ABAP Select data from SAP table PC276 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC276 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC276. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC276 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC276 TYPE STANDARD TABLE OF PC276,
      WA_PC276 TYPE PC276,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC276> TYPE PC276.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC276.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC276
  INTO TABLE IT_PC276.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC276
*  INTO TABLE @DATA(IT_PC2762).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC276 INDEX 1 INTO DATA(WA_PC2762).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC276 ASSIGNING <PC276>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC276>-SEQNO = 1.
<PC276>-BEGDA = 1.
<PC276>-ENDDA = 1.
<PC276>-WERKS = 1.
<PC276>-BTRTL = 1.
ENDLOOP.

LOOP AT IT_PC276 INTO WA_PC276.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC276-NACHN, sy-vline,
WA_PC276-VORNA, sy-vline,
WA_PC276-NAMZU, sy-vline,
WA_PC276-VORSW, sy-vline,
WA_PC276-TITEL, sy-vline,
WA_PC276-STRAS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC276 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC276 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC276 INTO WA_PC276. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_PC276-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC276-GBDAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC276_STR,
SEQNO TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
NACHN TYPE STRING,
VORNA TYPE STRING,
NAMZU TYPE STRING,
VORSW TYPE STRING,
TITEL TYPE STRING,
STRAS TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
GBDAT TYPE STRING,
GBORT TYPE STRING,
RVNUM TYPE STRING,
GESCH TYPE STRING,
GBNAM TYPE STRING,
VSNUM TYPE STRING,
KTONR TYPE STRING,
VTSCH TYPE STRING,
VSBEG TYPE STRING,
TTART TYPE STRING,
BEART TYPE STRING,
SWTBE TYPE STRING,
ARBEG TYPE STRING,
AWGRD TYPE STRING,
TRWAZ TYPE STRING,
IRWAZ TYPE STRING,
ARGZU TYPE STRING,
VVZVE TYPE STRING,
BEZVE TYPE STRING,
ZWVER TYPE STRING,
ZVEID TYPE STRING,
NAMEK TYPE STRING,
NAMED TYPE STRING,
ENDVS TYPE STRING,
UAVBE TYPE STRING,
FLD01 TYPE STRING,
FLD02 TYPE STRING,
FLD03 TYPE STRING,
FLD04 TYPE STRING,
AGRND TYPE STRING,
AREND TYPE STRING,
WIEDE TYPE STRING,
LOEDA TYPE STRING,
FAMST TYPE STRING,
ANSKG TYPE STRING,
KZALT TYPE STRING,
RVPFL TYPE STRING,
STRSS TYPE STRING,
HAUSN TYPE STRING,
POSTF TYPE STRING,
LNDKZ TYPE STRING,
ARTNA TYPE STRING,
ARTAD TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC276_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC276_STR-SEQNO sy-vline
WA_PC276_STR-BEGDA sy-vline
WA_PC276_STR-ENDDA sy-vline
WA_PC276_STR-WERKS sy-vline
WA_PC276_STR-BTRTL sy-vline
WA_PC276_STR-NACHN sy-vline
WA_PC276_STR-VORNA sy-vline
WA_PC276_STR-NAMZU sy-vline
WA_PC276_STR-VORSW sy-vline
WA_PC276_STR-TITEL sy-vline
WA_PC276_STR-STRAS sy-vline
WA_PC276_STR-PSTLZ sy-vline
WA_PC276_STR-ORT01 sy-vline
WA_PC276_STR-GBDAT sy-vline
WA_PC276_STR-GBORT sy-vline
WA_PC276_STR-RVNUM sy-vline
WA_PC276_STR-GESCH sy-vline
WA_PC276_STR-GBNAM sy-vline
WA_PC276_STR-VSNUM sy-vline
WA_PC276_STR-KTONR sy-vline
WA_PC276_STR-VTSCH sy-vline
WA_PC276_STR-VSBEG sy-vline
WA_PC276_STR-TTART sy-vline
WA_PC276_STR-BEART sy-vline
WA_PC276_STR-SWTBE sy-vline
WA_PC276_STR-ARBEG sy-vline
WA_PC276_STR-AWGRD sy-vline
WA_PC276_STR-TRWAZ sy-vline
WA_PC276_STR-IRWAZ sy-vline
WA_PC276_STR-ARGZU sy-vline
WA_PC276_STR-VVZVE sy-vline
WA_PC276_STR-BEZVE sy-vline
WA_PC276_STR-ZWVER sy-vline
WA_PC276_STR-ZVEID sy-vline
WA_PC276_STR-NAMEK sy-vline
WA_PC276_STR-NAMED sy-vline
WA_PC276_STR-ENDVS sy-vline
WA_PC276_STR-UAVBE sy-vline
WA_PC276_STR-FLD01 sy-vline
WA_PC276_STR-FLD02 sy-vline
WA_PC276_STR-FLD03 sy-vline
WA_PC276_STR-FLD04 sy-vline
WA_PC276_STR-AGRND sy-vline
WA_PC276_STR-AREND sy-vline
WA_PC276_STR-WIEDE sy-vline
WA_PC276_STR-LOEDA sy-vline
WA_PC276_STR-FAMST sy-vline
WA_PC276_STR-ANSKG sy-vline
WA_PC276_STR-KZALT sy-vline
WA_PC276_STR-RVPFL sy-vline
WA_PC276_STR-STRSS sy-vline
WA_PC276_STR-HAUSN sy-vline
WA_PC276_STR-POSTF sy-vline
WA_PC276_STR-LNDKZ sy-vline
WA_PC276_STR-ARTNA sy-vline
WA_PC276_STR-ARTAD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.