ABAP Select data from SAP table PJP_NRP_PR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PJP_NRP_PR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PJP_NRP_PR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PJP_NRP_PR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PJP_NRP_PR TYPE STANDARD TABLE OF PJP_NRP_PR,
      WA_PJP_NRP_PR TYPE PJP_NRP_PR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PJP_NRP_PR> TYPE PJP_NRP_PR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PJP_NRP_PR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PJP_NRP_PR
  INTO TABLE IT_PJP_NRP_PR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PJP_NRP_PR
*  INTO TABLE @DATA(IT_PJP_NRP_PR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PJP_NRP_PR INDEX 1 INTO DATA(WA_PJP_NRP_PR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PJP_NRP_PR ASSIGNING <PJP_NRP_PR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PJP_NRP_PR>-WAREKI_TITLE = 1.
<PJP_NRP_PR>-ADDRESS = 1.
<PJP_NRP_PR>-NAME = 1.
<PJP_NRP_PR>-PAYID_1 = 1.
<PJP_NRP_PR>-SHDYS_1 = 1.
ENDLOOP.

LOOP AT IT_PJP_NRP_PR INTO WA_PJP_NRP_PR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PJP_NRP_PR-SHPAY_1, sy-vline,
WA_PJP_NRP_PR-SHPAU_1, sy-vline,
WA_PJP_NRP_PR-SHTAX_1, sy-vline,
WA_PJP_NRP_PR-PAYID_2, sy-vline,
WA_PJP_NRP_PR-SHDYS_2, sy-vline,
WA_PJP_NRP_PR-SHPAY_2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PJP_NRP_PR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PJP_NRP_PR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PJP_NRP_PR INTO WA_PJP_NRP_PR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PJP_NRP_PR_STR,
WAREKI_TITLE TYPE STRING,
ADDRESS TYPE STRING,
NAME TYPE STRING,
PAYID_1 TYPE STRING,
SHDYS_1 TYPE STRING,
SHPAY_1 TYPE STRING,
SHPAU_1 TYPE STRING,
SHTAX_1 TYPE STRING,
PAYID_2 TYPE STRING,
SHDYS_2 TYPE STRING,
SHPAY_2 TYPE STRING,
SHPAU_2 TYPE STRING,
SHTAX_2 TYPE STRING,
PAYID_3 TYPE STRING,
SHDYS_3 TYPE STRING,
SHPAY_3 TYPE STRING,
SHPAU_3 TYPE STRING,
SHTAX_3 TYPE STRING,
PAYID_4 TYPE STRING,
SHDYS_4 TYPE STRING,
SHPAY_4 TYPE STRING,
SHPAU_4 TYPE STRING,
SHTAX_4 TYPE STRING,
ADM_ADDR TYPE STRING,
ADM_KANJI TYPE STRING,
RETIRE TYPE STRING,
SRVYR TYPE STRING,
ENTRYDATE_WAREKI TYPE STRING,
LEAVINGDATE_WAREKI TYPE STRING,
COMMENTS TYPE STRING,
INDNR TYPE STRING,
COMPANY_A TYPE STRING,
COMPANY_NAME_A TYPE STRING,
TELNR TYPE STRING,
CORPN TYPE STRING,
WAERS TYPE STRING,
CUSTOM TYPE STRING,END OF T_EKKO_STR. DATA: WA_PJP_NRP_PR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PJP_NRP_PR_STR-WAREKI_TITLE sy-vline
WA_PJP_NRP_PR_STR-ADDRESS sy-vline
WA_PJP_NRP_PR_STR-NAME sy-vline
WA_PJP_NRP_PR_STR-PAYID_1 sy-vline
WA_PJP_NRP_PR_STR-SHDYS_1 sy-vline
WA_PJP_NRP_PR_STR-SHPAY_1 sy-vline
WA_PJP_NRP_PR_STR-SHPAU_1 sy-vline
WA_PJP_NRP_PR_STR-SHTAX_1 sy-vline
WA_PJP_NRP_PR_STR-PAYID_2 sy-vline
WA_PJP_NRP_PR_STR-SHDYS_2 sy-vline
WA_PJP_NRP_PR_STR-SHPAY_2 sy-vline
WA_PJP_NRP_PR_STR-SHPAU_2 sy-vline
WA_PJP_NRP_PR_STR-SHTAX_2 sy-vline
WA_PJP_NRP_PR_STR-PAYID_3 sy-vline
WA_PJP_NRP_PR_STR-SHDYS_3 sy-vline
WA_PJP_NRP_PR_STR-SHPAY_3 sy-vline
WA_PJP_NRP_PR_STR-SHPAU_3 sy-vline
WA_PJP_NRP_PR_STR-SHTAX_3 sy-vline
WA_PJP_NRP_PR_STR-PAYID_4 sy-vline
WA_PJP_NRP_PR_STR-SHDYS_4 sy-vline
WA_PJP_NRP_PR_STR-SHPAY_4 sy-vline
WA_PJP_NRP_PR_STR-SHPAU_4 sy-vline
WA_PJP_NRP_PR_STR-SHTAX_4 sy-vline
WA_PJP_NRP_PR_STR-ADM_ADDR sy-vline
WA_PJP_NRP_PR_STR-ADM_KANJI sy-vline
WA_PJP_NRP_PR_STR-RETIRE sy-vline
WA_PJP_NRP_PR_STR-SRVYR sy-vline
WA_PJP_NRP_PR_STR-ENTRYDATE_WAREKI sy-vline
WA_PJP_NRP_PR_STR-LEAVINGDATE_WAREKI sy-vline
WA_PJP_NRP_PR_STR-COMMENTS sy-vline
WA_PJP_NRP_PR_STR-INDNR sy-vline
WA_PJP_NRP_PR_STR-COMPANY_A sy-vline
WA_PJP_NRP_PR_STR-COMPANY_NAME_A sy-vline
WA_PJP_NRP_PR_STR-TELNR sy-vline
WA_PJP_NRP_PR_STR-CORPN sy-vline
WA_PJP_NRP_PR_STR-WAERS sy-vline
WA_PJP_NRP_PR_STR-CUSTOM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.