ABAP Select data from SAP table PFR_RPLACIF0_FORM_STR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PFR_RPLACIF0_FORM_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PFR_RPLACIF0_FORM_STR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PFR_RPLACIF0_FORM_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PFR_RPLACIF0_FORM_STR TYPE STANDARD TABLE OF PFR_RPLACIF0_FORM_STR, WA_PFR_RPLACIF0_FORM_STR TYPE PFR_RPLACIF0_FORM_STR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PFR_RPLACIF0_FORM_STR> TYPE PFR_RPLACIF0_FORM_STR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PFR_RPLACIF0_FORM_STR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PFR_RPLACIF0_FORM_STR INTO TABLE IT_PFR_RPLACIF0_FORM_STR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PFR_RPLACIF0_FORM_STR * INTO TABLE @DATA(IT_PFR_RPLACIF0_FORM_STR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PFR_RPLACIF0_FORM_STR INDEX 1 INTO DATA(WA_PFR_RPLACIF0_FORM_STR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PFR_RPLACIF0_FORM_STR ASSIGNING <PFR_RPLACIF0_FORM_STR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PFR_RPLACIF0_FORM_STR>-BEGDA = 1.
<PFR_RPLACIF0_FORM_STR>-C_CONG = 1.
<PFR_RPLACIF0_FORM_STR>-CLECON = 1.
<PFR_RPLACIF0_FORM_STR>-CLE_ENT = 1.
<PFR_RPLACIF0_FORM_STR>-EMPLOI = 1.
ENDLOOP. LOOP AT IT_PFR_RPLACIF0_FORM_STR INTO WA_PFR_RPLACIF0_FORM_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PFR_RPLACIF0_FORM_STR-ENDDA, sy-vline,
WA_PFR_RPLACIF0_FORM_STR-J_CACH, sy-vline,
WA_PFR_RPLACIF0_FORM_STR-NACHN, sy-vline,
WA_PFR_RPLACIF0_FORM_STR-NAME2, sy-vline,
WA_PFR_RPLACIF0_FORM_STR-NUM_CERTIF, sy-vline,
WA_PFR_RPLACIF0_FORM_STR-NUMCON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PFR_RPLACIF0_FORM_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PFR_RPLACIF0_FORM_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PFR_RPLACIF0_FORM_STR INTO WA_PFR_RPLACIF0_FORM_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PFR_RPLACIF0_FORM_STR_STR,
BEGDA TYPE STRING,
C_CONG TYPE STRING,
CLECON TYPE STRING,
CLE_ENT TYPE STRING,
EMPLOI TYPE STRING,
ENDDA TYPE STRING,
J_CACH TYPE STRING,
NACHN TYPE STRING,
NAME2 TYPE STRING,
NUM_CERTIF TYPE STRING,
NUMCON TYPE STRING,
NUM_ENT TYPE STRING,
SOCIAL TYPE STRING,
PAIEMENT TYPE STRING,
RUFNM TYPE STRING,
S_BRUT TYPE STRING,
VORNA TYPE STRING,
WAERS TYPE STRING,
CADRE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PFR_RPLACIF0_FORM_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-BEGDA sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-C_CONG sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-CLECON sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-CLE_ENT sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-EMPLOI sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-ENDDA sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-J_CACH sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-NACHN sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-NAME2 sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-NUM_CERTIF sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-NUMCON sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-NUM_ENT sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-SOCIAL sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-PAIEMENT sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-RUFNM sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-S_BRUT sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-VORNA sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-WAERS sy-vline
WA_PFR_RPLACIF0_FORM_STR_STR-CADRE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.