TYPE STRING,
COVER TYPE STRING,
PLHOZ TYPE STRING,
DATUOM TYPE STRING,
PTSYST TYPE STRING,
PLUOM TYPE STRING,
CYCLE TYPE STRING,
CYCUOM TYPE STRING,
MAXLOT TYPE STRING,
MINLOT TYPE STRING,
INCLOT TYPE STRING,
INVUOM TYPE STRING,
MAXINV TYPE STRING,
TARGET TYPE STRING,
REORDER TYPE STRING,
SAFETY TYPE STRING,
UNPUMP TYPE STRING,
MININV TYPE STRING,
STSYST TYPE STRING,
SLOCID TYPE STRING,
SPART TYPE STRING,
SPOBJ TYPE STRING,
OFFPER TYPE STRING,
OFFUOM TYPE STRING,
RADIONOSRC TYPE STRING,
RADIOTSSRC TYPE STRING,
RADIOLOCSC TYPE STRING,
PLANAMPEL TYPE STRING,
PLANFLAG TYPE STRING,
SCFLAG TYPE STRING,
SERVICE TYPE STRING,
COVPROF TYPE STRING,
CALPROF TYPE STRING,
FACTORY TYPE STRING,
SFTTYPE TYPE STRING,
HISTHOZ TYPE STRING,
TSERVICE TYPE STRING,
TCOVPROF TYPE STRING,
TCALPROF TYPE STRING,
TFACTORY TYPE STRING,
TGTTYPE TYPE STRING,
THISTHOZ TYPE STRING,
FCCAL TYPE STRING,
FCPRF TYPE STRING,
TANKUPD TYPE STRING,
SFTLVL TYPE STRING,
HRLVL TYPE STRING,
SFTTDIND TYPE STRING,
TGTTDIND TYPE STRING,
PPTYP TYPE STRING,
BALANCE TYPE STRING,
PVFLAG TYPE STRING,
VERID TYPE STRING,
TODAT TYPE STRING,
FROMDAT TYPE STRING,
BOMALT TYPE STRING,
BOMUSE TYPE STRING,
BOMMAT TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
BLOIND TYPE STRING,
DELIND TYPE STRING,
TKTSELECT TYPE STRING,
TCONS TYPE STRING,
AUTOCONFIRM TYPE STRING,
VRMOD TYPE STRING,
VINT1 TYPE STRING,
VINT2 TYPE STRING,
DEFSITYP TYPE STRING,
DEFDOCIND TYPE STRING,
LBUOM TYPE STRING,
PMATNR_LONG TYPE STRING,
BOMMAT_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIJLOCMAT_N_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIJLOCMAT_N_STR-MANDT sy-vline
WA_OIJLOCMAT_N_STR-LOCID sy-vline
WA_OIJLOCMAT_N_STR-PMATNR sy-vline
WA_OIJLOCMAT_N_STR-LOCNAME sy-vline
WA_OIJLOCMAT_N_STR-PMATNAME sy-vline
WA_OIJLOCMAT_N_STR-PWERK sy-vline
WA_OIJLOCMAT_N_STR-CHARG sy-vline
WA_OIJLOCMAT_N_STR-RDUOM sy-vline
WA_OIJLOCMAT_N_STR-RDCONV sy-vline
WA_OIJLOCMAT_N_STR-PERIOD sy-vline
WA_OIJLOCMAT_N_STR-PAST sy-vline
WA_OIJLOCMAT_N_STR-TOLPCT sy-vline
WA_OIJLOCMAT_N_STR-TOLABS sy-vline
WA_OIJLOCMAT_N_STR-PASTDATA sy-vline
WA_OIJLOCMAT_N_STR-PHY_INV_FLG sy-vline
WA_OIJLOCMAT_N_STR-PHY_INV sy-vline
WA_OIJLOCMAT_N_STR-PHY_DATE sy-vline
WA_OIJLOCMAT_N_STR-FCPAST sy-vline
WA_OIJLOCMAT_N_STR-FCOFFSET sy-vline
WA_OIJLOCMAT_N_STR-FCTYPE sy-vline
WA_OIJLOCMAT_N_STR-PHYTMS sy-vline
WA_OIJLOCMAT_N_STR-SRCTYPE sy-vline
WA_OIJLOCMAT_N_STR-FCHORIZ sy-vline
WA_OIJLOCMAT_N_STR-RVP sy-vline
WA_OIJLOCMAT_N_STR-PLTYP sy-vline
WA_OIJLOCMAT_N_STR-CALFLG sy-vline
WA_OIJLOCMAT_N_STR-PLCAL sy-vline
WA_OIJLOCMAT_N_STR-COVER sy-vline
WA_OIJLOCMAT_N_STR-PLHOZ sy-vline
WA_OIJLOCMAT_N_STR-DATUOM sy-vline
WA_OIJLOCMAT_N_STR-PTSYST sy-vline
WA_OIJLOCMAT_N_STR-PLUOM sy-vline
WA_OIJLOCMAT_N_STR-CYCLE sy-vline
WA_OIJLOCMAT_N_STR-CYCUOM sy-vline
WA_OIJLOCMAT_N_STR-MAXLOT sy-vline
WA_OIJLOCMAT_N_STR-MINLOT sy-vline
WA_OIJLOCMAT_N_STR-INCLOT sy-vline
WA_OIJLOCMAT_N_STR-INVUOM sy-vline
WA_OIJLOCMAT_N_STR-MAXINV sy-vline
WA_OIJLOCMAT_N_STR-TARGET sy-vline
WA_OIJLOCMAT_N_STR-REORDER sy-vline
WA_OIJLOCMAT_N_STR-SAFETY sy-vline
WA_OIJLOCMAT_N_STR-UNPUMP sy-vline
WA_OIJLOCMAT_N_STR-MININV sy-vline
WA_OIJLOCMAT_N_STR-STSYST sy-vline
WA_OIJLOCMAT_N_STR-SLOCID sy-vline
WA_OIJLOCMAT_N_STR-SPART sy-vline
WA_OIJLOCMAT_N_STR-SPOBJ sy-vline
WA_OIJLOCMAT_N_STR-OFFPER sy-vline
WA_OIJLOCMAT_N_STR-OFFUOM sy-vline
WA_OIJLOCMAT_N_STR-RADIONOSRC sy-vline
WA_OIJLOCMAT_N_STR-RADIOTSSRC sy-vline
WA_OIJLOCMAT_N_STR-RADIOLOCSC sy-vline
WA_OIJLOCMAT_N_STR-PLANAMPEL sy-vline
WA_OIJLOCMAT_N_STR-PLANFLAG sy-vline
WA_OIJLOCMAT_N_STR-SCFLAG sy-vline
WA_OIJLOCMAT_N_STR-SERVICE sy-vline
WA_OIJLOCMAT_N_STR-COVPROF sy-vline
WA_OIJLOCMAT_N_STR-CALPROF sy-vline
WA_OIJLOCMAT_N_STR-FACTORY sy-vline
WA_OIJLOCMAT_N_STR-SFTTYPE sy-vline
WA_OIJLOCMAT_N_STR-HISTHOZ sy-vline
WA_OIJLOCMAT_N_STR-TSERVICE sy-vline
WA_OIJLOCMAT_N_STR-TCOVPROF sy-vline
WA_OIJLOCMAT_N_STR-TCALPROF sy-vline
WA_OIJLOCMAT_N_STR-TFACTORY sy-vline
WA_OIJLOCMAT_N_STR-TGTTYPE sy-vline
WA_OIJLOCMAT_N_STR-THISTHOZ sy-vline
WA_OIJLOCMAT_N_STR-FCCAL sy-vline
WA_OIJLOCMAT_N_STR-FCPRF sy-vline
WA_OIJLOCMAT_N_STR-TANKUPD sy-vline
WA_OIJLOCMAT_N_STR-SFTLVL sy-vline
WA_OIJLOCMAT_N_STR-HRLVL sy-vline
WA_OIJLOCMAT_N_STR-SFTTDIND sy-vline
WA_OIJLOCMAT_N_STR-TGTTDIND sy-vline
WA_OIJLOCMAT_N_STR-PPTYP sy-vline
WA_OIJLOCMAT_N_STR-BALANCE sy-vline
WA_OIJLOCMAT_N_STR-PVFLAG sy-vline
WA_OIJLOCMAT_N_STR-VERID sy-vline
WA_OIJLOCMAT_N_STR-TODAT sy-vline
WA_OIJLOCMAT_N_STR-FROMDAT sy-vline
WA_OIJLOCMAT_N_STR-BOMALT sy-vline
WA_OIJLOCMAT_N_STR-BOMUSE sy-vline
WA_OIJLOCMAT_N_STR-BOMMAT sy-vline
WA_OIJLOCMAT_N_STR-ERDAT sy-vline
WA_OIJLOCMAT_N_STR-ERZEIT sy-vline
WA_OIJLOCMAT_N_STR-ERNAM sy-vline
WA_OIJLOCMAT_N_STR-AEDAT sy-vline
WA_OIJLOCMAT_N_STR-AEZEIT sy-vline
WA_OIJLOCMAT_N_STR-AENAM sy-vline
WA_OIJLOCMAT_N_STR-BLOIND sy-vline
WA_OIJLOCMAT_N_STR-DELIND sy-vline
WA_OIJLOCMAT_N_STR-TKTSELECT sy-vline
WA_OIJLOCMAT_N_STR-TCONS sy-vline
WA_OIJLOCMAT_N_STR-AUTOCONFIRM sy-vline
WA_OIJLOCMAT_N_STR-VRMOD sy-vline
WA_OIJLOCMAT_N_STR-VINT1 sy-vline
WA_OIJLOCMAT_N_STR-VINT2 sy-vline
WA_OIJLOCMAT_N_STR-DEFSITYP sy-vline
WA_OIJLOCMAT_N_STR-DEFDOCIND sy-vline
WA_OIJLOCMAT_N_STR-LBUOM sy-vline
WA_OIJLOCMAT_N_STR-PMATNR_LONG sy-vline
WA_OIJLOCMAT_N_STR-BOMMAT_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.