ABAP Select data from SAP table P12_DYNP735 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P12_DYNP735 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P12_DYNP735. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P12_DYNP735 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P12_DYNP735 TYPE STANDARD TABLE OF P12_DYNP735,
      WA_P12_DYNP735 TYPE P12_DYNP735,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P12_DYNP735> TYPE P12_DYNP735.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P12_DYNP735.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P12_DYNP735
  INTO TABLE IT_P12_DYNP735.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P12_DYNP735
*  INTO TABLE @DATA(IT_P12_DYNP7352).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P12_DYNP735 INDEX 1 INTO DATA(WA_P12_DYNP7352).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P12_DYNP735 ASSIGNING <P12_DYNP735>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P12_DYNP735>-DIDTP = 1.
<P12_DYNP735>-RSZNR = 1.
<P12_DYNP735>-ENDAT = 1.
<P12_DYNP735>-LVDAT = 1.
<P12_DYNP735>-DIMNR = 1.
ENDLOOP.

LOOP AT IT_P12_DYNP735 INTO WA_P12_DYNP735.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P12_DYNP735-DIRCN, sy-vline,
WA_P12_DYNP735-BEGPC, sy-vline,
WA_P12_DYNP735-WPADD, sy-vline,
WA_P12_DYNP735-NAAM1, sy-vline,
WA_P12_DYNP735-ADRES, sy-vline,
WA_P12_DYNP735-HSNMR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P12_DYNP735 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P12_DYNP735 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P12_DYNP735 INTO WA_P12_DYNP735. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P12_DYNP735_STR,
DIDTP TYPE STRING,
RSZNR TYPE STRING,
ENDAT TYPE STRING,
LVDAT TYPE STRING,
DIMNR TYPE STRING,
DIRCN TYPE STRING,
BEGPC TYPE STRING,
WPADD TYPE STRING,
NAAM1 TYPE STRING,
ADRES TYPE STRING,
HSNMR TYPE STRING,
POSTK TYPE STRING,
GEMEE TYPE STRING,
RSZBL TYPE STRING,
DIPBX TYPE STRING,
EE_QUAL TYPE STRING,
DISIS TYPE STRING,
RSZRR TYPE STRING,
DIC3C TYPE STRING,
DIC3F TYPE STRING,
DINNP TYPE STRING,
DIMN2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P12_DYNP735_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P12_DYNP735_STR-DIDTP sy-vline
WA_P12_DYNP735_STR-RSZNR sy-vline
WA_P12_DYNP735_STR-ENDAT sy-vline
WA_P12_DYNP735_STR-LVDAT sy-vline
WA_P12_DYNP735_STR-DIMNR sy-vline
WA_P12_DYNP735_STR-DIRCN sy-vline
WA_P12_DYNP735_STR-BEGPC sy-vline
WA_P12_DYNP735_STR-WPADD sy-vline
WA_P12_DYNP735_STR-NAAM1 sy-vline
WA_P12_DYNP735_STR-ADRES sy-vline
WA_P12_DYNP735_STR-HSNMR sy-vline
WA_P12_DYNP735_STR-POSTK sy-vline
WA_P12_DYNP735_STR-GEMEE sy-vline
WA_P12_DYNP735_STR-RSZBL sy-vline
WA_P12_DYNP735_STR-DIPBX sy-vline
WA_P12_DYNP735_STR-EE_QUAL sy-vline
WA_P12_DYNP735_STR-DISIS sy-vline
WA_P12_DYNP735_STR-RSZRR sy-vline
WA_P12_DYNP735_STR-DIC3C sy-vline
WA_P12_DYNP735_STR-DIC3F sy-vline
WA_P12_DYNP735_STR-DINNP sy-vline
WA_P12_DYNP735_STR-DIMN2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.