ABAP Select data from SAP table PC287 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC287 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC287. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC287 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC287 TYPE STANDARD TABLE OF PC287,
      WA_PC287 TYPE PC287,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC287> TYPE PC287.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC287.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC287
  INTO TABLE IT_PC287.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC287
*  INTO TABLE @DATA(IT_PC2872).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC287 INDEX 1 INTO DATA(WA_PC2872).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC287 ASSIGNING <PC287>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC287>-PERIO = 1.
<PC287>-CAFRD = 1.
<PC287>-CAFRN = 1.
<PC287>-LGART = 1.
<PC287>-ZFPER = 1.
ENDLOOP.

LOOP AT IT_PC287 INTO WA_PC287.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC287-ZDATE, sy-vline,
WA_PC287-WAERS, sy-vline,
WA_PC287-BETRG, sy-vline,
WA_PC287-REFNR, sy-vline,
WA_PC287-PENFN, sy-vline,
WA_PC287-ORADV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC287 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC287 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC287 INTO WA_PC287. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC287_STR,
PERIO TYPE STRING,
CAFRD TYPE STRING,
CAFRN TYPE STRING,
LGART TYPE STRING,
ZFPER TYPE STRING,
ZDATE TYPE STRING,
WAERS TYPE STRING,
BETRG TYPE STRING,
REFNR TYPE STRING,
PENFN TYPE STRING,
ORADV TYPE STRING,
COZIV TYPE STRING,
KINPE TYPE STRING,
JURST TYPE STRING,
KINCA TYPE STRING,
BETRT TYPE STRING,
BETPT TYPE STRING,
ANZHT TYPE STRING,
BETRS TYPE STRING,
BETPS TYPE STRING,
ANZHS TYPE STRING,
SIGN1 TYPE STRING,
BETRO TYPE STRING,
BETPO TYPE STRING,
ANZHO TYPE STRING,
SIGN2 TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
OBJPS TYPE STRING,
COADV TYPE STRING,
INSTN TYPE STRING,
ENDVA TYPE STRING,
CANCL TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC287_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC287_STR-PERIO sy-vline
WA_PC287_STR-CAFRD sy-vline
WA_PC287_STR-CAFRN sy-vline
WA_PC287_STR-LGART sy-vline
WA_PC287_STR-ZFPER sy-vline
WA_PC287_STR-ZDATE sy-vline
WA_PC287_STR-WAERS sy-vline
WA_PC287_STR-BETRG sy-vline
WA_PC287_STR-REFNR sy-vline
WA_PC287_STR-PENFN sy-vline
WA_PC287_STR-ORADV sy-vline
WA_PC287_STR-COZIV sy-vline
WA_PC287_STR-KINPE sy-vline
WA_PC287_STR-JURST sy-vline
WA_PC287_STR-KINCA sy-vline
WA_PC287_STR-BETRT sy-vline
WA_PC287_STR-BETPT sy-vline
WA_PC287_STR-ANZHT sy-vline
WA_PC287_STR-BETRS sy-vline
WA_PC287_STR-BETPS sy-vline
WA_PC287_STR-ANZHS sy-vline
WA_PC287_STR-SIGN1 sy-vline
WA_PC287_STR-BETRO sy-vline
WA_PC287_STR-BETPO sy-vline
WA_PC287_STR-ANZHO sy-vline
WA_PC287_STR-SIGN2 sy-vline
WA_PC287_STR-BEGDA sy-vline
WA_PC287_STR-ENDDA sy-vline
WA_PC287_STR-OBJPS sy-vline
WA_PC287_STR-COADV sy-vline
WA_PC287_STR-INSTN sy-vline
WA_PC287_STR-ENDVA sy-vline
WA_PC287_STR-CANCL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.