ABAP Select data from SAP table PDT_S_LEANWM_HU into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PDT_S_LEANWM_HU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PDT_S_LEANWM_HU. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PDT_S_LEANWM_HU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PDT_S_LEANWM_HU TYPE STANDARD TABLE OF PDT_S_LEANWM_HU, WA_PDT_S_LEANWM_HU TYPE PDT_S_LEANWM_HU, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PDT_S_LEANWM_HU> TYPE PDT_S_LEANWM_HU. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PDT_S_LEANWM_HU. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PDT_S_LEANWM_HU INTO TABLE IT_PDT_S_LEANWM_HU. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PDT_S_LEANWM_HU * INTO TABLE @DATA(IT_PDT_S_LEANWM_HU2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PDT_S_LEANWM_HU INDEX 1 INTO DATA(WA_PDT_S_LEANWM_HU2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PDT_S_LEANWM_HU ASSIGNING <PDT_S_LEANWM_HU>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PDT_S_LEANWM_HU>-TOP_HU_EXTERNAL = 1.
<PDT_S_LEANWM_HU>-TOP_HU_INTERNAL = 1.
<PDT_S_LEANWM_HU>-MATNR = 1.
<PDT_S_LEANWM_HU>-CHARG = 1.
<PDT_S_LEANWM_HU>-VEMNG = 1.
ENDLOOP. LOOP AT IT_PDT_S_LEANWM_HU INTO WA_PDT_S_LEANWM_HU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PDT_S_LEANWM_HU-VEMEH, sy-vline,
ENDLOOP. *Add any further fields from structure WA_PDT_S_LEANWM_HU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PDT_S_LEANWM_HU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PDT_S_LEANWM_HU INTO WA_PDT_S_LEANWM_HU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field TOP_HU_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PDT_S_LEANWM_HU-TOP_HU_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDT_S_LEANWM_HU-TOP_HU_EXTERNAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TOP_HU_INTERNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PDT_S_LEANWM_HU-TOP_HU_INTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDT_S_LEANWM_HU-TOP_HU_INTERNAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PDT_S_LEANWM_HU-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDT_S_LEANWM_HU-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VEMEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PDT_S_LEANWM_HU-VEMEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDT_S_LEANWM_HU-VEMEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PDT_S_LEANWM_HU_STR,
TOP_HU_EXTERNAL TYPE STRING,
TOP_HU_INTERNAL TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
VEMNG TYPE STRING,
VEMEH TYPE STRING,END OF T_EKKO_STR. DATA: WA_PDT_S_LEANWM_HU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PDT_S_LEANWM_HU_STR-TOP_HU_EXTERNAL sy-vline
WA_PDT_S_LEANWM_HU_STR-TOP_HU_INTERNAL sy-vline
WA_PDT_S_LEANWM_HU_STR-MATNR sy-vline
WA_PDT_S_LEANWM_HU_STR-CHARG sy-vline
WA_PDT_S_LEANWM_HU_STR-VEMNG sy-vline
WA_PDT_S_LEANWM_HU_STR-VEMEH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.