ABAP Select data from SAP table PACMP_DYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PACMP_DYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PACMP_DYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PACMP_DYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PACMP_DYNP TYPE STANDARD TABLE OF PACMP_DYNP,
      WA_PACMP_DYNP TYPE PACMP_DYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PACMP_DYNP> TYPE PACMP_DYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PACMP_DYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PACMP_DYNP
  INTO TABLE IT_PACMP_DYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PACMP_DYNP
*  INTO TABLE @DATA(IT_PACMP_DYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PACMP_DYNP INDEX 1 INTO DATA(WA_PACMP_DYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PACMP_DYNP ASSIGNING <PACMP_DYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PACMP_DYNP>-MARK = 1.
<PACMP_DYNP>-ARCHIVE = 1.
<PACMP_DYNP>-MANDT = 1.
<PACMP_DYNP>-PAGUID = 1.
<PACMP_DYNP>-OTYPE = 1.
ENDLOOP.

LOOP AT IT_PACMP_DYNP INTO WA_PACMP_DYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PACMP_DYNP-PGUID, sy-vline,
WA_PACMP_DYNP-ALTNUM, sy-vline,
WA_PACMP_DYNP-PATYPE, sy-vline,
WA_PACMP_DYNP-APPLOBJ_TYPE, sy-vline,
WA_PACMP_DYNP-TIMSTMP, sy-vline,
WA_PACMP_DYNP-HISTFLG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PACMP_DYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PACMP_DYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PACMP_DYNP INTO WA_PACMP_DYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ALTNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PACMP_DYNP-ALTNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PACMP_DYNP-ALTNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PACMP_DYNP-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PACMP_DYNP-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REF_ALTNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PACMP_DYNP-REF_ALTNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PACMP_DYNP-REF_ALTNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PACMP_DYNP_STR,
MARK TYPE STRING,
ARCHIVE TYPE STRING,
MANDT TYPE STRING,
PAGUID TYPE STRING,
OTYPE TYPE STRING,
PGUID TYPE STRING,
ALTNUM TYPE STRING,
PATYPE TYPE STRING,
APPLOBJ_TYPE TYPE STRING,
TIMSTMP TYPE STRING,
HISTFLG TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
LOGSYS TYPE STRING,
DOCALTCMP TYPE STRING,
OTYPECMP TYPE STRING,
PGUIDCMP TYPE STRING,
PATEXT TYPE STRING,
REF_ALTNUM TYPE STRING,
REF_PNAME TYPE STRING,
REF_PNTYPE TYPE STRING,
TXTFLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_PACMP_DYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PACMP_DYNP_STR-MARK sy-vline
WA_PACMP_DYNP_STR-ARCHIVE sy-vline
WA_PACMP_DYNP_STR-MANDT sy-vline
WA_PACMP_DYNP_STR-PAGUID sy-vline
WA_PACMP_DYNP_STR-OTYPE sy-vline
WA_PACMP_DYNP_STR-PGUID sy-vline
WA_PACMP_DYNP_STR-ALTNUM sy-vline
WA_PACMP_DYNP_STR-PATYPE sy-vline
WA_PACMP_DYNP_STR-APPLOBJ_TYPE sy-vline
WA_PACMP_DYNP_STR-TIMSTMP sy-vline
WA_PACMP_DYNP_STR-HISTFLG sy-vline
WA_PACMP_DYNP_STR-CREADAT sy-vline
WA_PACMP_DYNP_STR-CREABY sy-vline
WA_PACMP_DYNP_STR-CHNGDAT sy-vline
WA_PACMP_DYNP_STR-CHNGBY sy-vline
WA_PACMP_DYNP_STR-LOGSYS sy-vline
WA_PACMP_DYNP_STR-DOCALTCMP sy-vline
WA_PACMP_DYNP_STR-OTYPECMP sy-vline
WA_PACMP_DYNP_STR-PGUIDCMP sy-vline
WA_PACMP_DYNP_STR-PATEXT sy-vline
WA_PACMP_DYNP_STR-REF_ALTNUM sy-vline
WA_PACMP_DYNP_STR-REF_PNAME sy-vline
WA_PACMP_DYNP_STR-REF_PNTYPE sy-vline
WA_PACMP_DYNP_STR-TXTFLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.