ABAP Select data from SAP table OIUREP_EIA_HSTDT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUREP_EIA_HSTDT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUREP_EIA_HSTDT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIUREP_EIA_HSTDT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIUREP_EIA_HSTDT TYPE STANDARD TABLE OF OIUREP_EIA_HSTDT, WA_OIUREP_EIA_HSTDT TYPE OIUREP_EIA_HSTDT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIUREP_EIA_HSTDT> TYPE OIUREP_EIA_HSTDT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIUREP_EIA_HSTDT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIUREP_EIA_HSTDT INTO TABLE IT_OIUREP_EIA_HSTDT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIUREP_EIA_HSTDT * INTO TABLE @DATA(IT_OIUREP_EIA_HSTDT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIUREP_EIA_HSTDT INDEX 1 INTO DATA(WA_OIUREP_EIA_HSTDT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIUREP_EIA_HSTDT ASSIGNING <OIUREP_EIA_HSTDT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUREP_EIA_HSTDT>-MANDT = 1.
<OIUREP_EIA_HSTDT>-EIAHSTDT_UUID = 1.
<OIUREP_EIA_HSTDT>-REG_NUMBER = 1.
<OIUREP_EIA_HSTDT>-PRI_GEO_LOC = 1.
<OIUREP_EIA_HSTDT>-RPT_COLUMN = 1.
ENDLOOP. LOOP AT IT_OIUREP_EIA_HSTDT INTO WA_OIUREP_EIA_HSTDT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIUREP_EIA_HSTDT-STD_VOL, sy-vline,
WA_OIUREP_EIA_HSTDT-BASE_DENSITY, sy-vline,
WA_OIUREP_EIA_HSTDT-VARIANCE, sy-vline,
WA_OIUREP_EIA_HSTDT-COMMENT_21, sy-vline,
WA_OIUREP_EIA_HSTDT-COMMENT_31, sy-vline,
WA_OIUREP_EIA_HSTDT-COMMENT_42, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUREP_EIA_HSTDT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUREP_EIA_HSTDT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUREP_EIA_HSTDT INTO WA_OIUREP_EIA_HSTDT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUREP_EIA_HSTDT_STR,
MANDT TYPE STRING,
EIAHSTDT_UUID TYPE STRING,
REG_NUMBER TYPE STRING,
PRI_GEO_LOC TYPE STRING,
RPT_COLUMN TYPE STRING,
STD_VOL TYPE STRING,
BASE_DENSITY TYPE STRING,
VARIANCE TYPE STRING,
COMMENT_21 TYPE STRING,
COMMENT_31 TYPE STRING,
COMMENT_42 TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUREP_EIA_HSTDT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUREP_EIA_HSTDT_STR-MANDT sy-vline
WA_OIUREP_EIA_HSTDT_STR-EIAHSTDT_UUID sy-vline
WA_OIUREP_EIA_HSTDT_STR-REG_NUMBER sy-vline
WA_OIUREP_EIA_HSTDT_STR-PRI_GEO_LOC sy-vline
WA_OIUREP_EIA_HSTDT_STR-RPT_COLUMN sy-vline
WA_OIUREP_EIA_HSTDT_STR-STD_VOL sy-vline
WA_OIUREP_EIA_HSTDT_STR-BASE_DENSITY sy-vline
WA_OIUREP_EIA_HSTDT_STR-VARIANCE sy-vline
WA_OIUREP_EIA_HSTDT_STR-COMMENT_21 sy-vline
WA_OIUREP_EIA_HSTDT_STR-COMMENT_31 sy-vline
WA_OIUREP_EIA_HSTDT_STR-COMMENT_42 sy-vline
WA_OIUREP_EIA_HSTDT_STR-OIU_CRUSER sy-vline
WA_OIUREP_EIA_HSTDT_STR-OIU_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.