ABAP Select data from SAP table PFIRTPCORITFPT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PFIRTPCORITFPT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PFIRTPCORITFPT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PFIRTPCORITFPT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PFIRTPCORITFPT TYPE STANDARD TABLE OF PFIRTPCORITFPT, WA_PFIRTPCORITFPT TYPE PFIRTPCORITFPT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PFIRTPCORITFPT> TYPE PFIRTPCORITFPT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PFIRTPCORITFPT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PFIRTPCORITFPT INTO TABLE IT_PFIRTPCORITFPT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PFIRTPCORITFPT * INTO TABLE @DATA(IT_PFIRTPCORITFPT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PFIRTPCORITFPT INDEX 1 INTO DATA(WA_PFIRTPCORITFPT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PFIRTPCORITFPT ASSIGNING <PFIRTPCORITFPT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PFIRTPCORITFPT>-MANDT = 1.
<PFIRTPCORITFPT>-CONTROLLINGOBJECT = 1.
<PFIRTPCORITFPT>-ORDERID = 1.
<PFIRTPCORITFPT>-ORDERITEM = 1.
<PFIRTPCORITFPT>-LEDGER = 1.
ENDLOOP. LOOP AT IT_PFIRTPCORITFPT INTO WA_PFIRTPCORITFPT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PFIRTPCORITFPT-FISCALYEARPERIOD, sy-vline,
WA_PFIRTPCORITFPT-UNITOFMEASURE, sy-vline,
WA_PFIRTPCORITFPT-ENTRYUNITOFMEASURE, sy-vline,
WA_PFIRTPCORITFPT-HSL, sy-vline,
WA_PFIRTPCORITFPT-KSL, sy-vline,
WA_PFIRTPCORITFPT-OSL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PFIRTPCORITFPT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PFIRTPCORITFPT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PFIRTPCORITFPT INTO WA_PFIRTPCORITFPT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field ORDERID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFIRTPCORITFPT-ORDERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFIRTPCORITFPT-ORDERID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LEDGER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFIRTPCORITFPT-LEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFIRTPCORITFPT-LEDGER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PERI7, internal->external for field FISCALYEARPERIOD CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_PFIRTPCORITFPT-FISCALYEARPERIOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFIRTPCORITFPT-FISCALYEARPERIOD.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNITOFMEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PFIRTPCORITFPT-UNITOFMEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFIRTPCORITFPT-UNITOFMEASURE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ENTRYUNITOFMEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PFIRTPCORITFPT-ENTRYUNITOFMEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFIRTPCORITFPT-ENTRYUNITOFMEASURE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PFIRTPCORITFPT_STR,
MANDT TYPE STRING,
CONTROLLINGOBJECT TYPE STRING,
ORDERID TYPE STRING,
ORDERITEM TYPE STRING,
LEDGER TYPE STRING,
FISCALYEARPERIOD TYPE STRING,
UNITOFMEASURE TYPE STRING,
ENTRYUNITOFMEASURE TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
OSL TYPE STRING,
VSL TYPE STRING,
BSL TYPE STRING,
CSL TYPE STRING,
DSL TYPE STRING,
ESL TYPE STRING,
FSL TYPE STRING,
GSL TYPE STRING,
KFSL TYPE STRING,
VMSL TYPE STRING,
MSL TYPE STRING,END OF T_EKKO_STR. DATA: WA_PFIRTPCORITFPT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PFIRTPCORITFPT_STR-MANDT sy-vline
WA_PFIRTPCORITFPT_STR-CONTROLLINGOBJECT sy-vline
WA_PFIRTPCORITFPT_STR-ORDERID sy-vline
WA_PFIRTPCORITFPT_STR-ORDERITEM sy-vline
WA_PFIRTPCORITFPT_STR-LEDGER sy-vline
WA_PFIRTPCORITFPT_STR-FISCALYEARPERIOD sy-vline
WA_PFIRTPCORITFPT_STR-UNITOFMEASURE sy-vline
WA_PFIRTPCORITFPT_STR-ENTRYUNITOFMEASURE sy-vline
WA_PFIRTPCORITFPT_STR-HSL sy-vline
WA_PFIRTPCORITFPT_STR-KSL sy-vline
WA_PFIRTPCORITFPT_STR-OSL sy-vline
WA_PFIRTPCORITFPT_STR-VSL sy-vline
WA_PFIRTPCORITFPT_STR-BSL sy-vline
WA_PFIRTPCORITFPT_STR-CSL sy-vline
WA_PFIRTPCORITFPT_STR-DSL sy-vline
WA_PFIRTPCORITFPT_STR-ESL sy-vline
WA_PFIRTPCORITFPT_STR-FSL sy-vline
WA_PFIRTPCORITFPT_STR-GSL sy-vline
WA_PFIRTPCORITFPT_STR-KFSL sy-vline
WA_PFIRTPCORITFPT_STR-VMSL sy-vline
WA_PFIRTPCORITFPT_STR-MSL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.