ABAP Select data from SAP table P01C_VDATH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P01C_VDATH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P01C_VDATH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P01C_VDATH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P01C_VDATH TYPE STANDARD TABLE OF P01C_VDATH,
      WA_P01C_VDATH TYPE P01C_VDATH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P01C_VDATH> TYPE P01C_VDATH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P01C_VDATH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P01C_VDATH
  INTO TABLE IT_P01C_VDATH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P01C_VDATH
*  INTO TABLE @DATA(IT_P01C_VDATH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P01C_VDATH INDEX 1 INTO DATA(WA_P01C_VDATH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P01C_VDATH ASSIGNING <P01C_VDATH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P01C_VDATH>-NACHN = 1.
<P01C_VDATH>-VORNA = 1.
<P01C_VDATH>-ASBEG = 1.
<P01C_VDATH>-MASSN = 1.
<P01C_VDATH>-MASSG = 1.
ENDLOOP.

LOOP AT IT_P01C_VDATH INTO WA_P01C_VDATH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P01C_VDATH-STAT1, sy-vline,
WA_P01C_VDATH-STAT2, sy-vline,
WA_P01C_VDATH-LSBEG, sy-vline,
WA_P01C_VDATH-LMSSN, sy-vline,
WA_P01C_VDATH-LMSSG, sy-vline,
WA_P01C_VDATH-LSTA1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P01C_VDATH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P01C_VDATH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P01C_VDATH INTO WA_P01C_VDATH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_P01C_VDATH-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P01C_VDATH-GBDAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P01C_VDATH_STR,
NACHN TYPE STRING,
VORNA TYPE STRING,
ASBEG TYPE STRING,
MASSN TYPE STRING,
MASSG TYPE STRING,
STAT1 TYPE STRING,
STAT2 TYPE STRING,
LSBEG TYPE STRING,
LMSSN TYPE STRING,
LMSSG TYPE STRING,
LSTA1 TYPE STRING,
LSTA2 TYPE STRING,
RNTOP TYPE STRING,
REART TYPE STRING,
GBDAT TYPE STRING,
GESCH TYPE STRING,
FAMST TYPE STRING,
FAMDT TYPE STRING,
JUPER TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ERBNR TYPE STRING,
SBGRU TYPE STRING,
SBPRO TYPE STRING,END OF T_EKKO_STR. DATA: WA_P01C_VDATH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P01C_VDATH_STR-NACHN sy-vline
WA_P01C_VDATH_STR-VORNA sy-vline
WA_P01C_VDATH_STR-ASBEG sy-vline
WA_P01C_VDATH_STR-MASSN sy-vline
WA_P01C_VDATH_STR-MASSG sy-vline
WA_P01C_VDATH_STR-STAT1 sy-vline
WA_P01C_VDATH_STR-STAT2 sy-vline
WA_P01C_VDATH_STR-LSBEG sy-vline
WA_P01C_VDATH_STR-LMSSN sy-vline
WA_P01C_VDATH_STR-LMSSG sy-vline
WA_P01C_VDATH_STR-LSTA1 sy-vline
WA_P01C_VDATH_STR-LSTA2 sy-vline
WA_P01C_VDATH_STR-RNTOP sy-vline
WA_P01C_VDATH_STR-REART sy-vline
WA_P01C_VDATH_STR-GBDAT sy-vline
WA_P01C_VDATH_STR-GESCH sy-vline
WA_P01C_VDATH_STR-FAMST sy-vline
WA_P01C_VDATH_STR-FAMDT sy-vline
WA_P01C_VDATH_STR-JUPER sy-vline
WA_P01C_VDATH_STR-BUKRS sy-vline
WA_P01C_VDATH_STR-WERKS sy-vline
WA_P01C_VDATH_STR-BTRTL sy-vline
WA_P01C_VDATH_STR-PERSG sy-vline
WA_P01C_VDATH_STR-PERSK sy-vline
WA_P01C_VDATH_STR-ERBNR sy-vline
WA_P01C_VDATH_STR-SBGRU sy-vline
WA_P01C_VDATH_STR-SBPRO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.