ABAP Select data from SAP table PIN_EACHST_TASKS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIN_EACHST_TASKS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIN_EACHST_TASKS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIN_EACHST_TASKS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIN_EACHST_TASKS TYPE STANDARD TABLE OF PIN_EACHST_TASKS,
      WA_PIN_EACHST_TASKS TYPE PIN_EACHST_TASKS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIN_EACHST_TASKS> TYPE PIN_EACHST_TASKS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIN_EACHST_TASKS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIN_EACHST_TASKS
  INTO TABLE IT_PIN_EACHST_TASKS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIN_EACHST_TASKS
*  INTO TABLE @DATA(IT_PIN_EACHST_TASKS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIN_EACHST_TASKS INDEX 1 INTO DATA(WA_PIN_EACHST_TASKS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIN_EACHST_TASKS ASSIGNING <PIN_EACHST_TASKS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIN_EACHST_TASKS>-X_DAT01 = 1.
<PIN_EACHST_TASKS>-X_DAT02 = 1.
<PIN_EACHST_TASKS>-X_DAT03 = 1.
<PIN_EACHST_TASKS>-X_DAT04 = 1.
<PIN_EACHST_TASKS>-X_DAT05 = 1.
ENDLOOP.

LOOP AT IT_PIN_EACHST_TASKS INTO WA_PIN_EACHST_TASKS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIN_EACHST_TASKS-X_CBX01, sy-vline,
WA_PIN_EACHST_TASKS-X_CBX02, sy-vline,
WA_PIN_EACHST_TASKS-X_CBX03, sy-vline,
WA_PIN_EACHST_TASKS-X_CBX04, sy-vline,
WA_PIN_EACHST_TASKS-X_CBX05, sy-vline,
WA_PIN_EACHST_TASKS-X_AMT01, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIN_EACHST_TASKS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIN_EACHST_TASKS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIN_EACHST_TASKS INTO WA_PIN_EACHST_TASKS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field X_UNT01 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIN_EACHST_TASKS-X_UNT01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIN_EACHST_TASKS-X_UNT01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field X_UNT02 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIN_EACHST_TASKS-X_UNT02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIN_EACHST_TASKS-X_UNT02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field X_UNT03 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIN_EACHST_TASKS-X_UNT03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIN_EACHST_TASKS-X_UNT03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field X_UNT04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIN_EACHST_TASKS-X_UNT04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIN_EACHST_TASKS-X_UNT04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field X_UNT05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIN_EACHST_TASKS-X_UNT05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIN_EACHST_TASKS-X_UNT05.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIN_EACHST_TASKS_STR,
X_DAT01 TYPE STRING,
X_DAT02 TYPE STRING,
X_DAT03 TYPE STRING,
X_DAT04 TYPE STRING,
X_DAT05 TYPE STRING,
X_CBX01 TYPE STRING,
X_CBX02 TYPE STRING,
X_CBX03 TYPE STRING,
X_CBX04 TYPE STRING,
X_CBX05 TYPE STRING,
X_AMT01 TYPE STRING,
X_AMT02 TYPE STRING,
X_AMT03 TYPE STRING,
X_AMT04 TYPE STRING,
X_AMT05 TYPE STRING,
X_WEA01 TYPE STRING,
X_WEA02 TYPE STRING,
X_WEA03 TYPE STRING,
X_WEA04 TYPE STRING,
X_WEA05 TYPE STRING,
X_QTY01 TYPE STRING,
X_QTY02 TYPE STRING,
X_QTY03 TYPE STRING,
X_QTY04 TYPE STRING,
X_QTY05 TYPE STRING,
X_UNT01 TYPE STRING,
X_UNT02 TYPE STRING,
X_UNT03 TYPE STRING,
X_UNT04 TYPE STRING,
X_UNT05 TYPE STRING,
X_DEC01 TYPE STRING,
X_DEC02 TYPE STRING,
X_DEC03 TYPE STRING,
X_DEC04 TYPE STRING,
X_DEC05 TYPE STRING,
X_C01F0 TYPE STRING,
X_C01F1 TYPE STRING,
X_C01F2 TYPE STRING,
X_C01F3 TYPE STRING,
X_C01F4 TYPE STRING,
X_C02F0 TYPE STRING,
X_C02F1 TYPE STRING,
X_C02F2 TYPE STRING,
X_C02F3 TYPE STRING,
X_C02F4 TYPE STRING,
X_C04F0 TYPE STRING,
X_C04F1 TYPE STRING,
X_C04F2 TYPE STRING,
X_C04F3 TYPE STRING,
X_C04F4 TYPE STRING,
X_C10F0 TYPE STRING,
X_C10F1 TYPE STRING,
X_C10F2 TYPE STRING,
X_C10F3 TYPE STRING,
X_C10F4 TYPE STRING,
X_C20F0 TYPE STRING,
X_C20F1 TYPE STRING,
X_C20F2 TYPE STRING,
X_C20F3 TYPE STRING,
X_C20F4 TYPE STRING,
X_N03F0 TYPE STRING,
X_N03F1 TYPE STRING,
X_N03F2 TYPE STRING,
X_N03F3 TYPE STRING,
X_N03F4 TYPE STRING,
X_N05F0 TYPE STRING,
X_N05F1 TYPE STRING,
X_N05F2 TYPE STRING,
X_N05F3 TYPE STRING,
X_N05F4 TYPE STRING,
X_N10F0 TYPE STRING,
X_N10F1 TYPE STRING,
X_N10F2 TYPE STRING,
X_N10F3 TYPE STRING,
X_N10F4 TYPE STRING,
X_N16F0 TYPE STRING,
X_N16F1 TYPE STRING,
X_N16F2 TYPE STRING,
X_N16F3 TYPE STRING,
X_N16F4 TYPE STRING,
X_N20F0 TYPE STRING,
X_N20F1 TYPE STRING,
X_N20F2 TYPE STRING,
X_N20F3 TYPE STRING,
X_N20F4 TYPE STRING,
X_T50F0 TYPE STRING,
X_T50F1 TYPE STRING,
X_T50F2 TYPE STRING,
X_T50F3 TYPE STRING,
X_T50F4 TYPE STRING,
X_T80F0 TYPE STRING,
X_T80F1 TYPE STRING,
X_T80F2 TYPE STRING,
X_T80F3 TYPE STRING,
X_T80F4 TYPE STRING,
X_T4096F0 TYPE STRING,
X_T4096F1 TYPE STRING,
X_T4096F2 TYPE STRING,
X_T4096F3 TYPE STRING,
X_T4096F4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIN_EACHST_TASKS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIN_EACHST_TASKS_STR-X_DAT01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DAT02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DAT03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DAT04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DAT05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_CBX01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_CBX02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_CBX03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_CBX04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_CBX05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_AMT01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_AMT02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_AMT03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_AMT04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_AMT05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_WEA01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_WEA02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_WEA03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_WEA04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_WEA05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_QTY01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_QTY02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_QTY03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_QTY04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_QTY05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_UNT01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_UNT02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_UNT03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_UNT04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_UNT05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DEC01 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DEC02 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DEC03 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DEC04 sy-vline
WA_PIN_EACHST_TASKS_STR-X_DEC05 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C01F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C01F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C01F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C01F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C01F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C02F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C02F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C02F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C02F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C02F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C04F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C04F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C04F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C04F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C04F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C10F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C10F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C10F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C10F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C10F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C20F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C20F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C20F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C20F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_C20F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N03F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N03F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N03F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N03F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N03F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N05F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N05F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N05F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N05F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N05F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N10F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N10F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N10F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N10F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N10F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N16F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N16F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N16F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N16F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N16F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N20F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N20F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N20F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N20F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_N20F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T50F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T50F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T50F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T50F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T50F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T80F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T80F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T80F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T80F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T80F4 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T4096F0 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T4096F1 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T4096F2 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T4096F3 sy-vline
WA_PIN_EACHST_TASKS_STR-X_T4096F4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.