ABAP Select data from SAP table OIUH_RV_PR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUH_RV_PR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUH_RV_PR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUH_RV_PR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUH_RV_PR TYPE STANDARD TABLE OF OIUH_RV_PR,
      WA_OIUH_RV_PR TYPE OIUH_RV_PR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUH_RV_PR> TYPE OIUH_RV_PR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUH_RV_PR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUH_RV_PR
  INTO TABLE IT_OIUH_RV_PR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUH_RV_PR
*  INTO TABLE @DATA(IT_OIUH_RV_PR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUH_RV_PR INDEX 1 INTO DATA(WA_OIUH_RV_PR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUH_RV_PR ASSIGNING <OIUH_RV_PR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUH_RV_PR>-MANDT = 1.
<OIUH_RV_PR>-PR_PR_NO = 1.
<OIUH_RV_PR>-PR_PR_INT_CD = 1.
<OIUH_RV_PR>-PR_PR_NM9 = 1.
<OIUH_RV_PR>-PR_PR_NM = 1.
ENDLOOP.

LOOP AT IT_OIUH_RV_PR INTO WA_OIUH_RV_PR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUH_RV_PR-PR_OP_NO9, sy-vline,
WA_OIUH_RV_PR-PR_OP_NO, sy-vline,
WA_OIUH_RV_PR-PR_OP_SEQ_NO9, sy-vline,
WA_OIUH_RV_PR-PR_OP_SEQ_NO, sy-vline,
WA_OIUH_RV_PR-PR_STS_CD, sy-vline,
WA_OIUH_RV_PR-PR_STS_EFF_DT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUH_RV_PR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUH_RV_PR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUH_RV_PR INTO WA_OIUH_RV_PR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUH_RV_PR_STR,
MANDT TYPE STRING,
PR_PR_NO TYPE STRING,
PR_PR_INT_CD TYPE STRING,
PR_PR_NM9 TYPE STRING,
PR_PR_NM TYPE STRING,
PR_OP_NO9 TYPE STRING,
PR_OP_NO TYPE STRING,
PR_OP_SEQ_NO9 TYPE STRING,
PR_OP_SEQ_NO TYPE STRING,
PR_STS_CD TYPE STRING,
PR_STS_EFF_DT TYPE STRING,
PR_STATE_NO TYPE STRING,
PR_CMT_FL TYPE STRING,
PR_COUNTY_NO TYPE STRING,
PR_CNTRY_NO TYPE STRING,
PR_ACQ_DT9 TYPE STRING,
PR_ACQ_DT TYPE STRING,
PR_OR_LVL_1_NO TYPE STRING,
PR_TYPE_CD TYPE STRING,
PR_OLD_PR_NO TYPE STRING,
PR_UNIT_FL TYPE STRING,
PR_DOI_BY_TR_FL TYPE STRING,
PR_DRL_FUND_FL TYPE STRING,
PR_ONS_OFS_CD TYPE STRING,
ACQ_FROM_BA_NO9 TYPE STRING,
ACQ_FROM_BA_NO TYPE STRING,
R_ACQ_BA_SEQ_NO9 TYPE STRING,
R_ACQ_BA_SEQ_NO TYPE STRING,
PR_SLD_TO_BA_NO9 TYPE STRING,
PR_SLD_TO_BA_NO TYPE STRING,
R_SLD_BA_SEQ_NO9 TYPE STRING,
R_SLD_BA_SEQ_NO TYPE STRING,
R_AFFIL_CO_1_NO9 TYPE STRING,
R_AFFIL_CO_1_NO TYPE STRING,
R_AFFIL_CO_2_NO9 TYPE STRING,
R_AFFIL_CO_2_NO TYPE STRING,
R_AFFIL_CO_3_NO9 TYPE STRING,
R_AFFIL_CO_3_NO TYPE STRING,
R_AFFIL_CO_4_NO9 TYPE STRING,
R_AFFIL_CO_4_NO TYPE STRING,
R_AFFIL_CO_5_NO9 TYPE STRING,
R_AFFIL_CO_5_NO TYPE STRING,
R_LEG_DE_CMT_FL TYPE STRING,
PR_SPACE_ORD_NO TYPE STRING,
PR_LPN_NO TYPE STRING,
PR_DOI_PRT_FL TYPE STRING,
PR_FL_NO TYPE STRING,
PR_CHV_RPT_CD TYPE STRING,
PR_VER_NO TYPE STRING,
PR_USER_ID TYPE STRING,
PR_TIMESTAMP TYPE STRING,
PROPERTY_KEY9 TYPE STRING,
PROPERTY_KEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUH_RV_PR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUH_RV_PR_STR-MANDT sy-vline
WA_OIUH_RV_PR_STR-PR_PR_NO sy-vline
WA_OIUH_RV_PR_STR-PR_PR_INT_CD sy-vline
WA_OIUH_RV_PR_STR-PR_PR_NM9 sy-vline
WA_OIUH_RV_PR_STR-PR_PR_NM sy-vline
WA_OIUH_RV_PR_STR-PR_OP_NO9 sy-vline
WA_OIUH_RV_PR_STR-PR_OP_NO sy-vline
WA_OIUH_RV_PR_STR-PR_OP_SEQ_NO9 sy-vline
WA_OIUH_RV_PR_STR-PR_OP_SEQ_NO sy-vline
WA_OIUH_RV_PR_STR-PR_STS_CD sy-vline
WA_OIUH_RV_PR_STR-PR_STS_EFF_DT sy-vline
WA_OIUH_RV_PR_STR-PR_STATE_NO sy-vline
WA_OIUH_RV_PR_STR-PR_CMT_FL sy-vline
WA_OIUH_RV_PR_STR-PR_COUNTY_NO sy-vline
WA_OIUH_RV_PR_STR-PR_CNTRY_NO sy-vline
WA_OIUH_RV_PR_STR-PR_ACQ_DT9 sy-vline
WA_OIUH_RV_PR_STR-PR_ACQ_DT sy-vline
WA_OIUH_RV_PR_STR-PR_OR_LVL_1_NO sy-vline
WA_OIUH_RV_PR_STR-PR_TYPE_CD sy-vline
WA_OIUH_RV_PR_STR-PR_OLD_PR_NO sy-vline
WA_OIUH_RV_PR_STR-PR_UNIT_FL sy-vline
WA_OIUH_RV_PR_STR-PR_DOI_BY_TR_FL sy-vline
WA_OIUH_RV_PR_STR-PR_DRL_FUND_FL sy-vline
WA_OIUH_RV_PR_STR-PR_ONS_OFS_CD sy-vline
WA_OIUH_RV_PR_STR-ACQ_FROM_BA_NO9 sy-vline
WA_OIUH_RV_PR_STR-ACQ_FROM_BA_NO sy-vline
WA_OIUH_RV_PR_STR-R_ACQ_BA_SEQ_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_ACQ_BA_SEQ_NO sy-vline
WA_OIUH_RV_PR_STR-PR_SLD_TO_BA_NO9 sy-vline
WA_OIUH_RV_PR_STR-PR_SLD_TO_BA_NO sy-vline
WA_OIUH_RV_PR_STR-R_SLD_BA_SEQ_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_SLD_BA_SEQ_NO sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_1_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_1_NO sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_2_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_2_NO sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_3_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_3_NO sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_4_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_4_NO sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_5_NO9 sy-vline
WA_OIUH_RV_PR_STR-R_AFFIL_CO_5_NO sy-vline
WA_OIUH_RV_PR_STR-R_LEG_DE_CMT_FL sy-vline
WA_OIUH_RV_PR_STR-PR_SPACE_ORD_NO sy-vline
WA_OIUH_RV_PR_STR-PR_LPN_NO sy-vline
WA_OIUH_RV_PR_STR-PR_DOI_PRT_FL sy-vline
WA_OIUH_RV_PR_STR-PR_FL_NO sy-vline
WA_OIUH_RV_PR_STR-PR_CHV_RPT_CD sy-vline
WA_OIUH_RV_PR_STR-PR_VER_NO sy-vline
WA_OIUH_RV_PR_STR-PR_USER_ID sy-vline
WA_OIUH_RV_PR_STR-PR_TIMESTAMP sy-vline
WA_OIUH_RV_PR_STR-PROPERTY_KEY9 sy-vline
WA_OIUH_RV_PR_STR-PROPERTY_KEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.