ABAP Select data from SAP table PLMLV_00005151 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMLV_00005151 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMLV_00005151. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PLMLV_00005151 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PLMLV_00005151 TYPE STANDARD TABLE OF PLMLV_00005151, WA_PLMLV_00005151 TYPE PLMLV_00005151, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PLMLV_00005151> TYPE PLMLV_00005151. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PLMLV_00005151. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PLMLV_00005151 INTO TABLE IT_PLMLV_00005151. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PLMLV_00005151 * INTO TABLE @DATA(IT_PLMLV_000051512). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PLMLV_00005151 INDEX 1 INTO DATA(WA_PLMLV_000051512). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PLMLV_00005151 ASSIGNING <PLMLV_00005151>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMLV_00005151>-MSGFN = 1.
<PLMLV_00005151>-VAR_TAB = 1.
<PLMLV_00005151>-STATUS = 1.
<PLMLV_00005151>-VTGROUP = 1.
<PLMLV_00005151>-AUTHSTRUC = 1.
ENDLOOP. LOOP AT IT_PLMLV_00005151 INTO WA_PLMLV_00005151. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PLMLV_00005151-AUTHENTRY, sy-vline,
WA_PLMLV_00005151-FLDELETE, sy-vline,
WA_PLMLV_00005151-DBTABNAME, sy-vline,
WA_PLMLV_00005151-DBCONACTIVE, sy-vline,
WA_PLMLV_00005151-PRESDEC, sy-vline,
WA_PLMLV_00005151-PROC_MODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMLV_00005151 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMLV_00005151 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMLV_00005151 INTO WA_PLMLV_00005151. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLV_00005151-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLV_00005151-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMLV_00005151_STR,
MSGFN TYPE STRING,
VAR_TAB TYPE STRING,
STATUS TYPE STRING,
VTGROUP TYPE STRING,
AUTHSTRUC TYPE STRING,
AUTHENTRY TYPE STRING,
FLDELETE TYPE STRING,
DBTABNAME TYPE STRING,
DBCONACTIVE TYPE STRING,
PRESDEC TYPE STRING,
PROC_MODE TYPE STRING,
E1DATEM TYPE STRING,
MSGFN TYPE STRING,
KEY_DATE TYPE STRING,
AENNR TYPE STRING,
EFFECTIVITY TYPE STRING,
E1CUV1M TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMLV_00005151_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMLV_00005151_STR-MSGFN sy-vline
WA_PLMLV_00005151_STR-VAR_TAB sy-vline
WA_PLMLV_00005151_STR-STATUS sy-vline
WA_PLMLV_00005151_STR-VTGROUP sy-vline
WA_PLMLV_00005151_STR-AUTHSTRUC sy-vline
WA_PLMLV_00005151_STR-AUTHENTRY sy-vline
WA_PLMLV_00005151_STR-FLDELETE sy-vline
WA_PLMLV_00005151_STR-DBTABNAME sy-vline
WA_PLMLV_00005151_STR-DBCONACTIVE sy-vline
WA_PLMLV_00005151_STR-PRESDEC sy-vline
WA_PLMLV_00005151_STR-PROC_MODE sy-vline
WA_PLMLV_00005151_STR-E1DATEM sy-vline
WA_PLMLV_00005151_STR-MSGFN sy-vline
WA_PLMLV_00005151_STR-KEY_DATE sy-vline
WA_PLMLV_00005151_STR-AENNR sy-vline
WA_PLMLV_00005151_STR-EFFECTIVITY sy-vline
WA_PLMLV_00005151_STR-E1CUV1M sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.