ABAP Select data from SAP table PIN_SS_IFOS_HP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIN_SS_IFOS_HP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIN_SS_IFOS_HP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PIN_SS_IFOS_HP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PIN_SS_IFOS_HP TYPE STANDARD TABLE OF PIN_SS_IFOS_HP, WA_PIN_SS_IFOS_HP TYPE PIN_SS_IFOS_HP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PIN_SS_IFOS_HP> TYPE PIN_SS_IFOS_HP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PIN_SS_IFOS_HP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PIN_SS_IFOS_HP INTO TABLE IT_PIN_SS_IFOS_HP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PIN_SS_IFOS_HP * INTO TABLE @DATA(IT_PIN_SS_IFOS_HP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PIN_SS_IFOS_HP INDEX 1 INTO DATA(WA_PIN_SS_IFOS_HP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PIN_SS_IFOS_HP ASSIGNING <PIN_SS_IFOS_HP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIN_SS_IFOS_HP>-PRPNO = 1.
<PIN_SS_IFOS_HP>-RDVAL = 1.
<PIN_SS_IFOS_HP>-ENVAL = 1.
<PIN_SS_IFOS_HP>-RENTO = 1.
<PIN_SS_IFOS_HP>-LETVL = 1.
ENDLOOP. LOOP AT IT_PIN_SS_IFOS_HP INTO WA_PIN_SS_IFOS_HP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PIN_SS_IFOS_HP-SEC23, sy-vline,
WA_PIN_SS_IFOS_HP-INT24, sy-vline,
WA_PIN_SS_IFOS_HP-REP24, sy-vline,
WA_PIN_SS_IFOS_HP-OTH24, sy-vline,
WA_PIN_SS_IFOS_HP-BSPFT, sy-vline,
WA_PIN_SS_IFOS_HP-CPGLN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIN_SS_IFOS_HP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIN_SS_IFOS_HP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIN_SS_IFOS_HP INTO WA_PIN_SS_IFOS_HP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIN_SS_IFOS_HP_STR,
PRPNO TYPE STRING,
RDVAL TYPE STRING,
ENVAL TYPE STRING,
RENTO TYPE STRING,
LETVL TYPE STRING,
SEC23 TYPE STRING,
INT24 TYPE STRING,
REP24 TYPE STRING,
OTH24 TYPE STRING,
BSPFT TYPE STRING,
CPGLN TYPE STRING,
CPGLS TYPE STRING,
CPGNS TYPE STRING,
CPGSS TYPE STRING,
DVDND TYPE STRING,
INTRS TYPE STRING,
UNSPI TYPE STRING,
TDSOT TYPE STRING,
TDSAT TYPE STRING,
WAEHI TYPE STRING,
INTYP TYPE STRING,
DLART TYPE STRING,
DLARN TYPE STRING,
LSPER TYPE STRING,
LEPER TYPE STRING,
LLMIT TYPE STRING,
LENAM TYPE STRING,
LEAD1 TYPE STRING,
LEAD2 TYPE STRING,
LEAD3 TYPE STRING,
LEPAN TYPE STRING,
LETYP TYPE STRING,
DVDED TYPE STRING,
INTST TYPE STRING,
DEDIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIN_SS_IFOS_HP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIN_SS_IFOS_HP_STR-PRPNO sy-vline
WA_PIN_SS_IFOS_HP_STR-RDVAL sy-vline
WA_PIN_SS_IFOS_HP_STR-ENVAL sy-vline
WA_PIN_SS_IFOS_HP_STR-RENTO sy-vline
WA_PIN_SS_IFOS_HP_STR-LETVL sy-vline
WA_PIN_SS_IFOS_HP_STR-SEC23 sy-vline
WA_PIN_SS_IFOS_HP_STR-INT24 sy-vline
WA_PIN_SS_IFOS_HP_STR-REP24 sy-vline
WA_PIN_SS_IFOS_HP_STR-OTH24 sy-vline
WA_PIN_SS_IFOS_HP_STR-BSPFT sy-vline
WA_PIN_SS_IFOS_HP_STR-CPGLN sy-vline
WA_PIN_SS_IFOS_HP_STR-CPGLS sy-vline
WA_PIN_SS_IFOS_HP_STR-CPGNS sy-vline
WA_PIN_SS_IFOS_HP_STR-CPGSS sy-vline
WA_PIN_SS_IFOS_HP_STR-DVDND sy-vline
WA_PIN_SS_IFOS_HP_STR-INTRS sy-vline
WA_PIN_SS_IFOS_HP_STR-UNSPI sy-vline
WA_PIN_SS_IFOS_HP_STR-TDSOT sy-vline
WA_PIN_SS_IFOS_HP_STR-TDSAT sy-vline
WA_PIN_SS_IFOS_HP_STR-WAEHI sy-vline
WA_PIN_SS_IFOS_HP_STR-INTYP sy-vline
WA_PIN_SS_IFOS_HP_STR-DLART sy-vline
WA_PIN_SS_IFOS_HP_STR-DLARN sy-vline
WA_PIN_SS_IFOS_HP_STR-LSPER sy-vline
WA_PIN_SS_IFOS_HP_STR-LEPER sy-vline
WA_PIN_SS_IFOS_HP_STR-LLMIT sy-vline
WA_PIN_SS_IFOS_HP_STR-LENAM sy-vline
WA_PIN_SS_IFOS_HP_STR-LEAD1 sy-vline
WA_PIN_SS_IFOS_HP_STR-LEAD2 sy-vline
WA_PIN_SS_IFOS_HP_STR-LEAD3 sy-vline
WA_PIN_SS_IFOS_HP_STR-LEPAN sy-vline
WA_PIN_SS_IFOS_HP_STR-LETYP sy-vline
WA_PIN_SS_IFOS_HP_STR-DVDED sy-vline
WA_PIN_SS_IFOS_HP_STR-INTST sy-vline
WA_PIN_SS_IFOS_HP_STR-DEDIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.