ABAP Select data from SAP table OPS_SE_IDCONFCRTRQ_IN_STY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OPS_SE_IDCONFCRTRQ_IN_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OPS_SE_IDCONFCRTRQ_IN_STY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OPS_SE_IDCONFCRTRQ_IN_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OPS_SE_IDCONFCRTRQ_IN_STY TYPE STANDARD TABLE OF OPS_SE_IDCONFCRTRQ_IN_STY, WA_OPS_SE_IDCONFCRTRQ_IN_STY TYPE OPS_SE_IDCONFCRTRQ_IN_STY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OPS_SE_IDCONFCRTRQ_IN_STY> TYPE OPS_SE_IDCONFCRTRQ_IN_STY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OPS_SE_IDCONFCRTRQ_IN_STY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OPS_SE_IDCONFCRTRQ_IN_STY INTO TABLE IT_OPS_SE_IDCONFCRTRQ_IN_STY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OPS_SE_IDCONFCRTRQ_IN_STY * INTO TABLE @DATA(IT_OPS_SE_IDCONFCRTRQ_IN_STY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OPS_SE_IDCONFCRTRQ_IN_STY INDEX 1 INTO DATA(WA_OPS_SE_IDCONFCRTRQ_IN_STY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OPS_SE_IDCONFCRTRQ_IN_STY ASSIGNING <OPS_SE_IDCONFCRTRQ_IN_STY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OPS_SE_IDCONFCRTRQ_IN_STY>-HANDLING_UNIT_HEADER = 1.
<OPS_SE_IDCONFCRTRQ_IN_STY>-HANDLING_UNIT_ITEM = 1.
<OPS_SE_IDCONFCRTRQ_IN_STY>-HANDLING_UNIT_SERNO = 1.
<OPS_SE_IDCONFCRTRQ_IN_STY>-HEADER_CONTROL = 1.
<OPS_SE_IDCONFCRTRQ_IN_STY>-DELIV_NUMB = 1.
ENDLOOP. LOOP AT IT_OPS_SE_IDCONFCRTRQ_IN_STY INTO WA_OPS_SE_IDCONFCRTRQ_IN_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OPS_SE_IDCONFCRTRQ_IN_STY-GROSS_WT_FLG, sy-vline,
WA_OPS_SE_IDCONFCRTRQ_IN_STY-NET_WT_FLG, sy-vline,
WA_OPS_SE_IDCONFCRTRQ_IN_STY-VOLUME_FLG, sy-vline,
WA_OPS_SE_IDCONFCRTRQ_IN_STY-POST_GI_FLG, sy-vline,
WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_DATE_FLG, sy-vline,
WA_OPS_SE_IDCONFCRTRQ_IN_STY-DOCK_FLG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OPS_SE_IDCONFCRTRQ_IN_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OPS_SE_IDCONFCRTRQ_IN_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OPS_SE_IDCONFCRTRQ_IN_STY INTO WA_OPS_SE_IDCONFCRTRQ_IN_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_OF_WT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-UNIT_OF_WT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-UNIT_OF_WT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECV_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_IDCONFCRTRQ_IN_STY-RECV_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_IDCONFCRTRQ_IN_STY-RECV_SYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OPS_SE_IDCONFCRTRQ_IN_STY_STR,
HANDLING_UNIT_HEADER TYPE STRING,
HANDLING_UNIT_ITEM TYPE STRING,
HANDLING_UNIT_SERNO TYPE STRING,
HEADER_CONTROL TYPE STRING,
DELIV_NUMB TYPE STRING,
GROSS_WT_FLG TYPE STRING,
NET_WT_FLG TYPE STRING,
VOLUME_FLG TYPE STRING,
POST_GI_FLG TYPE STRING,
DELIV_DATE_FLG TYPE STRING,
DOCK_FLG TYPE STRING,
DLV_DEL TYPE STRING,
SIMULATE TYPE STRING,
DLV_EXTID_FLG TYPE STRING,
NO_LOCK TYPE STRING,
HEADER_CONTROL_SPL TYPE STRING,
DELIV_NUMB TYPE STRING,
SENDER_METHOD TYPE STRING,
HEADER_DATA TYPE STRING,
DELIV_NUMB TYPE STRING,
GROSS_WT TYPE STRING,
NET_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_OF_WT_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUMEUNIT TYPE STRING,
VOLUMEUNIT_ISO TYPE STRING,
DOOR TYPE STRING,
EXTDELV_NO TYPE STRING,
HEADER_DATA_SPL TYPE STRING,
DELIV_NUMB TYPE STRING,
WHSE_REF_NMBR TYPE STRING,
WHSE_ORG_REF_NMBR TYPE STRING,
HU_UPDATE_REQUEST TYPE STRING,
PREV_DOC_NO TYPE STRING,
PREV_DOC_TYPE TYPE STRING,
GTS_STOCK_TYPE TYPE STRING,
UNLOADING_POINT TYPE STRING,
MODE_OF_TRANS TYPE STRING,
PROGRESSIVE_IDENT_NMBR TYPE STRING,
HEADER_DEADLINES TYPE STRING,
HEADER_PARTNER TYPE STRING,
HEADER_PARTNER_ADDR TYPE STRING,
TECHN_CONTROL TYPE STRING,
DEBUG_FLG TYPE STRING,
UPD_IND TYPE STRING,
RECV_WHS_NO TYPE STRING,
RECV_SYS TYPE STRING,
DLV_TYPE TYPE STRING,
INTERNAL_QUEUE TYPE STRING,
SERVICE_CALL TYPE STRING,
ITEM_CONTROL TYPE STRING,
ITEM_DATA TYPE STRING,
ITEM_DATA_SPL TYPE STRING,
ITEM_SERIAL_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HANDLING_UNIT_HEADER sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HANDLING_UNIT_ITEM sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HANDLING_UNIT_SERNO sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_CONTROL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-GROSS_WT_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-NET_WT_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-VOLUME_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-POST_GI_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DELIV_DATE_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DOCK_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DLV_DEL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-SIMULATE sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DLV_EXTID_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-NO_LOCK sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_CONTROL_SPL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-SENDER_METHOD sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_DATA sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-GROSS_WT sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-NET_WEIGHT sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-UNIT_OF_WT sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-UNIT_OF_WT_ISO sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-VOLUME sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-VOLUMEUNIT sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-VOLUMEUNIT_ISO sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DOOR sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-EXTDELV_NO sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_DATA_SPL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-WHSE_REF_NMBR sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-WHSE_ORG_REF_NMBR sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HU_UPDATE_REQUEST sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-PREV_DOC_NO sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-PREV_DOC_TYPE sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-GTS_STOCK_TYPE sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-UNLOADING_POINT sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-MODE_OF_TRANS sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-PROGRESSIVE_IDENT_NMBR sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_DEADLINES sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_PARTNER sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-HEADER_PARTNER_ADDR sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-TECHN_CONTROL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DEBUG_FLG sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-UPD_IND sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-RECV_WHS_NO sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-RECV_SYS sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-DLV_TYPE sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-INTERNAL_QUEUE sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-SERVICE_CALL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-ITEM_CONTROL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-ITEM_DATA sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-ITEM_DATA_SPL sy-vline
WA_OPS_SE_IDCONFCRTRQ_IN_STY_STR-ITEM_SERIAL_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.