ABAP Select data from SAP table OIUGR_ROYSTG_PR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUGR_ROYSTG_PR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUGR_ROYSTG_PR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIUGR_ROYSTG_PR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIUGR_ROYSTG_PR TYPE STANDARD TABLE OF OIUGR_ROYSTG_PR, WA_OIUGR_ROYSTG_PR TYPE OIUGR_ROYSTG_PR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIUGR_ROYSTG_PR> TYPE OIUGR_ROYSTG_PR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIUGR_ROYSTG_PR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIUGR_ROYSTG_PR INTO TABLE IT_OIUGR_ROYSTG_PR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIUGR_ROYSTG_PR * INTO TABLE @DATA(IT_OIUGR_ROYSTG_PR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIUGR_ROYSTG_PR INDEX 1 INTO DATA(WA_OIUGR_ROYSTG_PR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIUGR_ROYSTG_PR ASSIGNING <OIUGR_ROYSTG_PR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUGR_ROYSTG_PR>-MANDT = 1.
<OIUGR_ROYSTG_PR>-ROYTXN_PR_GUID = 1.
<OIUGR_ROYSTG_PR>-PRD_MATNR = 1.
<OIUGR_ROYSTG_PR>-MATNR = 1.
<OIUGR_ROYSTG_PR>-VT_CD = 1.
ENDLOOP. LOOP AT IT_OIUGR_ROYSTG_PR INTO WA_OIUGR_ROYSTG_PR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIUGR_ROYSTG_PR-VC_CD, sy-vline,
WA_OIUGR_ROYSTG_PR-PROC_ID, sy-vline,
WA_OIUGR_ROYSTG_PR-SALES_DT, sy-vline,
WA_OIUGR_ROYSTG_PR-DERIVED_WL_NO, sy-vline,
WA_OIUGR_ROYSTG_PR-DERIVED_WC_NO, sy-vline,
WA_OIUGR_ROYSTG_PR-STD_VOL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUGR_ROYSTG_PR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUGR_ROYSTG_PR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUGR_ROYSTG_PR INTO WA_OIUGR_ROYSTG_PR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field PRD_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-PRD_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-PRD_MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DERIVED_WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-DERIVED_WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-DERIVED_WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DERIVED_WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-DERIVED_WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-DERIVED_WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field STD_VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-STD_VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-STD_VOL_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-ENERGY_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field HEAT_VAL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUGR_ROYSTG_PR-HEAT_VAL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUGR_ROYSTG_PR-HEAT_VAL_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUGR_ROYSTG_PR_STR,
MANDT TYPE STRING,
ROYTXN_PR_GUID TYPE STRING,
PRD_MATNR TYPE STRING,
MATNR TYPE STRING,
VT_CD TYPE STRING,
VC_CD TYPE STRING,
PROC_ID TYPE STRING,
SALES_DT TYPE STRING,
DERIVED_WL_NO TYPE STRING,
DERIVED_WC_NO TYPE STRING,
STD_VOL TYPE STRING,
STD_VOL_U TYPE STRING,
ENERGY TYPE STRING,
ENERGY_U TYPE STRING,
HEAT_VAL TYPE STRING,
HEAT_VAL_U TYPE STRING,
DAYS_PROD TYPE STRING,
PRD_HRS TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUGR_ROYSTG_PR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUGR_ROYSTG_PR_STR-MANDT sy-vline
WA_OIUGR_ROYSTG_PR_STR-ROYTXN_PR_GUID sy-vline
WA_OIUGR_ROYSTG_PR_STR-PRD_MATNR sy-vline
WA_OIUGR_ROYSTG_PR_STR-MATNR sy-vline
WA_OIUGR_ROYSTG_PR_STR-VT_CD sy-vline
WA_OIUGR_ROYSTG_PR_STR-VC_CD sy-vline
WA_OIUGR_ROYSTG_PR_STR-PROC_ID sy-vline
WA_OIUGR_ROYSTG_PR_STR-SALES_DT sy-vline
WA_OIUGR_ROYSTG_PR_STR-DERIVED_WL_NO sy-vline
WA_OIUGR_ROYSTG_PR_STR-DERIVED_WC_NO sy-vline
WA_OIUGR_ROYSTG_PR_STR-STD_VOL sy-vline
WA_OIUGR_ROYSTG_PR_STR-STD_VOL_U sy-vline
WA_OIUGR_ROYSTG_PR_STR-ENERGY sy-vline
WA_OIUGR_ROYSTG_PR_STR-ENERGY_U sy-vline
WA_OIUGR_ROYSTG_PR_STR-HEAT_VAL sy-vline
WA_OIUGR_ROYSTG_PR_STR-HEAT_VAL_U sy-vline
WA_OIUGR_ROYSTG_PR_STR-DAYS_PROD sy-vline
WA_OIUGR_ROYSTG_PR_STR-PRD_HRS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.