ABAP Select data from SAP table PAT05 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PAT05 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PAT05. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PAT05 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PAT05 TYPE STANDARD TABLE OF PAT05, WA_PAT05 TYPE PAT05, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PAT05> TYPE PAT05. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PAT05. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PAT05 INTO TABLE IT_PAT05. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PAT05 * INTO TABLE @DATA(IT_PAT052). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PAT05 INDEX 1 INTO DATA(WA_PAT052). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PAT05 ASSIGNING <PAT05>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PAT05>-SYSID = 1.
<PAT05>-EPS_MON = 1.
<PAT05>-SCENARIO = 1.
<PAT05>-SCENARIO_AO = 1.
<PAT05>-GENERATE = 1.
ENDLOOP. LOOP AT IT_PAT05 INTO WA_PAT05. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PAT05-BACKUP, sy-vline,
WA_PAT05-CREATE_DF, sy-vline,
WA_PAT05-SAVE_DF, sy-vline,
WA_PAT05-DISP_CONT, sy-vline,
WA_PAT05-START_DIR, sy-vline,
WA_PAT05-SAVE_LAST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PAT05 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PAT05 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PAT05 INTO WA_PAT05. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PAT05_STR,
SYSID TYPE STRING,
EPS_MON TYPE STRING,
SCENARIO TYPE STRING,
SCENARIO_AO TYPE STRING,
GENERATE TYPE STRING,
BACKUP TYPE STRING,
CREATE_DF TYPE STRING,
SAVE_DF TYPE STRING,
DISP_CONT TYPE STRING,
START_DIR TYPE STRING,
SAVE_LAST TYPE STRING,
DEL_FILE TYPE STRING,
INACT_IMP TYPE STRING,
C_MODE TYPE STRING,
CREATE_VRS TYPE STRING,
ONE_PATCH TYPE STRING,
HELP01 TYPE STRING,
INACTIMPAO TYPE STRING,
HELP02 TYPE STRING,
MIMPPRC_AO TYPE STRING,
BTCHPRC_AO TYPE STRING,
QUEUE_CALC TYPE STRING,
MODADJ_BND TYPE STRING,
AUTO_SPAU TYPE STRING,
DISP_INACT TYPE STRING,
DISP_UNUSD TYPE STRING,
REQ_SFXREP TYPE STRING,
SMP_USER TYPE STRING,
R3TRANSPRC TYPE STRING,
HELP03 TYPE STRING,
HELP04 TYPE STRING,
DDIC_ACT_SUBSET TYPE STRING,
INT_CCHECK TYPE STRING,
NO_STDXPRA TYPE STRING,
RTA_SNDFRM TYPE STRING,
RTA_SYSTYP TYPE STRING,
RTA_CNTACT TYPE STRING,
SKIPCONDITIONSUM TYPE STRING,
NO_SIG_CHECK TYPE STRING,
SKIPCONDITION TYPE STRING,
NO_STOP_RC6 TYPE STRING,
IMP_SIG_CHECK TYPE STRING,
FREEZE_UPDATE TYPE STRING,
NO_AIM_REPEAT TYPE STRING,
CVOI_TIMEOUT TYPE STRING,
IGNORE_SDC TYPE STRING,END OF T_EKKO_STR. DATA: WA_PAT05_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PAT05_STR-SYSID sy-vline
WA_PAT05_STR-EPS_MON sy-vline
WA_PAT05_STR-SCENARIO sy-vline
WA_PAT05_STR-SCENARIO_AO sy-vline
WA_PAT05_STR-GENERATE sy-vline
WA_PAT05_STR-BACKUP sy-vline
WA_PAT05_STR-CREATE_DF sy-vline
WA_PAT05_STR-SAVE_DF sy-vline
WA_PAT05_STR-DISP_CONT sy-vline
WA_PAT05_STR-START_DIR sy-vline
WA_PAT05_STR-SAVE_LAST sy-vline
WA_PAT05_STR-DEL_FILE sy-vline
WA_PAT05_STR-INACT_IMP sy-vline
WA_PAT05_STR-C_MODE sy-vline
WA_PAT05_STR-CREATE_VRS sy-vline
WA_PAT05_STR-ONE_PATCH sy-vline
WA_PAT05_STR-HELP01 sy-vline
WA_PAT05_STR-INACTIMPAO sy-vline
WA_PAT05_STR-HELP02 sy-vline
WA_PAT05_STR-MIMPPRC_AO sy-vline
WA_PAT05_STR-BTCHPRC_AO sy-vline
WA_PAT05_STR-QUEUE_CALC sy-vline
WA_PAT05_STR-MODADJ_BND sy-vline
WA_PAT05_STR-AUTO_SPAU sy-vline
WA_PAT05_STR-DISP_INACT sy-vline
WA_PAT05_STR-DISP_UNUSD sy-vline
WA_PAT05_STR-REQ_SFXREP sy-vline
WA_PAT05_STR-SMP_USER sy-vline
WA_PAT05_STR-R3TRANSPRC sy-vline
WA_PAT05_STR-HELP03 sy-vline
WA_PAT05_STR-HELP04 sy-vline
WA_PAT05_STR-DDIC_ACT_SUBSET sy-vline
WA_PAT05_STR-INT_CCHECK sy-vline
WA_PAT05_STR-NO_STDXPRA sy-vline
WA_PAT05_STR-RTA_SNDFRM sy-vline
WA_PAT05_STR-RTA_SYSTYP sy-vline
WA_PAT05_STR-RTA_CNTACT sy-vline
WA_PAT05_STR-SKIPCONDITIONSUM sy-vline
WA_PAT05_STR-NO_SIG_CHECK sy-vline
WA_PAT05_STR-SKIPCONDITION sy-vline
WA_PAT05_STR-NO_STOP_RC6 sy-vline
WA_PAT05_STR-IMP_SIG_CHECK sy-vline
WA_PAT05_STR-FREEZE_UPDATE sy-vline
WA_PAT05_STR-NO_AIM_REPEAT sy-vline
WA_PAT05_STR-CVOI_TIMEOUT sy-vline
WA_PAT05_STR-IGNORE_SDC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.