ABAP Select data from SAP table PC2G2 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2G2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2G2. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PC2G2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PC2G2 TYPE STANDARD TABLE OF PC2G2, WA_PC2G2 TYPE PC2G2, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PC2G2> TYPE PC2G2. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PC2G2. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PC2G2 INTO TABLE IT_PC2G2. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PC2G2 * INTO TABLE @DATA(IT_PC2G22). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PC2G2 INDEX 1 INTO DATA(WA_PC2G22). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PC2G2 ASSIGNING <PC2G2>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2G2>-BEGDA = 1.
<PC2G2>-ENDDA = 1.
<PC2G2>-INNUM = 1.
<PC2G2>-CONAR = 1.
<PC2G2>-CONTY = 1.
ENDLOOP. LOOP AT IT_PC2G2 INTO WA_PC2G2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PC2G2-CONGR, sy-vline,
WA_PC2G2-CONLV, sy-vline,
WA_PC2G2-PBYER, sy-vline,
WA_PC2G2-EEIND, sy-vline,
WA_PC2G2-EERAT, sy-vline,
WA_PC2G2-EECON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2G2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2G2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2G2 INTO WA_PC2G2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2G2_STR,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
INNUM TYPE STRING,
CONAR TYPE STRING,
CONTY TYPE STRING,
CONGR TYPE STRING,
CONLV TYPE STRING,
PBYER TYPE STRING,
EEIND TYPE STRING,
EERAT TYPE STRING,
EECON TYPE STRING,
ECCUR TYPE STRING,
EELOW TYPE STRING,
EELCU TYPE STRING,
EEHIG TYPE STRING,
EEHCU TYPE STRING,
ERIND TYPE STRING,
ERRAT TYPE STRING,
ERCON TYPE STRING,
RCCUR TYPE STRING,
ERLOW TYPE STRING,
ERLCU TYPE STRING,
ERHIG TYPE STRING,
ERHCU TYPE STRING,
MOCON TYPE STRING,
PITAX TYPE STRING,
PASSR TYPE STRING,
EEBSR TYPE STRING,
EECOR TYPE STRING,
EEWGE TYPE STRING,
ERBSR TYPE STRING,
ERCOR TYPE STRING,
ERWGE TYPE STRING,
ERDIF TYPE STRING,
EMRAT TYPE STRING,
EMMTP TYPE STRING,
EMAVG TYPE STRING,
EXMTH TYPE STRING,
EERAT3 TYPE STRING,
ERRAT3 TYPE STRING,
EEEMP TYPE STRING,
EEECU TYPE STRING,
EREMP TYPE STRING,
ERECU TYPE STRING,
MOSAS TYPE STRING,
EXMPT_RATE_EE TYPE STRING,
EXMPT_RATE_ER TYPE STRING,
DIFF_EXMPT_EE_ER TYPE STRING,
EXBSR TYPE STRING,
EXCOR TYPE STRING,
EMPFG TYPE STRING,
EMPAR TYPE STRING,
EMPBR TYPE STRING,
EMPGR TYPE STRING,
EMPLV TYPE STRING,
EERT4 TYPE STRING,
ERRT4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2G2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2G2_STR-BEGDA sy-vline
WA_PC2G2_STR-ENDDA sy-vline
WA_PC2G2_STR-INNUM sy-vline
WA_PC2G2_STR-CONAR sy-vline
WA_PC2G2_STR-CONTY sy-vline
WA_PC2G2_STR-CONGR sy-vline
WA_PC2G2_STR-CONLV sy-vline
WA_PC2G2_STR-PBYER sy-vline
WA_PC2G2_STR-EEIND sy-vline
WA_PC2G2_STR-EERAT sy-vline
WA_PC2G2_STR-EECON sy-vline
WA_PC2G2_STR-ECCUR sy-vline
WA_PC2G2_STR-EELOW sy-vline
WA_PC2G2_STR-EELCU sy-vline
WA_PC2G2_STR-EEHIG sy-vline
WA_PC2G2_STR-EEHCU sy-vline
WA_PC2G2_STR-ERIND sy-vline
WA_PC2G2_STR-ERRAT sy-vline
WA_PC2G2_STR-ERCON sy-vline
WA_PC2G2_STR-RCCUR sy-vline
WA_PC2G2_STR-ERLOW sy-vline
WA_PC2G2_STR-ERLCU sy-vline
WA_PC2G2_STR-ERHIG sy-vline
WA_PC2G2_STR-ERHCU sy-vline
WA_PC2G2_STR-MOCON sy-vline
WA_PC2G2_STR-PITAX sy-vline
WA_PC2G2_STR-PASSR sy-vline
WA_PC2G2_STR-EEBSR sy-vline
WA_PC2G2_STR-EECOR sy-vline
WA_PC2G2_STR-EEWGE sy-vline
WA_PC2G2_STR-ERBSR sy-vline
WA_PC2G2_STR-ERCOR sy-vline
WA_PC2G2_STR-ERWGE sy-vline
WA_PC2G2_STR-ERDIF sy-vline
WA_PC2G2_STR-EMRAT sy-vline
WA_PC2G2_STR-EMMTP sy-vline
WA_PC2G2_STR-EMAVG sy-vline
WA_PC2G2_STR-EXMTH sy-vline
WA_PC2G2_STR-EERAT3 sy-vline
WA_PC2G2_STR-ERRAT3 sy-vline
WA_PC2G2_STR-EEEMP sy-vline
WA_PC2G2_STR-EEECU sy-vline
WA_PC2G2_STR-EREMP sy-vline
WA_PC2G2_STR-ERECU sy-vline
WA_PC2G2_STR-MOSAS sy-vline
WA_PC2G2_STR-EXMPT_RATE_EE sy-vline
WA_PC2G2_STR-EXMPT_RATE_ER sy-vline
WA_PC2G2_STR-DIFF_EXMPT_EE_ER sy-vline
WA_PC2G2_STR-EXBSR sy-vline
WA_PC2G2_STR-EXCOR sy-vline
WA_PC2G2_STR-EMPFG sy-vline
WA_PC2G2_STR-EMPAR sy-vline
WA_PC2G2_STR-EMPBR sy-vline
WA_PC2G2_STR-EMPGR sy-vline
WA_PC2G2_STR-EMPLV sy-vline
WA_PC2G2_STR-EERT4 sy-vline
WA_PC2G2_STR-ERRT4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.