ABAP Select data from SAP table PC21W into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC21W table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC21W. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC21W table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC21W TYPE STANDARD TABLE OF PC21W,
      WA_PC21W TYPE PC21W,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC21W> TYPE PC21W.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC21W.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC21W
  INTO TABLE IT_PC21W.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC21W
*  INTO TABLE @DATA(IT_PC21W2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC21W INDEX 1 INTO DATA(WA_PC21W2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC21W ASSIGNING <PC21W>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC21W>-RVNUM = 1.
<PC21W>-SAKEN = 1.
<PC21W>-VTRAE = 1.
<PC21W>-ABEGJ = 1.
<PC21W>-ABEGD = 1.
ENDLOOP.

LOOP AT IT_PC21W INTO WA_PC21W.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC21W-AENDD, sy-vline,
WA_PC21W-AENTG, sy-vline,
WA_PC21W-AABGR, sy-vline,
WA_PC21W-BEGJD, sy-vline,
WA_PC21W-BEGDD, sy-vline,
WA_PC21W-ENDDD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC21W you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC21W TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC21W INTO WA_PC21W. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC21W_STR,
RVNUM TYPE STRING,
SAKEN TYPE STRING,
VTRAE TYPE STRING,
ABEGJ TYPE STRING,
ABEGD TYPE STRING,
AENDD TYPE STRING,
AENTG TYPE STRING,
AABGR TYPE STRING,
BEGJD TYPE STRING,
BEGDD TYPE STRING,
ENDDD TYPE STRING,
ENTGT TYPE STRING,
ABGRD TYPE STRING,
RVSCH TYPE STRING,
FILL1 TYPE STRING,
PERNR TYPE STRING,
IDENT TYPE STRING,
BNRAS TYPE STRING,
NACHN TYPE STRING,
VORNA TYPE STRING,
BNRKK TYPE STRING,
LEER1 TYPE STRING,
AENBJ TYPE STRING,
AENBD TYPE STRING,
ENBJD TYPE STRING,
ENBDD TYPE STRING,
LEER3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC21W_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC21W_STR-RVNUM sy-vline
WA_PC21W_STR-SAKEN sy-vline
WA_PC21W_STR-VTRAE sy-vline
WA_PC21W_STR-ABEGJ sy-vline
WA_PC21W_STR-ABEGD sy-vline
WA_PC21W_STR-AENDD sy-vline
WA_PC21W_STR-AENTG sy-vline
WA_PC21W_STR-AABGR sy-vline
WA_PC21W_STR-BEGJD sy-vline
WA_PC21W_STR-BEGDD sy-vline
WA_PC21W_STR-ENDDD sy-vline
WA_PC21W_STR-ENTGT sy-vline
WA_PC21W_STR-ABGRD sy-vline
WA_PC21W_STR-RVSCH sy-vline
WA_PC21W_STR-FILL1 sy-vline
WA_PC21W_STR-PERNR sy-vline
WA_PC21W_STR-IDENT sy-vline
WA_PC21W_STR-BNRAS sy-vline
WA_PC21W_STR-NACHN sy-vline
WA_PC21W_STR-VORNA sy-vline
WA_PC21W_STR-BNRKK sy-vline
WA_PC21W_STR-LEER1 sy-vline
WA_PC21W_STR-AENBJ sy-vline
WA_PC21W_STR-AENBD sy-vline
WA_PC21W_STR-ENBJD sy-vline
WA_PC21W_STR-ENBDD sy-vline
WA_PC21W_STR-LEER3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.