ABAP Select data from SAP table P06CR_BRC_HISTORY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06CR_BRC_HISTORY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06CR_BRC_HISTORY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P06CR_BRC_HISTORY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P06CR_BRC_HISTORY TYPE STANDARD TABLE OF P06CR_BRC_HISTORY, WA_P06CR_BRC_HISTORY TYPE P06CR_BRC_HISTORY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <P06CR_BRC_HISTORY> TYPE P06CR_BRC_HISTORY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_P06CR_BRC_HISTORY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM P06CR_BRC_HISTORY INTO TABLE IT_P06CR_BRC_HISTORY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM P06CR_BRC_HISTORY * INTO TABLE @DATA(IT_P06CR_BRC_HISTORY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_P06CR_BRC_HISTORY INDEX 1 INTO DATA(WA_P06CR_BRC_HISTORY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_P06CR_BRC_HISTORY ASSIGNING <P06CR_BRC_HISTORY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<P06CR_BRC_HISTORY>-MANDT = 1.
<P06CR_BRC_HISTORY>-BUKRS = 1.
<P06CR_BRC_HISTORY>-SIREN = 1.
<P06CR_BRC_HISTORY>-NUMIC = 1.
<P06CR_BRC_HISTORY>-INPER = 1.
ENDLOOP. LOOP AT IT_P06CR_BRC_HISTORY INTO WA_P06CR_BRC_HISTORY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P06CR_BRC_HISTORY-IN_BEGDA, sy-vline,
WA_P06CR_BRC_HISTORY-IN_ENDDA, sy-vline,
WA_P06CR_BRC_HISTORY-FPPER, sy-vline,
WA_P06CR_BRC_HISTORY-FP_BEGDA, sy-vline,
WA_P06CR_BRC_HISTORY-FP_ENDDA, sy-vline,
WA_P06CR_BRC_HISTORY-CATEG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P06CR_BRC_HISTORY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06CR_BRC_HISTORY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06CR_BRC_HISTORY INTO WA_P06CR_BRC_HISTORY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06CR_BRC_HISTORY_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
SIREN TYPE STRING,
NUMIC TYPE STRING,
INPER TYPE STRING,
IN_BEGDA TYPE STRING,
IN_ENDDA TYPE STRING,
FPPER TYPE STRING,
FP_BEGDA TYPE STRING,
FP_ENDDA TYPE STRING,
CATEG TYPE STRING,
SCREEN_CATEG TYPE STRING,
CORGA TYPE STRING,
PERTY TYPE STRING,
NATDEC TYPE STRING,
AT_RATE TYPE STRING,
PAID_HEADC TYPE STRING,
EXEMPT_HEADC TYPE STRING,
ENDOP_MEN TYPE STRING,
ENDOP_WOMEN TYPE STRING,
WAERS TYPE STRING,
CONT_BASIS TYPE STRING,
PAID_SALARY TYPE STRING,
NORMAL_RATE TYPE STRING,
NORMAL_CONT TYPE STRING,
SPECIAL_RATE TYPE STRING,
SPECIAL_CONT TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
ABKRS TYPE STRING,
PERMO TYPE STRING,
DATMO TYPE STRING,
CTMOD TYPE STRING,
RTMOD TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06CR_BRC_HISTORY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06CR_BRC_HISTORY_STR-MANDT sy-vline
WA_P06CR_BRC_HISTORY_STR-BUKRS sy-vline
WA_P06CR_BRC_HISTORY_STR-SIREN sy-vline
WA_P06CR_BRC_HISTORY_STR-NUMIC sy-vline
WA_P06CR_BRC_HISTORY_STR-INPER sy-vline
WA_P06CR_BRC_HISTORY_STR-IN_BEGDA sy-vline
WA_P06CR_BRC_HISTORY_STR-IN_ENDDA sy-vline
WA_P06CR_BRC_HISTORY_STR-FPPER sy-vline
WA_P06CR_BRC_HISTORY_STR-FP_BEGDA sy-vline
WA_P06CR_BRC_HISTORY_STR-FP_ENDDA sy-vline
WA_P06CR_BRC_HISTORY_STR-CATEG sy-vline
WA_P06CR_BRC_HISTORY_STR-SCREEN_CATEG sy-vline
WA_P06CR_BRC_HISTORY_STR-CORGA sy-vline
WA_P06CR_BRC_HISTORY_STR-PERTY sy-vline
WA_P06CR_BRC_HISTORY_STR-NATDEC sy-vline
WA_P06CR_BRC_HISTORY_STR-AT_RATE sy-vline
WA_P06CR_BRC_HISTORY_STR-PAID_HEADC sy-vline
WA_P06CR_BRC_HISTORY_STR-EXEMPT_HEADC sy-vline
WA_P06CR_BRC_HISTORY_STR-ENDOP_MEN sy-vline
WA_P06CR_BRC_HISTORY_STR-ENDOP_WOMEN sy-vline
WA_P06CR_BRC_HISTORY_STR-WAERS sy-vline
WA_P06CR_BRC_HISTORY_STR-CONT_BASIS sy-vline
WA_P06CR_BRC_HISTORY_STR-PAID_SALARY sy-vline
WA_P06CR_BRC_HISTORY_STR-NORMAL_RATE sy-vline
WA_P06CR_BRC_HISTORY_STR-NORMAL_CONT sy-vline
WA_P06CR_BRC_HISTORY_STR-SPECIAL_RATE sy-vline
WA_P06CR_BRC_HISTORY_STR-SPECIAL_CONT sy-vline
WA_P06CR_BRC_HISTORY_STR-WERKS sy-vline
WA_P06CR_BRC_HISTORY_STR-BTRTL sy-vline
WA_P06CR_BRC_HISTORY_STR-ABKRS sy-vline
WA_P06CR_BRC_HISTORY_STR-PERMO sy-vline
WA_P06CR_BRC_HISTORY_STR-DATMO sy-vline
WA_P06CR_BRC_HISTORY_STR-CTMOD sy-vline
WA_P06CR_BRC_HISTORY_STR-RTMOD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.