ABAP Select data from SAP table PIQEDS_SU_OVW into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIQEDS_SU_OVW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIQEDS_SU_OVW. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PIQEDS_SU_OVW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PIQEDS_SU_OVW TYPE STANDARD TABLE OF PIQEDS_SU_OVW, WA_PIQEDS_SU_OVW TYPE PIQEDS_SU_OVW, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PIQEDS_SU_OVW> TYPE PIQEDS_SU_OVW. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PIQEDS_SU_OVW. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PIQEDS_SU_OVW INTO TABLE IT_PIQEDS_SU_OVW. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PIQEDS_SU_OVW * INTO TABLE @DATA(IT_PIQEDS_SU_OVW2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PIQEDS_SU_OVW INDEX 1 INTO DATA(WA_PIQEDS_SU_OVW2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PIQEDS_SU_OVW ASSIGNING <PIQEDS_SU_OVW>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIQEDS_SU_OVW>-SU_OBJID = 1.
<PIQEDS_SU_OVW>-SU_SHORT = 1.
<PIQEDS_SU_OVW>-SU_STEXT = 1.
<PIQEDS_SU_OVW>-SCALEID = 1.
<PIQEDS_SU_OVW>-SUDEFAULT = 1.
ENDLOOP. LOOP AT IT_PIQEDS_SU_OVW INTO WA_PIQEDS_SU_OVW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PIQEDS_SU_OVW-SUCORE, sy-vline,
WA_PIQEDS_SU_OVW-SULEVEL, sy-vline,
WA_PIQEDS_SU_OVW-SUDISCIP, sy-vline,
WA_PIQEDS_SU_OVW-SUCATEGORY, sy-vline,
WA_PIQEDS_SU_OVW-REMEDIAL, sy-vline,
WA_PIQEDS_SU_OVW-SU_DESCRIPTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIQEDS_SU_OVW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIQEDS_SU_OVW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIQEDS_SU_OVW INTO WA_PIQEDS_SU_OVW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIQEDS_SU_OVW_STR,
SU_OBJID TYPE STRING,
SU_SHORT TYPE STRING,
SU_STEXT TYPE STRING,
SCALEID TYPE STRING,
SUDEFAULT TYPE STRING,
SUCORE TYPE STRING,
SULEVEL TYPE STRING,
SUDISCIP TYPE STRING,
SUCATEGORY TYPE STRING,
REMEDIAL TYPE STRING,
SU_DESCRIPTION TYPE STRING,
SELECTED_POPIN TYPE STRING,
SULEVELT TYPE STRING,
SCALET TYPE STRING,
SUCATEGORYT TYPE STRING,
AGM_EXIST TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIQEDS_SU_OVW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIQEDS_SU_OVW_STR-SU_OBJID sy-vline
WA_PIQEDS_SU_OVW_STR-SU_SHORT sy-vline
WA_PIQEDS_SU_OVW_STR-SU_STEXT sy-vline
WA_PIQEDS_SU_OVW_STR-SCALEID sy-vline
WA_PIQEDS_SU_OVW_STR-SUDEFAULT sy-vline
WA_PIQEDS_SU_OVW_STR-SUCORE sy-vline
WA_PIQEDS_SU_OVW_STR-SULEVEL sy-vline
WA_PIQEDS_SU_OVW_STR-SUDISCIP sy-vline
WA_PIQEDS_SU_OVW_STR-SUCATEGORY sy-vline
WA_PIQEDS_SU_OVW_STR-REMEDIAL sy-vline
WA_PIQEDS_SU_OVW_STR-SU_DESCRIPTION sy-vline
WA_PIQEDS_SU_OVW_STR-SELECTED_POPIN sy-vline
WA_PIQEDS_SU_OVW_STR-SULEVELT sy-vline
WA_PIQEDS_SU_OVW_STR-SCALET sy-vline
WA_PIQEDS_SU_OVW_STR-SUCATEGORYT sy-vline
WA_PIQEDS_SU_OVW_STR-AGM_EXIST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.