ABAP Select data from SAP table PLFVD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLFVD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLFVD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLFVD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLFVD TYPE STANDARD TABLE OF PLFVD,
      WA_PLFVD TYPE PLFVD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLFVD> TYPE PLFVD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLFVD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLFVD
  INTO TABLE IT_PLFVD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLFVD
*  INTO TABLE @DATA(IT_PLFVD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLFVD INDEX 1 INTO DATA(WA_PLFVD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLFVD ASSIGNING <PLFVD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLFVD>-MANDT = 1.
<PLFVD>-PLNTY = 1.
<PLFVD>-PLNNR = 1.
<PLFVD>-PLNKN = 1.
<PLFVD>-PLNPH = 1.
ENDLOOP.

LOOP AT IT_PLFVD INTO WA_PLFVD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLFVD-PLNFT, sy-vline,
WA_PLFVD-MKMZL, sy-vline,
WA_PLFVD-ZAEHL, sy-vline,
WA_PLFVD-DATUV, sy-vline,
WA_PLFVD-LOEKZ, sy-vline,
WA_PLFVD-AENNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLFVD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLFVD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLFVD INTO WA_PLFVD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLFVD-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLFVD-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field FVLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLFVD-FVLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-FVLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ATINN, internal->external for field ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_PLFVD-ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-ATINN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATAWE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLFVD-ATAWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-ATAWE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATAW1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLFVD-ATAW1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-ATAW1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PLFVD-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLFVD-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLFVD-MSEHI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLFVD_STR,
MANDT TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNKN TYPE STRING,
PLNPH TYPE STRING,
PLNFT TYPE STRING,
MKMZL TYPE STRING,
ZAEHL TYPE STRING,
DATUV TYPE STRING,
LOEKZ TYPE STRING,
AENNR TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
FVLNR TYPE STRING,
ATINN TYPE STRING,
ATZHL TYPE STRING,
ATWRT TYPE STRING,
ATFLV TYPE STRING,
ATFLB TYPE STRING,
ATCOD TYPE STRING,
ATAWE TYPE STRING,
ATAW1 TYPE STRING,
ATFOR TYPE STRING,
WRTKZ TYPE STRING,
MEINN TYPE STRING,
VEINN TYPE STRING,
TXTSP TYPE STRING,
VALID_TO TYPE STRING,
LOEKZ_INHERITED TYPE STRING,
ATBEZ TYPE STRING,
PAWRT TYPE STRING,
MSEHI TYPE STRING,
PAHSC TYPE STRING,
PAHER TYPE STRING,
MSTUF TYPE STRING,
TOPNR TYPE STRING,
INDEX_PLFV TYPE STRING,
ATNAM TYPE STRING,
TXTRF TYPE STRING,
ATFKT TYPE STRING,
AUTOVAL TYPE STRING,
ATOBL TYPE STRING,
ATWRTSHOW TYPE STRING,
ATKON TYPE STRING,
ANZST TYPE STRING,
ATTBL TYPE STRING,
ATFLD TYPE STRING,
ATPID TYPE STRING,
DATUB TYPE STRING,
WERKS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLFVD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLFVD_STR-MANDT sy-vline
WA_PLFVD_STR-PLNTY sy-vline
WA_PLFVD_STR-PLNNR sy-vline
WA_PLFVD_STR-PLNKN sy-vline
WA_PLFVD_STR-PLNPH sy-vline
WA_PLFVD_STR-PLNFT sy-vline
WA_PLFVD_STR-MKMZL sy-vline
WA_PLFVD_STR-ZAEHL sy-vline
WA_PLFVD_STR-DATUV sy-vline
WA_PLFVD_STR-LOEKZ sy-vline
WA_PLFVD_STR-AENNR sy-vline
WA_PLFVD_STR-ANDAT sy-vline
WA_PLFVD_STR-ANNAM sy-vline
WA_PLFVD_STR-AEDAT sy-vline
WA_PLFVD_STR-AENAM sy-vline
WA_PLFVD_STR-FVLNR sy-vline
WA_PLFVD_STR-ATINN sy-vline
WA_PLFVD_STR-ATZHL sy-vline
WA_PLFVD_STR-ATWRT sy-vline
WA_PLFVD_STR-ATFLV sy-vline
WA_PLFVD_STR-ATFLB sy-vline
WA_PLFVD_STR-ATCOD sy-vline
WA_PLFVD_STR-ATAWE sy-vline
WA_PLFVD_STR-ATAW1 sy-vline
WA_PLFVD_STR-ATFOR sy-vline
WA_PLFVD_STR-WRTKZ sy-vline
WA_PLFVD_STR-MEINN sy-vline
WA_PLFVD_STR-VEINN sy-vline
WA_PLFVD_STR-TXTSP sy-vline
WA_PLFVD_STR-VALID_TO sy-vline
WA_PLFVD_STR-LOEKZ_INHERITED sy-vline
WA_PLFVD_STR-ATBEZ sy-vline
WA_PLFVD_STR-PAWRT sy-vline
WA_PLFVD_STR-MSEHI sy-vline
WA_PLFVD_STR-PAHSC sy-vline
WA_PLFVD_STR-PAHER sy-vline
WA_PLFVD_STR-MSTUF sy-vline
WA_PLFVD_STR-TOPNR sy-vline
WA_PLFVD_STR-INDEX_PLFV sy-vline
WA_PLFVD_STR-ATNAM sy-vline
WA_PLFVD_STR-TXTRF sy-vline
WA_PLFVD_STR-ATFKT sy-vline
WA_PLFVD_STR-AUTOVAL sy-vline
WA_PLFVD_STR-ATOBL sy-vline
WA_PLFVD_STR-ATWRTSHOW sy-vline
WA_PLFVD_STR-ATKON sy-vline
WA_PLFVD_STR-ANZST sy-vline
WA_PLFVD_STR-ATTBL sy-vline
WA_PLFVD_STR-ATFLD sy-vline
WA_PLFVD_STR-ATPID sy-vline
WA_PLFVD_STR-DATUB sy-vline
WA_PLFVD_STR-WERKS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.