ABAP Select data from SAP table OPS_PSFCPICK_CMP_DATA_PDF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OPS_PSFCPICK_CMP_DATA_PDF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OPS_PSFCPICK_CMP_DATA_PDF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OPS_PSFCPICK_CMP_DATA_PDF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OPS_PSFCPICK_CMP_DATA_PDF TYPE STANDARD TABLE OF OPS_PSFCPICK_CMP_DATA_PDF, WA_OPS_PSFCPICK_CMP_DATA_PDF TYPE OPS_PSFCPICK_CMP_DATA_PDF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OPS_PSFCPICK_CMP_DATA_PDF> TYPE OPS_PSFCPICK_CMP_DATA_PDF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OPS_PSFCPICK_CMP_DATA_PDF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OPS_PSFCPICK_CMP_DATA_PDF INTO TABLE IT_OPS_PSFCPICK_CMP_DATA_PDF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OPS_PSFCPICK_CMP_DATA_PDF * INTO TABLE @DATA(IT_OPS_PSFCPICK_CMP_DATA_PDF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OPS_PSFCPICK_CMP_DATA_PDF INDEX 1 INTO DATA(WA_OPS_PSFCPICK_CMP_DATA_PDF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OPS_PSFCPICK_CMP_DATA_PDF ASSIGNING <OPS_PSFCPICK_CMP_DATA_PDF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OPS_PSFCPICK_CMP_DATA_PDF>-RSPOS = 1.
<OPS_PSFCPICK_CMP_DATA_PDF>-ALPOS = 1.
<OPS_PSFCPICK_CMP_DATA_PDF>-DUMPS = 1.
<OPS_PSFCPICK_CMP_DATA_PDF>-SCHGT = 1.
<OPS_PSFCPICK_CMP_DATA_PDF>-MATNR = 1.
ENDLOOP. LOOP AT IT_OPS_PSFCPICK_CMP_DATA_PDF INTO WA_OPS_PSFCPICK_CMP_DATA_PDF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OPS_PSFCPICK_CMP_DATA_PDF-WERKS, sy-vline,
WA_OPS_PSFCPICK_CMP_DATA_PDF-LGORT, sy-vline,
WA_OPS_PSFCPICK_CMP_DATA_PDF-CHARG, sy-vline,
WA_OPS_PSFCPICK_CMP_DATA_PDF-POSTP, sy-vline,
WA_OPS_PSFCPICK_CMP_DATA_PDF-BDMNG, sy-vline,
WA_OPS_PSFCPICK_CMP_DATA_PDF-MEINS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OPS_PSFCPICK_CMP_DATA_PDF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OPS_PSFCPICK_CMP_DATA_PDF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OPS_PSFCPICK_CMP_DATA_PDF INTO WA_OPS_PSFCPICK_CMP_DATA_PDF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OPS_PSFCPICK_CMP_DATA_PDF-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCPICK_CMP_DATA_PDF-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCPICK_CMP_DATA_PDF-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCPICK_CMP_DATA_PDF-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_OPS_PSFCPICK_CMP_DATA_PDF-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCPICK_CMP_DATA_PDF-VORNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field APLFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_PSFCPICK_CMP_DATA_PDF-APLFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCPICK_CMP_DATA_PDF-APLFL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OPS_PSFCPICK_CMP_DATA_PDF_STR,
RSPOS TYPE STRING,
ALPOS TYPE STRING,
DUMPS TYPE STRING,
SCHGT TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
POSTP TYPE STRING,
BDMNG TYPE STRING,
MEINS TYPE STRING,
POSNR TYPE STRING,
KZAUS TYPE STRING,
BEIKZ TYPE STRING,
MAKTX TYPE STRING,
TXTPS TYPE STRING,
BDTER TYPE STRING,
VORNR TYPE STRING,
APLFL TYPE STRING,
POTX1 TYPE STRING,
SGT_RCAT TYPE STRING,
SGT_SCAT TYPE STRING,
WRF_CHARSTC1 TYPE STRING,
WRF_CHARSTC2 TYPE STRING,
WRF_CHARSTC3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_OPS_PSFCPICK_CMP_DATA_PDF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-RSPOS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-ALPOS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-DUMPS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-SCHGT sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-MATNR sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-WERKS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-LGORT sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-CHARG sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-POSTP sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-BDMNG sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-MEINS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-POSNR sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-KZAUS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-BEIKZ sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-MAKTX sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-TXTPS sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-BDTER sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-VORNR sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-APLFL sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-POTX1 sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-SGT_RCAT sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-SGT_SCAT sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-WRF_CHARSTC1 sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-WRF_CHARSTC2 sy-vline
WA_OPS_PSFCPICK_CMP_DATA_PDF_STR-WRF_CHARSTC3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.