ABAP Select data from SAP table PAR52 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PAR52 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PAR52. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PAR52 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PAR52 TYPE STANDARD TABLE OF PAR52, WA_PAR52 TYPE PAR52, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PAR52> TYPE PAR52. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PAR52. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PAR52 INTO TABLE IT_PAR52. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PAR52 * INTO TABLE @DATA(IT_PAR522). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PAR52 INDEX 1 INTO DATA(WA_PAR522). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PAR52 ASSIGNING <PAR52>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PAR52>-TOTAL = 1.
<PAR52>-BUKRS = 1.
<PAR52>-BUTXT = 1.
<PAR52>-REGIS = 1.
<PAR52>-PERNR = 1.
ENDLOOP. LOOP AT IT_PAR52 INTO WA_PAR52. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PAR52-RETOT, sy-vline,
WA_PAR52-AMT_CURR_TOT, sy-vline,
WA_PAR52-REAOS, sy-vline,
WA_PAR52-AMT_CURR_REA, sy-vline,
WA_PAR52-REICO, sy-vline,
WA_PAR52-AMT_CURR_REI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PAR52 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PAR52 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PAR52 INTO WA_PAR52. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PAR52_STR,
TOTAL TYPE STRING,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
REGIS TYPE STRING,
PERNR TYPE STRING,
RETOT TYPE STRING,
AMT_CURR_TOT TYPE STRING,
REAOS TYPE STRING,
AMT_CURR_REA TYPE STRING,
REICO TYPE STRING,
AMT_CURR_REI TYPE STRING,
REIM3 TYPE STRING,
AMT_CURR_RE3 TYPE STRING,
REIOS TYPE STRING,
AMT_CURR_REO TYPE STRING,
APJVO TYPE STRING,
BETPE_JVO TYPE STRING,
RTE_CURR_JVO TYPE STRING,
AMT_CURR_JVO TYPE STRING,
ASFAM TYPE STRING,
BETPE_ASF TYPE STRING,
RTE_CURR_ASF TYPE STRING,
AMT_CURR_ASF TYPE STRING,
IADOS TYPE STRING,
AMT_CURR_IAD TYPE STRING,
EXASS TYPE STRING,
AMT_CURR_EXA TYPE STRING,
EXAOS TYPE STRING,
AMT_CURR_EXO TYPE STRING,
TIKET TYPE STRING,
AMT_CURR_TIK TYPE STRING,
CAPRE TYPE STRING,
AMT_CURR_CAP TYPE STRING,
CCUIL TYPE STRING,
NOMAP TYPE STRING,
CONTF TYPE STRING,
HIJOS TYPE STRING,
SITUA TYPE STRING,
CONDI TYPE STRING,
ACTSI TYPE STRING,
ZONDI TYPE STRING,
AADSS TYPE STRING,
TCSIJ TYPE STRING,
OBRAS TYPE STRING,
ADHER TYPE STRING,
LOCTX TYPE STRING,
SINSI TYPE STRING,
CORSI TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
TIPEM TYPE STRING,
APAOS TYPE STRING,
AMT_CURR_APS TYPE STRING,
REJUB TYPE STRING,
SITU1 TYPE STRING,
SITD1 TYPE STRING,
SITU2 TYPE STRING,
SITD2 TYPE STRING,
SITU3 TYPE STRING,
SITD3 TYPE STRING,
SUESI TYPE STRING,
AMT_CURR_SUE TYPE STRING,
SACSI TYPE STRING,
AMT_CURR_SAC TYPE STRING,
HEXSI TYPE STRING,
AMT_CURR_HEX TYPE STRING,
ZDESI TYPE STRING,
AMT_CURR_ZDE TYPE STRING,
VACSI TYPE STRING,
AMT_CURR_VAC TYPE STRING,
DTRSI TYPE STRING,
REIM5 TYPE STRING,
AMT_CURR_RE5 TYPE STRING,
CNVSI TYPE STRING,
REIM6 TYPE STRING,
AMT_CURR_RE6 TYPE STRING,
TIPOP TYPE STRING,
ADCNL TYPE STRING,
AMT_CURR_ADC TYPE STRING,
PREMS TYPE STRING,
AMT_CURR_PRM TYPE STRING,
R7885 TYPE STRING,
AMT_CURR_788 TYPE STRING,
REIM7 TYPE STRING,
AMT_CURR_RE7 TYPE STRING,
CAHEX TYPE STRING,
RNORE TYPE STRING,
AMT_CURR_NRE TYPE STRING,
REMAT TYPE STRING,
AMT_CURR_MAT TYPE STRING,
RRECT TYPE STRING,
AMT_CURR_RCT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PAR52_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PAR52_STR-TOTAL sy-vline
WA_PAR52_STR-BUKRS sy-vline
WA_PAR52_STR-BUTXT sy-vline
WA_PAR52_STR-REGIS sy-vline
WA_PAR52_STR-PERNR sy-vline
WA_PAR52_STR-RETOT sy-vline
WA_PAR52_STR-AMT_CURR_TOT sy-vline
WA_PAR52_STR-REAOS sy-vline
WA_PAR52_STR-AMT_CURR_REA sy-vline
WA_PAR52_STR-REICO sy-vline
WA_PAR52_STR-AMT_CURR_REI sy-vline
WA_PAR52_STR-REIM3 sy-vline
WA_PAR52_STR-AMT_CURR_RE3 sy-vline
WA_PAR52_STR-REIOS sy-vline
WA_PAR52_STR-AMT_CURR_REO sy-vline
WA_PAR52_STR-APJVO sy-vline
WA_PAR52_STR-BETPE_JVO sy-vline
WA_PAR52_STR-RTE_CURR_JVO sy-vline
WA_PAR52_STR-AMT_CURR_JVO sy-vline
WA_PAR52_STR-ASFAM sy-vline
WA_PAR52_STR-BETPE_ASF sy-vline
WA_PAR52_STR-RTE_CURR_ASF sy-vline
WA_PAR52_STR-AMT_CURR_ASF sy-vline
WA_PAR52_STR-IADOS sy-vline
WA_PAR52_STR-AMT_CURR_IAD sy-vline
WA_PAR52_STR-EXASS sy-vline
WA_PAR52_STR-AMT_CURR_EXA sy-vline
WA_PAR52_STR-EXAOS sy-vline
WA_PAR52_STR-AMT_CURR_EXO sy-vline
WA_PAR52_STR-TIKET sy-vline
WA_PAR52_STR-AMT_CURR_TIK sy-vline
WA_PAR52_STR-CAPRE sy-vline
WA_PAR52_STR-AMT_CURR_CAP sy-vline
WA_PAR52_STR-CCUIL sy-vline
WA_PAR52_STR-NOMAP sy-vline
WA_PAR52_STR-CONTF sy-vline
WA_PAR52_STR-HIJOS sy-vline
WA_PAR52_STR-SITUA sy-vline
WA_PAR52_STR-CONDI sy-vline
WA_PAR52_STR-ACTSI sy-vline
WA_PAR52_STR-ZONDI sy-vline
WA_PAR52_STR-AADSS sy-vline
WA_PAR52_STR-TCSIJ sy-vline
WA_PAR52_STR-OBRAS sy-vline
WA_PAR52_STR-ADHER sy-vline
WA_PAR52_STR-LOCTX sy-vline
WA_PAR52_STR-SINSI sy-vline
WA_PAR52_STR-CORSI sy-vline
WA_PAR52_STR-BEGDA sy-vline
WA_PAR52_STR-ENDDA sy-vline
WA_PAR52_STR-TIPEM sy-vline
WA_PAR52_STR-APAOS sy-vline
WA_PAR52_STR-AMT_CURR_APS sy-vline
WA_PAR52_STR-REJUB sy-vline
WA_PAR52_STR-SITU1 sy-vline
WA_PAR52_STR-SITD1 sy-vline
WA_PAR52_STR-SITU2 sy-vline
WA_PAR52_STR-SITD2 sy-vline
WA_PAR52_STR-SITU3 sy-vline
WA_PAR52_STR-SITD3 sy-vline
WA_PAR52_STR-SUESI sy-vline
WA_PAR52_STR-AMT_CURR_SUE sy-vline
WA_PAR52_STR-SACSI sy-vline
WA_PAR52_STR-AMT_CURR_SAC sy-vline
WA_PAR52_STR-HEXSI sy-vline
WA_PAR52_STR-AMT_CURR_HEX sy-vline
WA_PAR52_STR-ZDESI sy-vline
WA_PAR52_STR-AMT_CURR_ZDE sy-vline
WA_PAR52_STR-VACSI sy-vline
WA_PAR52_STR-AMT_CURR_VAC sy-vline
WA_PAR52_STR-DTRSI sy-vline
WA_PAR52_STR-REIM5 sy-vline
WA_PAR52_STR-AMT_CURR_RE5 sy-vline
WA_PAR52_STR-CNVSI sy-vline
WA_PAR52_STR-REIM6 sy-vline
WA_PAR52_STR-AMT_CURR_RE6 sy-vline
WA_PAR52_STR-TIPOP sy-vline
WA_PAR52_STR-ADCNL sy-vline
WA_PAR52_STR-AMT_CURR_ADC sy-vline
WA_PAR52_STR-PREMS sy-vline
WA_PAR52_STR-AMT_CURR_PRM sy-vline
WA_PAR52_STR-R7885 sy-vline
WA_PAR52_STR-AMT_CURR_788 sy-vline
WA_PAR52_STR-REIM7 sy-vline
WA_PAR52_STR-AMT_CURR_RE7 sy-vline
WA_PAR52_STR-CAHEX sy-vline
WA_PAR52_STR-RNORE sy-vline
WA_PAR52_STR-AMT_CURR_NRE sy-vline
WA_PAR52_STR-REMAT sy-vline
WA_PAR52_STR-AMT_CURR_MAT sy-vline
WA_PAR52_STR-RRECT sy-vline
WA_PAR52_STR-AMT_CURR_RCT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.