ABAP Select data from SAP table P02VS_TAB_PRINTREC2 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P02VS_TAB_PRINTREC2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P02VS_TAB_PRINTREC2. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P02VS_TAB_PRINTREC2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P02VS_TAB_PRINTREC2 TYPE STANDARD TABLE OF P02VS_TAB_PRINTREC2, WA_P02VS_TAB_PRINTREC2 TYPE P02VS_TAB_PRINTREC2, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <P02VS_TAB_PRINTREC2> TYPE P02VS_TAB_PRINTREC2. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_P02VS_TAB_PRINTREC2. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM P02VS_TAB_PRINTREC2 INTO TABLE IT_P02VS_TAB_PRINTREC2. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM P02VS_TAB_PRINTREC2 * INTO TABLE @DATA(IT_P02VS_TAB_PRINTREC22). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_P02VS_TAB_PRINTREC2 INDEX 1 INTO DATA(WA_P02VS_TAB_PRINTREC22). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_P02VS_TAB_PRINTREC2 ASSIGNING <P02VS_TAB_PRINTREC2>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<P02VS_TAB_PRINTREC2>-PERNR = 1.
<P02VS_TAB_PRINTREC2>-AHVNR = 1.
<P02VS_TAB_PRINTREC2>-GBDAT = 1.
<P02VS_TAB_PRINTREC2>-EINDT = 1.
<P02VS_TAB_PRINTREC2>-NAME1 = 1.
ENDLOOP. LOOP AT IT_P02VS_TAB_PRINTREC2 INTO WA_P02VS_TAB_PRINTREC2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P02VS_TAB_PRINTREC2-ENAME, sy-vline,
WA_P02VS_TAB_PRINTREC2-NAME_PERS, sy-vline,
WA_P02VS_TAB_PRINTREC2-NAME_CO, sy-vline,
WA_P02VS_TAB_PRINTREC2-GESCH, sy-vline,
WA_P02VS_TAB_PRINTREC2-ANRED, sy-vline,
WA_P02VS_TAB_PRINTREC2-SPRAS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P02VS_TAB_PRINTREC2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P02VS_TAB_PRINTREC2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P02VS_TAB_PRINTREC2 INTO WA_P02VS_TAB_PRINTREC2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit AHVNR, internal->external for field AHVNR CALL FUNCTION 'CONVERSION_EXIT_AHVNR_OUTPUT' EXPORTING input = WA_P02VS_TAB_PRINTREC2-AHVNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P02VS_TAB_PRINTREC2-AHVNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_P02VS_TAB_PRINTREC2-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P02VS_TAB_PRINTREC2-SPRAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit AHVN2, internal->external for field NAHVN CALL FUNCTION 'CONVERSION_EXIT_AHVN2_OUTPUT' EXPORTING input = WA_P02VS_TAB_PRINTREC2-NAHVN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P02VS_TAB_PRINTREC2-NAHVN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P02VS_TAB_PRINTREC2_STR,
PERNR TYPE STRING,
AHVNR TYPE STRING,
GBDAT TYPE STRING,
EINDT TYPE STRING,
NAME1 TYPE STRING,
ENAME TYPE STRING,
NAME_PERS TYPE STRING,
NAME_CO TYPE STRING,
GESCH TYPE STRING,
ANRED TYPE STRING,
SPRAS TYPE STRING,
STRAS TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
REGIO TYPE STRING,
LAND1 TYPE STRING,
NAHVN TYPE STRING,
VAL01 TYPE STRING,
VAL02 TYPE STRING,
VAL03 TYPE STRING,
VAL04 TYPE STRING,
VAL05 TYPE STRING,
VAL06 TYPE STRING,
VAL07 TYPE STRING,
VAL08 TYPE STRING,
VAL09 TYPE STRING,
VAL10 TYPE STRING,
VAL11 TYPE STRING,
VAL12 TYPE STRING,
VAL13 TYPE STRING,
VAL14 TYPE STRING,
VAL15 TYPE STRING,
VAL16 TYPE STRING,
VAL17 TYPE STRING,
VAL18 TYPE STRING,
VAL19 TYPE STRING,
VAL20 TYPE STRING,
VAL21 TYPE STRING,
VAL22 TYPE STRING,
VAL23 TYPE STRING,
VAL24 TYPE STRING,
VAL25 TYPE STRING,
VAL26 TYPE STRING,
VAL27 TYPE STRING,
VAL28 TYPE STRING,
VAL29 TYPE STRING,
VAL30 TYPE STRING,
VAL31 TYPE STRING,
VAL32 TYPE STRING,
VAL33 TYPE STRING,
VAL34 TYPE STRING,
VAL35 TYPE STRING,
VAL36 TYPE STRING,
VAL37 TYPE STRING,
VAL38 TYPE STRING,
VAL39 TYPE STRING,
VAL40 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P02VS_TAB_PRINTREC2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P02VS_TAB_PRINTREC2_STR-PERNR sy-vline
WA_P02VS_TAB_PRINTREC2_STR-AHVNR sy-vline
WA_P02VS_TAB_PRINTREC2_STR-GBDAT sy-vline
WA_P02VS_TAB_PRINTREC2_STR-EINDT sy-vline
WA_P02VS_TAB_PRINTREC2_STR-NAME1 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-ENAME sy-vline
WA_P02VS_TAB_PRINTREC2_STR-NAME_PERS sy-vline
WA_P02VS_TAB_PRINTREC2_STR-NAME_CO sy-vline
WA_P02VS_TAB_PRINTREC2_STR-GESCH sy-vline
WA_P02VS_TAB_PRINTREC2_STR-ANRED sy-vline
WA_P02VS_TAB_PRINTREC2_STR-SPRAS sy-vline
WA_P02VS_TAB_PRINTREC2_STR-STRAS sy-vline
WA_P02VS_TAB_PRINTREC2_STR-PSTLZ sy-vline
WA_P02VS_TAB_PRINTREC2_STR-ORT01 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-REGIO sy-vline
WA_P02VS_TAB_PRINTREC2_STR-LAND1 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-NAHVN sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL01 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL02 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL03 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL04 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL05 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL06 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL07 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL08 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL09 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL10 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL11 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL12 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL13 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL14 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL15 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL16 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL17 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL18 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL19 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL20 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL21 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL22 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL23 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL24 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL25 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL26 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL27 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL28 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL29 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL30 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL31 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL32 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL33 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL34 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL35 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL36 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL37 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL38 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL39 sy-vline
WA_P02VS_TAB_PRINTREC2_STR-VAL40 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.