ABAP Select data from SAP table P15_CBI_F24_EP_RECORD_A into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P15_CBI_F24_EP_RECORD_A table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P15_CBI_F24_EP_RECORD_A. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P15_CBI_F24_EP_RECORD_A table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P15_CBI_F24_EP_RECORD_A TYPE STANDARD TABLE OF P15_CBI_F24_EP_RECORD_A, WA_P15_CBI_F24_EP_RECORD_A TYPE P15_CBI_F24_EP_RECORD_A, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <P15_CBI_F24_EP_RECORD_A> TYPE P15_CBI_F24_EP_RECORD_A. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_P15_CBI_F24_EP_RECORD_A. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM P15_CBI_F24_EP_RECORD_A INTO TABLE IT_P15_CBI_F24_EP_RECORD_A. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM P15_CBI_F24_EP_RECORD_A * INTO TABLE @DATA(IT_P15_CBI_F24_EP_RECORD_A2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_P15_CBI_F24_EP_RECORD_A INDEX 1 INTO DATA(WA_P15_CBI_F24_EP_RECORD_A2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_P15_CBI_F24_EP_RECORD_A ASSIGNING <P15_CBI_F24_EP_RECORD_A>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<P15_CBI_F24_EP_RECORD_A>-TIPORECORD = 1.
<P15_CBI_F24_EP_RECORD_A>-FILLER1 = 1.
<P15_CBI_F24_EP_RECORD_A>-CODFORN = 1.
<P15_CBI_F24_EP_RECORD_A>-TIPOFORN = 1.
<P15_CBI_F24_EP_RECORD_A>-CODFISC = 1.
ENDLOOP. LOOP AT IT_P15_CBI_F24_EP_RECORD_A INTO WA_P15_CBI_F24_EP_RECORD_A. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P15_CBI_F24_EP_RECORD_A-FILLER2, sy-vline,
WA_P15_CBI_F24_EP_RECORD_A-DENOM, sy-vline,
WA_P15_CBI_F24_EP_RECORD_A-FILLER3, sy-vline,
WA_P15_CBI_F24_EP_RECORD_A-FLAGORIG, sy-vline,
WA_P15_CBI_F24_EP_RECORD_A-RISERV1, sy-vline,
WA_P15_CBI_F24_EP_RECORD_A-FILLER4, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P15_CBI_F24_EP_RECORD_A you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P15_CBI_F24_EP_RECORD_A TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P15_CBI_F24_EP_RECORD_A INTO WA_P15_CBI_F24_EP_RECORD_A. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P15_CBI_F24_EP_RECORD_A_STR,
TIPORECORD TYPE STRING,
FILLER1 TYPE STRING,
CODFORN TYPE STRING,
TIPOFORN TYPE STRING,
CODFISC TYPE STRING,
FILLER2 TYPE STRING,
DENOM TYPE STRING,
FILLER3 TYPE STRING,
FLAGORIG TYPE STRING,
RISERV1 TYPE STRING,
FILLER4 TYPE STRING,
PROGRES TYPE STRING,
NUMTOTAL TYPE STRING,
CAMUTE TYPE STRING,
FLAGACC TYPE STRING,
RISERV2 TYPE STRING,
SEMPREA TYPE STRING,END OF T_EKKO_STR. DATA: WA_P15_CBI_F24_EP_RECORD_A_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-TIPORECORD sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-FILLER1 sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-CODFORN sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-TIPOFORN sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-CODFISC sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-FILLER2 sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-DENOM sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-FILLER3 sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-FLAGORIG sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-RISERV1 sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-FILLER4 sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-PROGRES sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-NUMTOTAL sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-CAMUTE sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-FLAGACC sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-RISERV2 sy-vline
WA_P15_CBI_F24_EP_RECORD_A_STR-SEMPREA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.