ABAP Select data from SAP table P2IE_CPRSI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P2IE_CPRSI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P2IE_CPRSI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P2IE_CPRSI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P2IE_CPRSI TYPE STANDARD TABLE OF P2IE_CPRSI,
      WA_P2IE_CPRSI TYPE P2IE_CPRSI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P2IE_CPRSI> TYPE P2IE_CPRSI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P2IE_CPRSI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P2IE_CPRSI
  INTO TABLE IT_P2IE_CPRSI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P2IE_CPRSI
*  INTO TABLE @DATA(IT_P2IE_CPRSI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P2IE_CPRSI INDEX 1 INTO DATA(WA_P2IE_CPRSI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P2IE_CPRSI ASSIGNING <P2IE_CPRSI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P2IE_CPRSI>-MANDT = 1.
<P2IE_CPRSI>-DCT_PERNR = 1.
<P2IE_CPRSI>-DCT_SEQNR = 1.
<P2IE_CPRSI>-DCT_ROWID = 1.
<P2IE_CPRSI>-BEGDA = 1.
ENDLOOP.

LOOP AT IT_P2IE_CPRSI INTO WA_P2IE_CPRSI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P2IE_CPRSI-ENDDA, sy-vline,
WA_P2IE_CPRSI-PRSIA, sy-vline,
WA_P2IE_CPRSI-STAT2, sy-vline,
WA_P2IE_CPRSI-WEEKS, sy-vline,
WA_P2IE_CPRSI-NWUPL, sy-vline,
WA_P2IE_CPRSI-PRAMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P2IE_CPRSI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P2IE_CPRSI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P2IE_CPRSI INTO WA_P2IE_CPRSI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P2IE_CPRSI_STR,
MANDT TYPE STRING,
DCT_PERNR TYPE STRING,
DCT_SEQNR TYPE STRING,
DCT_ROWID TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PRSIA TYPE STRING,
STAT2 TYPE STRING,
WEEKS TYPE STRING,
NWUPL TYPE STRING,
PRAMT TYPE STRING,
EECON TYPE STRING,
ERCON TYPE STRING,
TOCON TYPE STRING,
FASLV TYPE STRING,END OF T_EKKO_STR. DATA: WA_P2IE_CPRSI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P2IE_CPRSI_STR-MANDT sy-vline
WA_P2IE_CPRSI_STR-DCT_PERNR sy-vline
WA_P2IE_CPRSI_STR-DCT_SEQNR sy-vline
WA_P2IE_CPRSI_STR-DCT_ROWID sy-vline
WA_P2IE_CPRSI_STR-BEGDA sy-vline
WA_P2IE_CPRSI_STR-ENDDA sy-vline
WA_P2IE_CPRSI_STR-PRSIA sy-vline
WA_P2IE_CPRSI_STR-STAT2 sy-vline
WA_P2IE_CPRSI_STR-WEEKS sy-vline
WA_P2IE_CPRSI_STR-NWUPL sy-vline
WA_P2IE_CPRSI_STR-PRAMT sy-vline
WA_P2IE_CPRSI_STR-EECON sy-vline
WA_P2IE_CPRSI_STR-ERCON sy-vline
WA_P2IE_CPRSI_STR-TOCON sy-vline
WA_P2IE_CPRSI_STR-FASLV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.