ABAP Select data from SAP table OIU_ENP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIU_ENP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIU_ENP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIU_ENP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIU_ENP TYPE STANDARD TABLE OF OIU_ENP, WA_OIU_ENP TYPE OIU_ENP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIU_ENP> TYPE OIU_ENP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIU_ENP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIU_ENP INTO TABLE IT_OIU_ENP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIU_ENP * INTO TABLE @DATA(IT_OIU_ENP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIU_ENP INDEX 1 INTO DATA(WA_OIU_ENP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIU_ENP ASSIGNING <OIU_ENP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIU_ENP>-OIU_WL_NO = 1.
<OIU_ENP>-OIU_WC_NO = 1.
<OIU_ENP>-OIU_DN_NO = 1.
<OIU_ENP>-OIU_MP_NO = 1.
<OIU_ENP>-OIU_RUN_TKT_NO = 1.
ENDLOOP. LOOP AT IT_OIU_ENP INTO WA_OIU_ENP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIU_ENP-OIU_MAJPD_CD, sy-vline,
WA_OIU_ENP-OIU_A_H_VAL_FCT, sy-vline,
WA_OIU_ENP-OIU_A_H_VAL_F_U, sy-vline,
WA_OIU_ENP-OIU_GRV_AM, sy-vline,
WA_OIU_ENP-OIU_DENSITY_U, sy-vline,
WA_OIU_ENP-OIU_TRNSP_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIU_ENP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIU_ENP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIU_ENP INTO WA_OIU_ENP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field OIU_WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_DN_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_MP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field OIU_A_H_VAL_F_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_A_H_VAL_F_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_A_H_VAL_F_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field OIU_DENSITY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_DENSITY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_DENSITY_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_TRNSP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_ORIG_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_ORIG_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_ORIG_MP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_PR_WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_PR_WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_PR_WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_PR_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_PR_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_PR_MP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_PR_WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_PR_WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_PR_WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OIU_DOI_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_ENP-OIU_DOI_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_ENP-OIU_DOI_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIU_ENP_STR,
OIU_WL_NO TYPE STRING,
OIU_WC_NO TYPE STRING,
OIU_DN_NO TYPE STRING,
OIU_MP_NO TYPE STRING,
OIU_RUN_TKT_NO TYPE STRING,
OIU_MAJPD_CD TYPE STRING,
OIU_A_H_VAL_FCT TYPE STRING,
OIU_A_H_VAL_F_U TYPE STRING,
OIU_GRV_AM TYPE STRING,
OIU_DENSITY_U TYPE STRING,
OIU_TRNSP_NO TYPE STRING,
OIU_TRNSP_REF_NO TYPE STRING,
OIU_SALE_DT_FROM TYPE STRING,
OIU_SALE_DT_TO TYPE STRING,
OIU_ORIG_MP_NO TYPE STRING,
OIU_PR_WC_NO TYPE STRING,
OIU_PR_MP_NO TYPE STRING,
OIU_PR_WL_NO TYPE STRING,
OIU_VNAME TYPE STRING,
OIU_FREQ_CD TYPE STRING,
OIU_DOI_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIU_ENP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIU_ENP_STR-OIU_WL_NO sy-vline
WA_OIU_ENP_STR-OIU_WC_NO sy-vline
WA_OIU_ENP_STR-OIU_DN_NO sy-vline
WA_OIU_ENP_STR-OIU_MP_NO sy-vline
WA_OIU_ENP_STR-OIU_RUN_TKT_NO sy-vline
WA_OIU_ENP_STR-OIU_MAJPD_CD sy-vline
WA_OIU_ENP_STR-OIU_A_H_VAL_FCT sy-vline
WA_OIU_ENP_STR-OIU_A_H_VAL_F_U sy-vline
WA_OIU_ENP_STR-OIU_GRV_AM sy-vline
WA_OIU_ENP_STR-OIU_DENSITY_U sy-vline
WA_OIU_ENP_STR-OIU_TRNSP_NO sy-vline
WA_OIU_ENP_STR-OIU_TRNSP_REF_NO sy-vline
WA_OIU_ENP_STR-OIU_SALE_DT_FROM sy-vline
WA_OIU_ENP_STR-OIU_SALE_DT_TO sy-vline
WA_OIU_ENP_STR-OIU_ORIG_MP_NO sy-vline
WA_OIU_ENP_STR-OIU_PR_WC_NO sy-vline
WA_OIU_ENP_STR-OIU_PR_MP_NO sy-vline
WA_OIU_ENP_STR-OIU_PR_WL_NO sy-vline
WA_OIU_ENP_STR-OIU_VNAME sy-vline
WA_OIU_ENP_STR-OIU_FREQ_CD sy-vline
WA_OIU_ENP_STR-OIU_DOI_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.