ABAP Select data from SAP table PC223 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC223 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC223. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PC223 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PC223 TYPE STANDARD TABLE OF PC223, WA_PC223 TYPE PC223, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PC223> TYPE PC223. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PC223. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PC223 INTO TABLE IT_PC223. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PC223 * INTO TABLE @DATA(IT_PC2232). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PC223 INDEX 1 INTO DATA(WA_PC2232). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PC223 ASSIGNING <PC223>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC223>-CNTR1 = 1.
<PC223>-BEGDA = 1.
<PC223>-ENDDA = 1.
<PC223>-NUMSS = 1.
<PC223>-CLESS = 1.
ENDLOOP. LOOP AT IT_PC223 INTO WA_PC223. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PC223-TPART, sy-vline,
WA_PC223-REGNO, sy-vline,
WA_PC223-ORG01, sy-vline,
WA_PC223-COT01, sy-vline,
WA_PC223-ORG02, sy-vline,
WA_PC223-COT02, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC223 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC223 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC223 INTO WA_PC223. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC223_STR,
CNTR1 TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
NUMSS TYPE STRING,
CLESS TYPE STRING,
TPART TYPE STRING,
REGNO TYPE STRING,
ORG01 TYPE STRING,
COT01 TYPE STRING,
ORG02 TYPE STRING,
COT02 TYPE STRING,
ORG03 TYPE STRING,
COT03 TYPE STRING,
ORG04 TYPE STRING,
COT04 TYPE STRING,
ORG05 TYPE STRING,
COT05 TYPE STRING,
ORG06 TYPE STRING,
COT06 TYPE STRING,
ORG07 TYPE STRING,
COT07 TYPE STRING,
ORG08 TYPE STRING,
COT08 TYPE STRING,
ORG09 TYPE STRING,
COT09 TYPE STRING,
ORG10 TYPE STRING,
COT10 TYPE STRING,
REGSS TYPE STRING,
REGAC TYPE STRING,
REGRT TYPE STRING,
CTTYP TYPE STRING,
MRCDD TYPE STRING,
CASPA TYPE STRING,
INBEG TYPE STRING,
INEND TYPE STRING,
PREND TYPE STRING,
CATDU TYPE STRING,
PEEND TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC223_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC223_STR-CNTR1 sy-vline
WA_PC223_STR-BEGDA sy-vline
WA_PC223_STR-ENDDA sy-vline
WA_PC223_STR-NUMSS sy-vline
WA_PC223_STR-CLESS sy-vline
WA_PC223_STR-TPART sy-vline
WA_PC223_STR-REGNO sy-vline
WA_PC223_STR-ORG01 sy-vline
WA_PC223_STR-COT01 sy-vline
WA_PC223_STR-ORG02 sy-vline
WA_PC223_STR-COT02 sy-vline
WA_PC223_STR-ORG03 sy-vline
WA_PC223_STR-COT03 sy-vline
WA_PC223_STR-ORG04 sy-vline
WA_PC223_STR-COT04 sy-vline
WA_PC223_STR-ORG05 sy-vline
WA_PC223_STR-COT05 sy-vline
WA_PC223_STR-ORG06 sy-vline
WA_PC223_STR-COT06 sy-vline
WA_PC223_STR-ORG07 sy-vline
WA_PC223_STR-COT07 sy-vline
WA_PC223_STR-ORG08 sy-vline
WA_PC223_STR-COT08 sy-vline
WA_PC223_STR-ORG09 sy-vline
WA_PC223_STR-COT09 sy-vline
WA_PC223_STR-ORG10 sy-vline
WA_PC223_STR-COT10 sy-vline
WA_PC223_STR-REGSS sy-vline
WA_PC223_STR-REGAC sy-vline
WA_PC223_STR-REGRT sy-vline
WA_PC223_STR-CTTYP sy-vline
WA_PC223_STR-MRCDD sy-vline
WA_PC223_STR-CASPA sy-vline
WA_PC223_STR-INBEG sy-vline
WA_PC223_STR-INEND sy-vline
WA_PC223_STR-PREND sy-vline
WA_PC223_STR-CATDU sy-vline
WA_PC223_STR-PEEND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.