ABAP Select data from SAP table PINPEC7 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PINPEC7 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PINPEC7. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PINPEC7 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PINPEC7 TYPE STANDARD TABLE OF PINPEC7, WA_PINPEC7 TYPE PINPEC7, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PINPEC7> TYPE PINPEC7. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PINPEC7. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PINPEC7 INTO TABLE IT_PINPEC7. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PINPEC7 * INTO TABLE @DATA(IT_PINPEC72). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PINPEC7 INDEX 1 INTO DATA(WA_PINPEC72). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PINPEC7 ASSIGNING <PINPEC7>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PINPEC7>-MANDT = 1.
<PINPEC7>-POGUI = 1.
<PINPEC7>-VERSN = 1.
<PINPEC7>-STPID = 1.
<PINPEC7>-CLSEQ = 1.
ENDLOOP. LOOP AT IT_PINPEC7 INTO WA_PINPEC7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PINPEC7-CLRSL, sy-vline,
WA_PINPEC7-ENDDA, sy-vline,
WA_PINPEC7-BEGDA, sy-vline,
WA_PINPEC7-ACTID, sy-vline,
WA_PINPEC7-ACTYP, sy-vline,
WA_PINPEC7-MASSN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PINPEC7 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PINPEC7 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PINPEC7 INTO WA_PINPEC7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PINPEC7_STR,
MANDT TYPE STRING,
POGUI TYPE STRING,
VERSN TYPE STRING,
STPID TYPE STRING,
CLSEQ TYPE STRING,
CLRSL TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
ACTID TYPE STRING,
ACTYP TYPE STRING,
MASSN TYPE STRING,
MASSG TYPE STRING,
SPDAT TYPE STRING,
SPDAY TYPE STRING,
SPMNT TYPE STRING,
PMDAY TYPE STRING,
FRMD TYPE STRING,END OF T_EKKO_STR. DATA: WA_PINPEC7_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PINPEC7_STR-MANDT sy-vline
WA_PINPEC7_STR-POGUI sy-vline
WA_PINPEC7_STR-VERSN sy-vline
WA_PINPEC7_STR-STPID sy-vline
WA_PINPEC7_STR-CLSEQ sy-vline
WA_PINPEC7_STR-CLRSL sy-vline
WA_PINPEC7_STR-ENDDA sy-vline
WA_PINPEC7_STR-BEGDA sy-vline
WA_PINPEC7_STR-ACTID sy-vline
WA_PINPEC7_STR-ACTYP sy-vline
WA_PINPEC7_STR-MASSN sy-vline
WA_PINPEC7_STR-MASSG sy-vline
WA_PINPEC7_STR-SPDAT sy-vline
WA_PINPEC7_STR-SPDAY sy-vline
WA_PINPEC7_STR-SPMNT sy-vline
WA_PINPEC7_STR-PMDAY sy-vline
WA_PINPEC7_STR-FRMD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.