ABAP Select data from SAP table PCH_ASM_TITLEBAR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PCH_ASM_TITLEBAR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PCH_ASM_TITLEBAR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PCH_ASM_TITLEBAR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PCH_ASM_TITLEBAR TYPE STANDARD TABLE OF PCH_ASM_TITLEBAR, WA_PCH_ASM_TITLEBAR TYPE PCH_ASM_TITLEBAR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PCH_ASM_TITLEBAR> TYPE PCH_ASM_TITLEBAR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PCH_ASM_TITLEBAR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PCH_ASM_TITLEBAR INTO TABLE IT_PCH_ASM_TITLEBAR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PCH_ASM_TITLEBAR * INTO TABLE @DATA(IT_PCH_ASM_TITLEBAR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PCH_ASM_TITLEBAR INDEX 1 INTO DATA(WA_PCH_ASM_TITLEBAR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PCH_ASM_TITLEBAR ASSIGNING <PCH_ASM_TITLEBAR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PCH_ASM_TITLEBAR>-FIRMATXT = 1.
<PCH_ASM_TITLEBAR>-TITLESTRING = 1.
<PCH_ASM_TITLEBAR>-TXT002 = 1.
<PCH_ASM_TITLEBAR>-PGNO = 1.
<PCH_ASM_TITLEBAR>-ASMCODE = 1.
ENDLOOP. LOOP AT IT_PCH_ASM_TITLEBAR INTO WA_PCH_ASM_TITLEBAR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PCH_ASM_TITLEBAR-LOCDATE, sy-vline,
WA_PCH_ASM_TITLEBAR-HBTXT1, sy-vline,
WA_PCH_ASM_TITLEBAR-GESCHTXT, sy-vline,
WA_PCH_ASM_TITLEBAR-LOCTIME, sy-vline,
WA_PCH_ASM_TITLEBAR-HBTXT2, sy-vline,
WA_PCH_ASM_TITLEBAR-LN5COL01, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PCH_ASM_TITLEBAR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PCH_ASM_TITLEBAR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PCH_ASM_TITLEBAR INTO WA_PCH_ASM_TITLEBAR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ASMCD, internal->external for field ASMCODE CALL FUNCTION 'CONVERSION_EXIT_ASMCD_OUTPUT' EXPORTING input = WA_PCH_ASM_TITLEBAR-ASMCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PCH_ASM_TITLEBAR-ASMCODE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PCH_ASM_TITLEBAR_STR,
FIRMATXT TYPE STRING,
TITLESTRING TYPE STRING,
TXT002 TYPE STRING,
PGNO TYPE STRING,
ASMCODE TYPE STRING,
LOCDATE TYPE STRING,
HBTXT1 TYPE STRING,
GESCHTXT TYPE STRING,
LOCTIME TYPE STRING,
HBTXT2 TYPE STRING,
LN5COL01 TYPE STRING,
LN5COL02 TYPE STRING,
LN5COL03 TYPE STRING,
LN5COL04 TYPE STRING,
LN5COL05 TYPE STRING,
LN6COL01 TYPE STRING,
LN6COL02 TYPE STRING,
LN6COL03 TYPE STRING,
LN6COL04 TYPE STRING,
LN6COL05 TYPE STRING,
LN6COL06 TYPE STRING,
LN6COL07 TYPE STRING,
LN6COL08 TYPE STRING,
LN6COL09 TYPE STRING,
LN6COL10 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PCH_ASM_TITLEBAR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PCH_ASM_TITLEBAR_STR-FIRMATXT sy-vline
WA_PCH_ASM_TITLEBAR_STR-TITLESTRING sy-vline
WA_PCH_ASM_TITLEBAR_STR-TXT002 sy-vline
WA_PCH_ASM_TITLEBAR_STR-PGNO sy-vline
WA_PCH_ASM_TITLEBAR_STR-ASMCODE sy-vline
WA_PCH_ASM_TITLEBAR_STR-LOCDATE sy-vline
WA_PCH_ASM_TITLEBAR_STR-HBTXT1 sy-vline
WA_PCH_ASM_TITLEBAR_STR-GESCHTXT sy-vline
WA_PCH_ASM_TITLEBAR_STR-LOCTIME sy-vline
WA_PCH_ASM_TITLEBAR_STR-HBTXT2 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN5COL01 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN5COL02 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN5COL03 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN5COL04 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN5COL05 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL01 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL02 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL03 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL04 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL05 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL06 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL07 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL08 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL09 sy-vline
WA_PCH_ASM_TITLEBAR_STR-LN6COL10 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.