ABAP Select data from SAP table OIU_CM_SN_NR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIU_CM_SN_NR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIU_CM_SN_NR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIU_CM_SN_NR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIU_CM_SN_NR TYPE STANDARD TABLE OF OIU_CM_SN_NR, WA_OIU_CM_SN_NR TYPE OIU_CM_SN_NR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIU_CM_SN_NR> TYPE OIU_CM_SN_NR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIU_CM_SN_NR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIU_CM_SN_NR INTO TABLE IT_OIU_CM_SN_NR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIU_CM_SN_NR * INTO TABLE @DATA(IT_OIU_CM_SN_NR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIU_CM_SN_NR INDEX 1 INTO DATA(WA_OIU_CM_SN_NR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIU_CM_SN_NR ASSIGNING <OIU_CM_SN_NR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIU_CM_SN_NR>-TABNAME = 1.
<OIU_CM_SN_NR>-EXTERNIND = 1.
<OIU_CM_SN_NR>-NR_OBJECT = 1.
<OIU_CM_SN_NR>-SYSTEM_NRIV = 1.
<OIU_CM_SN_NR>-SUGGESTED_FROM = 1.
ENDLOOP. LOOP AT IT_OIU_CM_SN_NR INTO WA_OIU_CM_SN_NR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIU_CM_SN_NR-SUGGESTED_TO, sy-vline,
WA_OIU_CM_SN_NR-CONDITIONAL, sy-vline,
WA_OIU_CM_SN_NR-COND_PROGRAM, sy-vline,
WA_OIU_CM_SN_NR-COND_FORM, sy-vline,
WA_OIU_CM_SN_NR-IMG_SUBOBJECT, sy-vline,
ENDLOOP. *Add any further fields from structure WA_OIU_CM_SN_NR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIU_CM_SN_NR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIU_CM_SN_NR INTO WA_OIU_CM_SN_NR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIU_CM_SN_NR_STR,
TABNAME TYPE STRING,
EXTERNIND TYPE STRING,
NR_OBJECT TYPE STRING,
SYSTEM_NRIV TYPE STRING,
SUGGESTED_FROM TYPE STRING,
SUGGESTED_TO TYPE STRING,
CONDITIONAL TYPE STRING,
COND_PROGRAM TYPE STRING,
COND_FORM TYPE STRING,
IMG_SUBOBJECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIU_CM_SN_NR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIU_CM_SN_NR_STR-TABNAME sy-vline
WA_OIU_CM_SN_NR_STR-EXTERNIND sy-vline
WA_OIU_CM_SN_NR_STR-NR_OBJECT sy-vline
WA_OIU_CM_SN_NR_STR-SYSTEM_NRIV sy-vline
WA_OIU_CM_SN_NR_STR-SUGGESTED_FROM sy-vline
WA_OIU_CM_SN_NR_STR-SUGGESTED_TO sy-vline
WA_OIU_CM_SN_NR_STR-CONDITIONAL sy-vline
WA_OIU_CM_SN_NR_STR-COND_PROGRAM sy-vline
WA_OIU_CM_SN_NR_STR-COND_FORM sy-vline
WA_OIU_CM_SN_NR_STR-IMG_SUBOBJECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.