ABAP Select data from SAP table P01P_RPSPSTD0_PSST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P01P_RPSPSTD0_PSST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P01P_RPSPSTD0_PSST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P01P_RPSPSTD0_PSST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P01P_RPSPSTD0_PSST TYPE STANDARD TABLE OF P01P_RPSPSTD0_PSST, WA_P01P_RPSPSTD0_PSST TYPE P01P_RPSPSTD0_PSST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <P01P_RPSPSTD0_PSST> TYPE P01P_RPSPSTD0_PSST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_P01P_RPSPSTD0_PSST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM P01P_RPSPSTD0_PSST INTO TABLE IT_P01P_RPSPSTD0_PSST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM P01P_RPSPSTD0_PSST * INTO TABLE @DATA(IT_P01P_RPSPSTD0_PSST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_P01P_RPSPSTD0_PSST INDEX 1 INTO DATA(WA_P01P_RPSPSTD0_PSST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_P01P_RPSPSTD0_PSST ASSIGNING <P01P_RPSPSTD0_PSST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<P01P_RPSPSTD0_PSST>-LAND = 1.
<P01P_RPSPSTD0_PSST>-BESCHBER = 1.
<P01P_RPSPSTD0_PSST>-BERSTNR = 1.
<P01P_RPSPSTD0_PSST>-LFDNR = 1.
<P01P_RPSPSTD0_PSST>-STAUFGB = 1.
ENDLOOP. LOOP AT IT_P01P_RPSPSTD0_PSST INTO WA_P01P_RPSPSTD0_PSST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P01P_RPSPSTD0_PSST-KAUFGB, sy-vline,
WA_P01P_RPSPSTD0_PSST-GESCH, sy-vline,
WA_P01P_RPSPSTD0_PSST-GEBMON, sy-vline,
WA_P01P_RPSPSTD0_PSST-GEBJAHR, sy-vline,
WA_P01P_RPSPSTD0_PSST-BESCHUMF, sy-vline,
WA_P01P_RPSPSTD0_PSST-DIENSTD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P01P_RPSPSTD0_PSST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P01P_RPSPSTD0_PSST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P01P_RPSPSTD0_PSST INTO WA_P01P_RPSPSTD0_PSST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P01P_RPSPSTD0_PSST_STR,
LAND TYPE STRING,
BESCHBER TYPE STRING,
BERSTNR TYPE STRING,
LFDNR TYPE STRING,
STAUFGB TYPE STRING,
KAUFGB TYPE STRING,
GESCH TYPE STRING,
GEBMON TYPE STRING,
GEBJAHR TYPE STRING,
BESCHUMF TYPE STRING,
DIENSTD TYPE STRING,
DIENSTA TYPE STRING,
LBGRUPPE TYPE STRING,
EINSTUF TYPE STRING,
DIOLAND TYPE STRING,
DIORBEZ TYPE STRING,
DIOKREIS TYPE STRING,
DIOGEM TYPE STRING,
GEMGRKL TYPE STRING,
KAPLHAUS TYPE STRING,
DLASTUFE TYPE STRING,
FAMSTOZ TYPE STRING,
KIANTOZ TYPE STRING,
WOHNLAND TYPE STRING,
WOHNRBEZ TYPE STRING,
WOHNKREIS TYPE STRING,
WOHNGEM TYPE STRING,
ARBFAKT TYPE STRING,
ARBFAKTU2 TYPE STRING,
PLZ TYPE STRING,
LEER TYPE STRING,
GKZNAME TYPE STRING,
LIEFERANT TYPE STRING,
STEUBRU TYPE STRING,
OWKZN TYPE STRING,
V_LSTNG TYPE STRING,
ZULAGE TYPE STRING,
ART1 TYPE STRING,
ZULAGE1 TYPE STRING,
ART2 TYPE STRING,
ZULAGE2 TYPE STRING,
ART3 TYPE STRING,
ZULAGE3 TYPE STRING,
ART4 TYPE STRING,
ZULAGE4 TYPE STRING,
ART5 TYPE STRING,
ZULAGE5 TYPE STRING,
ART6 TYPE STRING,
ZULAGE6 TYPE STRING,
ART7 TYPE STRING,
ZULAGE7 TYPE STRING,
ART8 TYPE STRING,
ZULAGE8 TYPE STRING,
EF41 TYPE STRING,
KPRODNR TYPE STRING,
TVART TYPE STRING,
BESTD TYPE STRING,
STAUSGL TYPE STRING,
MOSOZ TYPE STRING,
TRWAZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_P01P_RPSPSTD0_PSST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P01P_RPSPSTD0_PSST_STR-LAND sy-vline
WA_P01P_RPSPSTD0_PSST_STR-BESCHBER sy-vline
WA_P01P_RPSPSTD0_PSST_STR-BERSTNR sy-vline
WA_P01P_RPSPSTD0_PSST_STR-LFDNR sy-vline
WA_P01P_RPSPSTD0_PSST_STR-STAUFGB sy-vline
WA_P01P_RPSPSTD0_PSST_STR-KAUFGB sy-vline
WA_P01P_RPSPSTD0_PSST_STR-GESCH sy-vline
WA_P01P_RPSPSTD0_PSST_STR-GEBMON sy-vline
WA_P01P_RPSPSTD0_PSST_STR-GEBJAHR sy-vline
WA_P01P_RPSPSTD0_PSST_STR-BESCHUMF sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DIENSTD sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DIENSTA sy-vline
WA_P01P_RPSPSTD0_PSST_STR-LBGRUPPE sy-vline
WA_P01P_RPSPSTD0_PSST_STR-EINSTUF sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DIOLAND sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DIORBEZ sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DIOKREIS sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DIOGEM sy-vline
WA_P01P_RPSPSTD0_PSST_STR-GEMGRKL sy-vline
WA_P01P_RPSPSTD0_PSST_STR-KAPLHAUS sy-vline
WA_P01P_RPSPSTD0_PSST_STR-DLASTUFE sy-vline
WA_P01P_RPSPSTD0_PSST_STR-FAMSTOZ sy-vline
WA_P01P_RPSPSTD0_PSST_STR-KIANTOZ sy-vline
WA_P01P_RPSPSTD0_PSST_STR-WOHNLAND sy-vline
WA_P01P_RPSPSTD0_PSST_STR-WOHNRBEZ sy-vline
WA_P01P_RPSPSTD0_PSST_STR-WOHNKREIS sy-vline
WA_P01P_RPSPSTD0_PSST_STR-WOHNGEM sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ARBFAKT sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ARBFAKTU2 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-PLZ sy-vline
WA_P01P_RPSPSTD0_PSST_STR-LEER sy-vline
WA_P01P_RPSPSTD0_PSST_STR-GKZNAME sy-vline
WA_P01P_RPSPSTD0_PSST_STR-LIEFERANT sy-vline
WA_P01P_RPSPSTD0_PSST_STR-STEUBRU sy-vline
WA_P01P_RPSPSTD0_PSST_STR-OWKZN sy-vline
WA_P01P_RPSPSTD0_PSST_STR-V_LSTNG sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART1 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE1 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART2 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE2 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART3 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE3 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART4 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE4 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART5 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE5 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART6 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE6 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART7 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE7 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ART8 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-ZULAGE8 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-EF41 sy-vline
WA_P01P_RPSPSTD0_PSST_STR-KPRODNR sy-vline
WA_P01P_RPSPSTD0_PSST_STR-TVART sy-vline
WA_P01P_RPSPSTD0_PSST_STR-BESTD sy-vline
WA_P01P_RPSPSTD0_PSST_STR-STAUSGL sy-vline
WA_P01P_RPSPSTD0_PSST_STR-MOSOZ sy-vline
WA_P01P_RPSPSTD0_PSST_STR-TRWAZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.