ABAP Select data from SAP table PC22K into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC22K table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC22K. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PC22K table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PC22K TYPE STANDARD TABLE OF PC22K, WA_PC22K TYPE PC22K, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PC22K> TYPE PC22K. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PC22K. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PC22K INTO TABLE IT_PC22K. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PC22K * INTO TABLE @DATA(IT_PC22K2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PC22K INDEX 1 INTO DATA(WA_PC22K2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PC22K ASSIGNING <PC22K>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC22K>-CNTR1 = 1.
<PC22K>-BEGDA = 1.
<PC22K>-ENDDA = 1.
<PC22K>-JUPER = 1.
<PC22K>-KVKZ1 = 1.
ENDLOOP. LOOP AT IT_PC22K INTO WA_PC22K. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PC22K-RVKZ1, sy-vline,
WA_PC22K-AVKZ1, sy-vline,
WA_PC22K-RVNUM, sy-vline,
WA_PC22K-KVSFR, sy-vline,
WA_PC22K-KVGST, sy-vline,
WA_PC22K-KVBKL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC22K you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC22K TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC22K INTO WA_PC22K. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC22K_STR,
CNTR1 TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
JUPER TYPE STRING,
KVKZ1 TYPE STRING,
RVKZ1 TYPE STRING,
AVKZ1 TYPE STRING,
RVNUM TYPE STRING,
KVSFR TYPE STRING,
KVGST TYPE STRING,
KVBKL TYPE STRING,
KVFBT TYPE STRING,
ZUSKA TYPE STRING,
SONKV TYPE STRING,
SONRV TYPE STRING,
SONAV TYPE STRING,
SELKV TYPE STRING,
SELRV TYPE STRING,
MITNR TYPE STRING,
MAXKV TYPE STRING,
KVBAT TYPE STRING,
RVBAT TYPE STRING,
AVBAT TYPE STRING,
SVA01 TYPE STRING,
SVA02 TYPE STRING,
SVA03 TYPE STRING,
SVA04 TYPE STRING,
SVA05 TYPE STRING,
SVA06 TYPE STRING,
SVA07 TYPE STRING,
SVA08 TYPE STRING,
PVKZ1 TYPE STRING,
SVA09 TYPE STRING,
PESNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC22K_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC22K_STR-CNTR1 sy-vline
WA_PC22K_STR-BEGDA sy-vline
WA_PC22K_STR-ENDDA sy-vline
WA_PC22K_STR-JUPER sy-vline
WA_PC22K_STR-KVKZ1 sy-vline
WA_PC22K_STR-RVKZ1 sy-vline
WA_PC22K_STR-AVKZ1 sy-vline
WA_PC22K_STR-RVNUM sy-vline
WA_PC22K_STR-KVSFR sy-vline
WA_PC22K_STR-KVGST sy-vline
WA_PC22K_STR-KVBKL sy-vline
WA_PC22K_STR-KVFBT sy-vline
WA_PC22K_STR-ZUSKA sy-vline
WA_PC22K_STR-SONKV sy-vline
WA_PC22K_STR-SONRV sy-vline
WA_PC22K_STR-SONAV sy-vline
WA_PC22K_STR-SELKV sy-vline
WA_PC22K_STR-SELRV sy-vline
WA_PC22K_STR-MITNR sy-vline
WA_PC22K_STR-MAXKV sy-vline
WA_PC22K_STR-KVBAT sy-vline
WA_PC22K_STR-RVBAT sy-vline
WA_PC22K_STR-AVBAT sy-vline
WA_PC22K_STR-SVA01 sy-vline
WA_PC22K_STR-SVA02 sy-vline
WA_PC22K_STR-SVA03 sy-vline
WA_PC22K_STR-SVA04 sy-vline
WA_PC22K_STR-SVA05 sy-vline
WA_PC22K_STR-SVA06 sy-vline
WA_PC22K_STR-SVA07 sy-vline
WA_PC22K_STR-SVA08 sy-vline
WA_PC22K_STR-PVKZ1 sy-vline
WA_PC22K_STR-SVA09 sy-vline
WA_PC22K_STR-PESNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.