ABAP Select data from SAP table PINPEI9 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PINPEI9 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PINPEI9. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PINPEI9 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PINPEI9 TYPE STANDARD TABLE OF PINPEI9,
      WA_PINPEI9 TYPE PINPEI9,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PINPEI9> TYPE PINPEI9.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PINPEI9.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PINPEI9
  INTO TABLE IT_PINPEI9.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PINPEI9
*  INTO TABLE @DATA(IT_PINPEI92).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PINPEI9 INDEX 1 INTO DATA(WA_PINPEI92).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PINPEI9 ASSIGNING <PINPEI9>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PINPEI9>-MANDT = 1.
<PINPEI9>-POGUI = 1.
<PINPEI9>-BEGDA = 1.
<PINPEI9>-ENDDA = 1.
<PINPEI9>-VERSN = 1.
ENDLOOP.

LOOP AT IT_PINPEI9 INTO WA_PINPEI9.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PINPEI9-POLID, sy-vline,
WA_PINPEI9-DESCR, sy-vline,
WA_PINPEI9-AREKY, sy-vline,
WA_PINPEI9-ARDES, sy-vline,
WA_PINPEI9-POCST, sy-vline,
WA_PINPEI9-WAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PINPEI9 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PINPEI9 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PINPEI9 INTO WA_PINPEI9. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ORDOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINPEI9-ORDOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINPEI9-ORDOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MODOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINPEI9-MODOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINPEI9-MODOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CREON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_PINPEI9-CREON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINPEI9-CREON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CHAON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_PINPEI9-CHAON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINPEI9-CHAON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PINPEI9_STR,
MANDT TYPE STRING,
POGUI TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VERSN TYPE STRING,
POLID TYPE STRING,
DESCR TYPE STRING,
AREKY TYPE STRING,
ARDES TYPE STRING,
POCST TYPE STRING,
WAERS TYPE STRING,
GRPID TYPE STRING,
GRDES TYPE STRING,
INITI TYPE STRING,
INDES TYPE STRING,
FREQU TYPE STRING,
FRDES TYPE STRING,
POTYP TYPE STRING,
TYDES TYPE STRING,
POSTS TYPE STRING,
STDES TYPE STRING,
TMPID TYPE STRING,
TMDES TYPE STRING,
ORDOC TYPE STRING,
MODOC TYPE STRING,
CREBY TYPE STRING,
CREON TYPE STRING,
CHABY TYPE STRING,
CHAON TYPE STRING,
RESE1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PINPEI9_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PINPEI9_STR-MANDT sy-vline
WA_PINPEI9_STR-POGUI sy-vline
WA_PINPEI9_STR-BEGDA sy-vline
WA_PINPEI9_STR-ENDDA sy-vline
WA_PINPEI9_STR-VERSN sy-vline
WA_PINPEI9_STR-POLID sy-vline
WA_PINPEI9_STR-DESCR sy-vline
WA_PINPEI9_STR-AREKY sy-vline
WA_PINPEI9_STR-ARDES sy-vline
WA_PINPEI9_STR-POCST sy-vline
WA_PINPEI9_STR-WAERS sy-vline
WA_PINPEI9_STR-GRPID sy-vline
WA_PINPEI9_STR-GRDES sy-vline
WA_PINPEI9_STR-INITI sy-vline
WA_PINPEI9_STR-INDES sy-vline
WA_PINPEI9_STR-FREQU sy-vline
WA_PINPEI9_STR-FRDES sy-vline
WA_PINPEI9_STR-POTYP sy-vline
WA_PINPEI9_STR-TYDES sy-vline
WA_PINPEI9_STR-POSTS sy-vline
WA_PINPEI9_STR-STDES sy-vline
WA_PINPEI9_STR-TMPID sy-vline
WA_PINPEI9_STR-TMDES sy-vline
WA_PINPEI9_STR-ORDOC sy-vline
WA_PINPEI9_STR-MODOC sy-vline
WA_PINPEI9_STR-CREBY sy-vline
WA_PINPEI9_STR-CREON sy-vline
WA_PINPEI9_STR-CHABY sy-vline
WA_PINPEI9_STR-CHAON sy-vline
WA_PINPEI9_STR-RESE1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.