ABAP Select data from SAP table OIJTHPUTFC_SIM into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIJTHPUTFC_SIM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIJTHPUTFC_SIM. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIJTHPUTFC_SIM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIJTHPUTFC_SIM TYPE STANDARD TABLE OF OIJTHPUTFC_SIM, WA_OIJTHPUTFC_SIM TYPE OIJTHPUTFC_SIM, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIJTHPUTFC_SIM> TYPE OIJTHPUTFC_SIM. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIJTHPUTFC_SIM. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIJTHPUTFC_SIM INTO TABLE IT_OIJTHPUTFC_SIM. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIJTHPUTFC_SIM * INTO TABLE @DATA(IT_OIJTHPUTFC_SIM2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIJTHPUTFC_SIM INDEX 1 INTO DATA(WA_OIJTHPUTFC_SIM2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIJTHPUTFC_SIM ASSIGNING <OIJTHPUTFC_SIM>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIJTHPUTFC_SIM>-MANDT = 1.
<OIJTHPUTFC_SIM>-LOCID = 1.
<OIJTHPUTFC_SIM>-SOCNR = 1.
<OIJTHPUTFC_SIM>-MATNR = 1.
<OIJTHPUTFC_SIM>-CHARG = 1.
ENDLOOP. LOOP AT IT_OIJTHPUTFC_SIM INTO WA_OIJTHPUTFC_SIM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIJTHPUTFC_SIM-DATUM, sy-vline,
WA_OIJTHPUTFC_SIM-VKTRA, sy-vline,
WA_OIJTHPUTFC_SIM-FCTYPE, sy-vline,
WA_OIJTHPUTFC_SIM-CUFCTYPE, sy-vline,
WA_OIJTHPUTFC_SIM-THPFCIND, sy-vline,
WA_OIJTHPUTFC_SIM-SCENARIO_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIJTHPUTFC_SIM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIJTHPUTFC_SIM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIJTHPUTFC_SIM INTO WA_OIJTHPUTFC_SIM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIJTHPUTFC_SIM-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJTHPUTFC_SIM-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field THPUTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJTHPUTFC_SIM-THPUTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJTHPUTFC_SIM-THPUTUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIJTHPUTFC_SIM_STR,
MANDT TYPE STRING,
LOCID TYPE STRING,
SOCNR TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
DATUM TYPE STRING,
VKTRA TYPE STRING,
FCTYPE TYPE STRING,
CUFCTYPE TYPE STRING,
THPFCIND TYPE STRING,
SCENARIO_ID TYPE STRING,
SIM_VERSION TYPE STRING,
THPUT TYPE STRING,
THPUTUOM TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
UPDKZ TYPE STRING,
USER_ID TYPE STRING,
SCHED_STAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIJTHPUTFC_SIM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIJTHPUTFC_SIM_STR-MANDT sy-vline
WA_OIJTHPUTFC_SIM_STR-LOCID sy-vline
WA_OIJTHPUTFC_SIM_STR-SOCNR sy-vline
WA_OIJTHPUTFC_SIM_STR-MATNR sy-vline
WA_OIJTHPUTFC_SIM_STR-CHARG sy-vline
WA_OIJTHPUTFC_SIM_STR-DATUM sy-vline
WA_OIJTHPUTFC_SIM_STR-VKTRA sy-vline
WA_OIJTHPUTFC_SIM_STR-FCTYPE sy-vline
WA_OIJTHPUTFC_SIM_STR-CUFCTYPE sy-vline
WA_OIJTHPUTFC_SIM_STR-THPFCIND sy-vline
WA_OIJTHPUTFC_SIM_STR-SCENARIO_ID sy-vline
WA_OIJTHPUTFC_SIM_STR-SIM_VERSION sy-vline
WA_OIJTHPUTFC_SIM_STR-THPUT sy-vline
WA_OIJTHPUTFC_SIM_STR-THPUTUOM sy-vline
WA_OIJTHPUTFC_SIM_STR-ERDAT sy-vline
WA_OIJTHPUTFC_SIM_STR-ERZEIT sy-vline
WA_OIJTHPUTFC_SIM_STR-ERNAM sy-vline
WA_OIJTHPUTFC_SIM_STR-AEDAT sy-vline
WA_OIJTHPUTFC_SIM_STR-AEZEIT sy-vline
WA_OIJTHPUTFC_SIM_STR-AENAM sy-vline
WA_OIJTHPUTFC_SIM_STR-UPDKZ sy-vline
WA_OIJTHPUTFC_SIM_STR-USER_ID sy-vline
WA_OIJTHPUTFC_SIM_STR-SCHED_STAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.