ABAP Select data from SAP table OIUP_SB_ACTMP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUP_SB_ACTMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUP_SB_ACTMP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIUP_SB_ACTMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIUP_SB_ACTMP TYPE STANDARD TABLE OF OIUP_SB_ACTMP, WA_OIUP_SB_ACTMP TYPE OIUP_SB_ACTMP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIUP_SB_ACTMP> TYPE OIUP_SB_ACTMP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIUP_SB_ACTMP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIUP_SB_ACTMP INTO TABLE IT_OIUP_SB_ACTMP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIUP_SB_ACTMP * INTO TABLE @DATA(IT_OIUP_SB_ACTMP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIUP_SB_ACTMP INDEX 1 INTO DATA(WA_OIUP_SB_ACTMP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIUP_SB_ACTMP ASSIGNING <OIUP_SB_ACTMP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUP_SB_ACTMP>-MANDT = 1.
<OIUP_SB_ACTMP>-PDM_GUID = 1.
<OIUP_SB_ACTMP>-DN_NO = 1.
<OIUP_SB_ACTMP>-MP_NO = 1.
<OIUP_SB_ACTMP>-MATNR = 1.
ENDLOOP. LOOP AT IT_OIUP_SB_ACTMP INTO WA_OIUP_SB_ACTMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIUP_SB_ACTMP-CT_NO, sy-vline,
WA_OIUP_SB_ACTMP-SA_DT, sy-vline,
WA_OIUP_SB_ACTMP-OWN_NO, sy-vline,
WA_OIUP_SB_ACTMP-OWN_INT_TYPE_CD, sy-vline,
WA_OIUP_SB_ACTMP-OWN_ISQ_NO, sy-vline,
WA_OIUP_SB_ACTMP-ORIG_MP_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUP_SB_ACTMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUP_SB_ACTMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUP_SB_ACTMP INTO WA_OIUP_SB_ACTMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-DN_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-MP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CT_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-CT_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-CT_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-OWN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-OWN_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWN_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-OWN_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-OWN_ISQ_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ORIG_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-ORIG_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-ORIG_MP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ACTL_VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-ACTL_VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-ACTL_VOL_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field HEAT_VAL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-HEAT_VAL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-HEAT_VAL_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ACTL_ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUP_SB_ACTMP-ACTL_ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUP_SB_ACTMP-ACTL_ENERGY_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUP_SB_ACTMP_STR,
MANDT TYPE STRING,
PDM_GUID TYPE STRING,
DN_NO TYPE STRING,
MP_NO TYPE STRING,
MATNR TYPE STRING,
CT_NO TYPE STRING,
SA_DT TYPE STRING,
OWN_NO TYPE STRING,
OWN_INT_TYPE_CD TYPE STRING,
OWN_ISQ_NO TYPE STRING,
ORIG_MP_NO TYPE STRING,
TRNSP_NO TYPE STRING,
FREQ_CD TYPE STRING,
ACTL_VOL_U TYPE STRING,
ACTL_VOL TYPE STRING,
HEAT_VAL_U TYPE STRING,
HEAT_VAL TYPE STRING,
ACTL_ENERGY_U TYPE STRING,
ACTL_ENERGY TYPE STRING,
WG_OVRD_PC TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUP_SB_ACTMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUP_SB_ACTMP_STR-MANDT sy-vline
WA_OIUP_SB_ACTMP_STR-PDM_GUID sy-vline
WA_OIUP_SB_ACTMP_STR-DN_NO sy-vline
WA_OIUP_SB_ACTMP_STR-MP_NO sy-vline
WA_OIUP_SB_ACTMP_STR-MATNR sy-vline
WA_OIUP_SB_ACTMP_STR-CT_NO sy-vline
WA_OIUP_SB_ACTMP_STR-SA_DT sy-vline
WA_OIUP_SB_ACTMP_STR-OWN_NO sy-vline
WA_OIUP_SB_ACTMP_STR-OWN_INT_TYPE_CD sy-vline
WA_OIUP_SB_ACTMP_STR-OWN_ISQ_NO sy-vline
WA_OIUP_SB_ACTMP_STR-ORIG_MP_NO sy-vline
WA_OIUP_SB_ACTMP_STR-TRNSP_NO sy-vline
WA_OIUP_SB_ACTMP_STR-FREQ_CD sy-vline
WA_OIUP_SB_ACTMP_STR-ACTL_VOL_U sy-vline
WA_OIUP_SB_ACTMP_STR-ACTL_VOL sy-vline
WA_OIUP_SB_ACTMP_STR-HEAT_VAL_U sy-vline
WA_OIUP_SB_ACTMP_STR-HEAT_VAL sy-vline
WA_OIUP_SB_ACTMP_STR-ACTL_ENERGY_U sy-vline
WA_OIUP_SB_ACTMP_STR-ACTL_ENERGY sy-vline
WA_OIUP_SB_ACTMP_STR-WG_OVRD_PC sy-vline
WA_OIUP_SB_ACTMP_STR-OIU_CRUSER sy-vline
WA_OIUP_SB_ACTMP_STR-OIU_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.