ABAP Select data from SAP table OIUBL01_PBADOI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUBL01_PBADOI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUBL01_PBADOI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUBL01_PBADOI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUBL01_PBADOI TYPE STANDARD TABLE OF OIUBL01_PBADOI,
      WA_OIUBL01_PBADOI TYPE OIUBL01_PBADOI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUBL01_PBADOI> TYPE OIUBL01_PBADOI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUBL01_PBADOI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUBL01_PBADOI
  INTO TABLE IT_OIUBL01_PBADOI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUBL01_PBADOI
*  INTO TABLE @DATA(IT_OIUBL01_PBADOI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUBL01_PBADOI INDEX 1 INTO DATA(WA_OIUBL01_PBADOI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUBL01_PBADOI ASSIGNING <OIUBL01_PBADOI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUBL01_PBADOI>-MANDT = 1.
<OIUBL01_PBADOI>-PBA_NO = 1.
<OIUBL01_PBADOI>-WL_NO = 1.
<OIUBL01_PBADOI>-WC_NO = 1.
<OIUBL01_PBADOI>-MP_NO = 1.
ENDLOOP.

LOOP AT IT_OIUBL01_PBADOI INTO WA_OIUBL01_PBADOI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUBL01_PBADOI-RPT_MO, sy-vline,
WA_OIUBL01_PBADOI-BUKRS, sy-vline,
WA_OIUBL01_PBADOI-VNAME, sy-vline,
WA_OIUBL01_PBADOI-DOI_NO, sy-vline,
WA_OIUBL01_PBADOI-OWN_NO, sy-vline,
WA_OIUBL01_PBADOI-OWN_INT_TYPE_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUBL01_PBADOI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUBL01_PBADOI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUBL01_PBADOI INTO WA_OIUBL01_PBADOI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PBA_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-PBA_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-PBA_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-WL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-WC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOI_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-DOI_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-DOI_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-OWN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-OWN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWN_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUBL01_PBADOI-OWN_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUBL01_PBADOI-OWN_ISQ_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUBL01_PBADOI_STR,
MANDT TYPE STRING,
PBA_NO TYPE STRING,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
MP_NO TYPE STRING,
RPT_MO TYPE STRING,
BUKRS TYPE STRING,
VNAME TYPE STRING,
DOI_NO TYPE STRING,
OWN_NO TYPE STRING,
OWN_INT_TYPE_CD TYPE STRING,
OWN_ISQ_NO TYPE STRING,
GRI_PC TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUBL01_PBADOI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUBL01_PBADOI_STR-MANDT sy-vline
WA_OIUBL01_PBADOI_STR-PBA_NO sy-vline
WA_OIUBL01_PBADOI_STR-WL_NO sy-vline
WA_OIUBL01_PBADOI_STR-WC_NO sy-vline
WA_OIUBL01_PBADOI_STR-MP_NO sy-vline
WA_OIUBL01_PBADOI_STR-RPT_MO sy-vline
WA_OIUBL01_PBADOI_STR-BUKRS sy-vline
WA_OIUBL01_PBADOI_STR-VNAME sy-vline
WA_OIUBL01_PBADOI_STR-DOI_NO sy-vline
WA_OIUBL01_PBADOI_STR-OWN_NO sy-vline
WA_OIUBL01_PBADOI_STR-OWN_INT_TYPE_CD sy-vline
WA_OIUBL01_PBADOI_STR-OWN_ISQ_NO sy-vline
WA_OIUBL01_PBADOI_STR-GRI_PC sy-vline
WA_OIUBL01_PBADOI_STR-OIU_CRUSER sy-vline
WA_OIUBL01_PBADOI_STR-OIU_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.