ABAP Select data from SAP table P0671 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P0671 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P0671. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P0671 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P0671 TYPE STANDARD TABLE OF P0671, WA_P0671 TYPE P0671, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <P0671> TYPE P0671. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_P0671. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM P0671 INTO TABLE IT_P0671. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM P0671 * INTO TABLE @DATA(IT_P06712). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_P0671 INDEX 1 INTO DATA(WA_P06712). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_P0671 ASSIGNING <P0671>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<P0671>-PERNR = 1.
<P0671>-INFTY = 1.
<P0671>-SUBTY = 1.
<P0671>-OBJPS = 1.
<P0671>-SPRPS = 1.
ENDLOOP. LOOP AT IT_P0671 INTO WA_P0671. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P0671-ENDDA, sy-vline,
WA_P0671-BEGDA, sy-vline,
WA_P0671-SEQNR, sy-vline,
WA_P0671-AEDTM, sy-vline,
WA_P0671-UNAME, sy-vline,
WA_P0671-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P0671 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P0671 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P0671 INTO WA_P0671. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P0671_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
BAREA TYPE STRING,
PLTYP TYPE STRING,
BPLAN TYPE STRING,
DSUBT TYPE STRING,
DOBJP TYPE STRING,END OF T_EKKO_STR. DATA: WA_P0671_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P0671_STR-PERNR sy-vline
WA_P0671_STR-INFTY sy-vline
WA_P0671_STR-SUBTY sy-vline
WA_P0671_STR-OBJPS sy-vline
WA_P0671_STR-SPRPS sy-vline
WA_P0671_STR-ENDDA sy-vline
WA_P0671_STR-BEGDA sy-vline
WA_P0671_STR-SEQNR sy-vline
WA_P0671_STR-AEDTM sy-vline
WA_P0671_STR-UNAME sy-vline
WA_P0671_STR-HISTO sy-vline
WA_P0671_STR-ITXEX sy-vline
WA_P0671_STR-REFEX sy-vline
WA_P0671_STR-ORDEX sy-vline
WA_P0671_STR-ITBLD sy-vline
WA_P0671_STR-PREAS sy-vline
WA_P0671_STR-FLAG1 sy-vline
WA_P0671_STR-FLAG2 sy-vline
WA_P0671_STR-FLAG3 sy-vline
WA_P0671_STR-FLAG4 sy-vline
WA_P0671_STR-RESE1 sy-vline
WA_P0671_STR-RESE2 sy-vline
WA_P0671_STR-GRPVL sy-vline
WA_P0671_STR-BAREA sy-vline
WA_P0671_STR-PLTYP sy-vline
WA_P0671_STR-BPLAN sy-vline
WA_P0671_STR-DSUBT sy-vline
WA_P0671_STR-DOBJP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.