ABAP Select data from SAP table P15_730_UI_ALV_OUT_2012 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P15_730_UI_ALV_OUT_2012 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P15_730_UI_ALV_OUT_2012. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P15_730_UI_ALV_OUT_2012 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P15_730_UI_ALV_OUT_2012 TYPE STANDARD TABLE OF P15_730_UI_ALV_OUT_2012,
      WA_P15_730_UI_ALV_OUT_2012 TYPE P15_730_UI_ALV_OUT_2012,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P15_730_UI_ALV_OUT_2012> TYPE P15_730_UI_ALV_OUT_2012.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P15_730_UI_ALV_OUT_2012.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P15_730_UI_ALV_OUT_2012
  INTO TABLE IT_P15_730_UI_ALV_OUT_2012.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P15_730_UI_ALV_OUT_2012
*  INTO TABLE @DATA(IT_P15_730_UI_ALV_OUT_20122).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P15_730_UI_ALV_OUT_2012 INDEX 1 INTO DATA(WA_P15_730_UI_ALV_OUT_20122).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P15_730_UI_ALV_OUT_2012 ASSIGNING <P15_730_UI_ALV_OUT_2012>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P15_730_UI_ALV_OUT_2012>-PERNR = 1.
<P15_730_UI_ALV_OUT_2012>-PERID = 1.
<P15_730_UI_ALV_OUT_2012>-VORNA = 1.
<P15_730_UI_ALV_OUT_2012>-FIRE_DATE = 1.
<P15_730_UI_ALV_OUT_2012>-CFSOC = 1.
ENDLOOP.

LOOP AT IT_P15_730_UI_ALV_OUT_2012 INTO WA_P15_730_UI_ALV_OUT_2012.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P15_730_UI_ALV_OUT_2012-NOSOC, sy-vline,
WA_P15_730_UI_ALV_OUT_2012-COFIS, sy-vline,
WA_P15_730_UI_ALV_OUT_2012-NRATE, sy-vline,
WA_P15_730_UI_ALV_OUT_2012-IMRIRD, sy-vline,
WA_P15_730_UI_ALV_OUT_2012-IMRIRC, sy-vline,
WA_P15_730_UI_ALV_OUT_2012-IMTIRD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P15_730_UI_ALV_OUT_2012 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P15_730_UI_ALV_OUT_2012 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P15_730_UI_ALV_OUT_2012 INTO WA_P15_730_UI_ALV_OUT_2012. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P15_730_UI_ALV_OUT_2012_STR,
PERNR TYPE STRING,
PERID TYPE STRING,
VORNA TYPE STRING,
FIRE_DATE TYPE STRING,
CFSOC TYPE STRING,
NOSOC TYPE STRING,
COFIS TYPE STRING,
NRATE TYPE STRING,
IMRIRD TYPE STRING,
IMRIRC TYPE STRING,
IMTIRD TYPE STRING,
IMTIRC TYPE STRING,
RAAC1D TYPE STRING,
RAAC1C TYPE STRING,
RAAC2D TYPE STRING,
RAAC2C TYPE STRING,
IMRRD TYPE STRING,
CRED2 TYPE STRING,
IMRRC TYPE STRING,
CREC2 TYPE STRING,
IMTRD TYPE STRING,
CRED1 TYPE STRING,
IMTRC TYPE STRING,
CREC1 TYPE STRING,
IMRCD TYPE STRING,
CELD2 TYPE STRING,
IMRCC TYPE STRING,
CELC2 TYPE STRING,
IMTCD TYPE STRING,
CELD1 TYPE STRING,
IMTCC TYPE STRING,
CELC1 TYPE STRING,
AACOMD TYPE STRING,
CAACD TYPE STRING,
AACOMC TYPE STRING,
CAACC TYPE STRING,
ISLSD TYPE STRING,
ISLSC TYPE STRING,
RSLSD TYPE STRING,
RSLSC TYPE STRING,
ACTSD TYPE STRING,
ACTSC TYPE STRING,
RACTD TYPE STRING,
RACTC TYPE STRING,
CORIT TYPE STRING,
TIPOC TYPE STRING,
TIPOR TYPE STRING,
INTEG TYPE STRING,
DATAC TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
CONGLR TYPE STRING,
CONGLT TYPE STRING,
CETSLD TYPE STRING,
CETSLC TYPE STRING,
CERSLD TYPE STRING,
CERSLC TYPE STRING,
RASL1D TYPE STRING,
RASL1C TYPE STRING,
RASL2D TYPE STRING,
RASL2C TYPE STRING,
CONTSTD TYPE STRING,
CONTSTC TYPE STRING,
RCSOD TYPE STRING,
RCSOC TYPE STRING,
ANNULL TYPE STRING,END OF T_EKKO_STR. DATA: WA_P15_730_UI_ALV_OUT_2012_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-PERNR sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-PERID sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-VORNA sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-FIRE_DATE sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CFSOC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-NOSOC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-COFIS sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-NRATE sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMRIRD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMRIRC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMTIRD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMTIRC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RAAC1D sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RAAC1C sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RAAC2D sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RAAC2C sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMRRD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CRED2 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMRRC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CREC2 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMTRD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CRED1 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMTRC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CREC1 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMRCD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CELD2 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMRCC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CELC2 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMTCD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CELD1 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-IMTCC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CELC1 sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-AACOMD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CAACD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-AACOMC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CAACC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-ISLSD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-ISLSC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RSLSD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RSLSC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-ACTSD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-ACTSC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RACTD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RACTC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CORIT sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-TIPOC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-TIPOR sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-INTEG sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-DATAC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-BEGDA sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-ENDDA sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CONGLR sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CONGLT sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CETSLD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CETSLC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CERSLD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CERSLC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RASL1D sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RASL1C sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RASL2D sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RASL2C sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CONTSTD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-CONTSTC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RCSOD sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-RCSOC sy-vline
WA_P15_730_UI_ALV_OUT_2012_STR-ANNULL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.