ABAP Select data from SAP table PLM_QM_NOTIF_FIELDS_OBJECT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLM_QM_NOTIF_FIELDS_OBJECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLM_QM_NOTIF_FIELDS_OBJECT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLM_QM_NOTIF_FIELDS_OBJECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLM_QM_NOTIF_FIELDS_OBJECT TYPE STANDARD TABLE OF PLM_QM_NOTIF_FIELDS_OBJECT,
      WA_PLM_QM_NOTIF_FIELDS_OBJECT TYPE PLM_QM_NOTIF_FIELDS_OBJECT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLM_QM_NOTIF_FIELDS_OBJECT> TYPE PLM_QM_NOTIF_FIELDS_OBJECT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLM_QM_NOTIF_FIELDS_OBJECT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLM_QM_NOTIF_FIELDS_OBJECT
  INTO TABLE IT_PLM_QM_NOTIF_FIELDS_OBJECT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLM_QM_NOTIF_FIELDS_OBJECT
*  INTO TABLE @DATA(IT_PLM_QM_NOTIF_FIELDS_OBJECT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLM_QM_NOTIF_FIELDS_OBJECT INDEX 1 INTO DATA(WA_PLM_QM_NOTIF_FIELDS_OBJECT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLM_QM_NOTIF_FIELDS_OBJECT ASSIGNING <PLM_QM_NOTIF_FIELDS_OBJECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLM_QM_NOTIF_FIELDS_OBJECT>-MATNR = 1.
<PLM_QM_NOTIF_FIELDS_OBJECT>-MAWERK = 1.
<PLM_QM_NOTIF_FIELDS_OBJECT>-REVLV = 1.
<PLM_QM_NOTIF_FIELDS_OBJECT>-ARBPL = 1.
<PLM_QM_NOTIF_FIELDS_OBJECT>-ARBPLWERK = 1.
ENDLOOP.

LOOP AT IT_PLM_QM_NOTIF_FIELDS_OBJECT INTO WA_PLM_QM_NOTIF_FIELDS_OBJECT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLM_QM_NOTIF_FIELDS_OBJECT-EQUNR, sy-vline,
WA_PLM_QM_NOTIF_FIELDS_OBJECT-TPLNR, sy-vline,
WA_PLM_QM_NOTIF_FIELDS_OBJECT-BAUTL, sy-vline,
WA_PLM_QM_NOTIF_FIELDS_OBJECT-SERIALNR, sy-vline,
WA_PLM_QM_NOTIF_FIELDS_OBJECT-CHARG, sy-vline,
WA_PLM_QM_NOTIF_FIELDS_OBJECT-LGORTCHARG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLM_QM_NOTIF_FIELDS_OBJECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLM_QM_NOTIF_FIELDS_OBJECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLM_QM_NOTIF_FIELDS_OBJECT INTO WA_PLM_QM_NOTIF_FIELDS_OBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-REVLV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-SERIALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-SERIALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FERTAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLM_QM_NOTIF_FIELDS_OBJECT-FERTAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_QM_NOTIF_FIELDS_OBJECT-FERTAUFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLM_QM_NOTIF_FIELDS_OBJECT_STR,
MATNR TYPE STRING,
MAWERK TYPE STRING,
REVLV TYPE STRING,
ARBPL TYPE STRING,
ARBPLWERK TYPE STRING,
EQUNR TYPE STRING,
TPLNR TYPE STRING,
BAUTL TYPE STRING,
SERIALNR TYPE STRING,
CHARG TYPE STRING,
LGORTCHARG TYPE STRING,
REFNUM TYPE STRING,
FERTAUFNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-MATNR sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-MAWERK sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-REVLV sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-ARBPL sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-ARBPLWERK sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-EQUNR sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-TPLNR sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-BAUTL sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-SERIALNR sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-CHARG sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-LGORTCHARG sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-REFNUM sy-vline
WA_PLM_QM_NOTIF_FIELDS_OBJECT_STR-FERTAUFNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.