ABAP Select data from SAP table PC217 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC217 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC217. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PC217 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PC217 TYPE STANDARD TABLE OF PC217, WA_PC217 TYPE PC217, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PC217> TYPE PC217. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PC217. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PC217 INTO TABLE IT_PC217. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PC217 * INTO TABLE @DATA(IT_PC2172). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PC217 INDEX 1 INTO DATA(WA_PC2172). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PC217 ASSIGNING <PC217>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC217>-LANSP = 1.
<PC217>-BEGDA = 1.
<PC217>-ENDDA = 1.
<PC217>-CCOBT = 1.
<PC217>-CFIZZ = 1.
ENDLOOP. LOOP AT IT_PC217 INTO WA_PC217. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PC217-IREAP, sy-vline,
WA_PC217-CIINV, sy-vline,
WA_PC217-IAOUK, sy-vline,
WA_PC217-CAARD, sy-vline,
WA_PC217-CAOCL, sy-vline,
WA_PC217-AANVU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC217 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC217 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC217 INTO WA_PC217. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC217_STR,
LANSP TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
CCOBT TYPE STRING,
CFIZZ TYPE STRING,
IREAP TYPE STRING,
CIINV TYPE STRING,
IAOUK TYPE STRING,
CAARD TYPE STRING,
CAOCL TYPE STRING,
AANVU TYPE STRING,
CREIF TYPE STRING,
VERWE TYPE STRING,
VANGN TYPE STRING,
CFIFZ TYPE STRING,
CIVPL TYPE STRING,
INDDA TYPE STRING,
UITDA TYPE STRING,
CDAGH TYPE STRING,
CRGBA TYPE STRING,
NUMIV TYPE STRING,
BEGLL TYPE STRING,
ENDLL TYPE STRING,
RATLT TYPE STRING,
RATLB TYPE STRING,
TAXGR TYPE STRING,
ZVWIS TYPE STRING,
ZVWIR TYPE STRING,
DUMMY TYPE STRING,
IRSBD TYPE STRING,
IRSED TYPE STRING,
IRSTP TYPE STRING,
RATLC TYPE STRING,
COHRS TYPE STRING,
COWGE TYPE STRING,
NORSK TYPE STRING,
WSWA7 TYPE STRING,
JOBAG TYPE STRING,
MINWE TYPE STRING,
CAOCT TYPE STRING,
CREAO TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC217_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC217_STR-LANSP sy-vline
WA_PC217_STR-BEGDA sy-vline
WA_PC217_STR-ENDDA sy-vline
WA_PC217_STR-CCOBT sy-vline
WA_PC217_STR-CFIZZ sy-vline
WA_PC217_STR-IREAP sy-vline
WA_PC217_STR-CIINV sy-vline
WA_PC217_STR-IAOUK sy-vline
WA_PC217_STR-CAARD sy-vline
WA_PC217_STR-CAOCL sy-vline
WA_PC217_STR-AANVU sy-vline
WA_PC217_STR-CREIF sy-vline
WA_PC217_STR-VERWE sy-vline
WA_PC217_STR-VANGN sy-vline
WA_PC217_STR-CFIFZ sy-vline
WA_PC217_STR-CIVPL sy-vline
WA_PC217_STR-INDDA sy-vline
WA_PC217_STR-UITDA sy-vline
WA_PC217_STR-CDAGH sy-vline
WA_PC217_STR-CRGBA sy-vline
WA_PC217_STR-NUMIV sy-vline
WA_PC217_STR-BEGLL sy-vline
WA_PC217_STR-ENDLL sy-vline
WA_PC217_STR-RATLT sy-vline
WA_PC217_STR-RATLB sy-vline
WA_PC217_STR-TAXGR sy-vline
WA_PC217_STR-ZVWIS sy-vline
WA_PC217_STR-ZVWIR sy-vline
WA_PC217_STR-DUMMY sy-vline
WA_PC217_STR-IRSBD sy-vline
WA_PC217_STR-IRSED sy-vline
WA_PC217_STR-IRSTP sy-vline
WA_PC217_STR-RATLC sy-vline
WA_PC217_STR-COHRS sy-vline
WA_PC217_STR-COWGE sy-vline
WA_PC217_STR-NORSK sy-vline
WA_PC217_STR-WSWA7 sy-vline
WA_PC217_STR-JOBAG sy-vline
WA_PC217_STR-MINWE sy-vline
WA_PC217_STR-CAOCT sy-vline
WA_PC217_STR-CREAO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.