ABAP Select data from SAP table PC2E0 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2E0 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2E0. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PC2E0 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PC2E0 TYPE STANDARD TABLE OF PC2E0, WA_PC2E0 TYPE PC2E0, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PC2E0> TYPE PC2E0. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PC2E0. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PC2E0 INTO TABLE IT_PC2E0. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PC2E0 * INTO TABLE @DATA(IT_PC2E02). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PC2E0 INDEX 1 INTO DATA(WA_PC2E02). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PC2E0 ASSIGNING <PC2E0>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2E0>-IONUM = 1.
<PC2E0>-JURIS = 1.
<PC2E0>-GCATE = 1.
<PC2E0>-IOPRI = 1.
<PC2E0>-GFCOD = 1.
ENDLOOP. LOOP AT IT_PC2E0 INTO WA_PC2E0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PC2E0-ORDDA, sy-vline,
WA_PC2E0-PAYTY, sy-vline,
WA_PC2E0-PERMO, sy-vline,
WA_PC2E0-PABRD, sy-vline,
WA_PC2E0-LABRD, sy-vline,
WA_PC2E0-PABRP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2E0 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2E0 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2E0 INTO WA_PC2E0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field PABRJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PC2E0-PABRJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2E0-PABRJ.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field CYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PC2E0-CYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2E0-CYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PC2E0-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2E0-LIFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2E0_STR,
IONUM TYPE STRING,
JURIS TYPE STRING,
GCATE TYPE STRING,
IOPRI TYPE STRING,
GFCOD TYPE STRING,
ORDDA TYPE STRING,
PAYTY TYPE STRING,
PERMO TYPE STRING,
PABRD TYPE STRING,
LABRD TYPE STRING,
PABRP TYPE STRING,
PABRJ TYPE STRING,
ZEINH TYPE STRING,
CMONT TYPE STRING,
CYEAR TYPE STRING,
BABRP TYPE STRING,
EABRP TYPE STRING,
NPPYA TYPE STRING,
DATMO TYPE STRING,
CRETY TYPE STRING,
CRENR TYPE STRING,
LIFNR TYPE STRING,
LIFSG TYPE STRING,
RULNR TYPE STRING,
IOSCI TYPE STRING,
IOSRT TYPE STRING,
IOSTS TYPE STRING,
EMFTX TYPE STRING,
BANKN TYPE STRING,
ZLSCH TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2E0_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2E0_STR-IONUM sy-vline
WA_PC2E0_STR-JURIS sy-vline
WA_PC2E0_STR-GCATE sy-vline
WA_PC2E0_STR-IOPRI sy-vline
WA_PC2E0_STR-GFCOD sy-vline
WA_PC2E0_STR-ORDDA sy-vline
WA_PC2E0_STR-PAYTY sy-vline
WA_PC2E0_STR-PERMO sy-vline
WA_PC2E0_STR-PABRD sy-vline
WA_PC2E0_STR-LABRD sy-vline
WA_PC2E0_STR-PABRP sy-vline
WA_PC2E0_STR-PABRJ sy-vline
WA_PC2E0_STR-ZEINH sy-vline
WA_PC2E0_STR-CMONT sy-vline
WA_PC2E0_STR-CYEAR sy-vline
WA_PC2E0_STR-BABRP sy-vline
WA_PC2E0_STR-EABRP sy-vline
WA_PC2E0_STR-NPPYA sy-vline
WA_PC2E0_STR-DATMO sy-vline
WA_PC2E0_STR-CRETY sy-vline
WA_PC2E0_STR-CRENR sy-vline
WA_PC2E0_STR-LIFNR sy-vline
WA_PC2E0_STR-LIFSG sy-vline
WA_PC2E0_STR-RULNR sy-vline
WA_PC2E0_STR-IOSCI sy-vline
WA_PC2E0_STR-IOSRT sy-vline
WA_PC2E0_STR-IOSTS sy-vline
WA_PC2E0_STR-EMFTX sy-vline
WA_PC2E0_STR-BANKN sy-vline
WA_PC2E0_STR-ZLSCH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.