ABAP Select data from SAP table PLMM_AUDIT_CD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMM_AUDIT_CD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMM_AUDIT_CD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PLMM_AUDIT_CD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PLMM_AUDIT_CD TYPE STANDARD TABLE OF PLMM_AUDIT_CD, WA_PLMM_AUDIT_CD TYPE PLMM_AUDIT_CD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PLMM_AUDIT_CD> TYPE PLMM_AUDIT_CD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PLMM_AUDIT_CD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PLMM_AUDIT_CD INTO TABLE IT_PLMM_AUDIT_CD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PLMM_AUDIT_CD * INTO TABLE @DATA(IT_PLMM_AUDIT_CD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PLMM_AUDIT_CD INDEX 1 INTO DATA(WA_PLMM_AUDIT_CD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PLMM_AUDIT_CD ASSIGNING <PLMM_AUDIT_CD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMM_AUDIT_CD>-CLIENT = 1.
<PLMM_AUDIT_CD>-GUID = 1.
<PLMM_AUDIT_CD>-ORIGINAL_LANGU = 1.
<PLMM_AUDIT_CD>-AUDIT_TYPE = 1.
<PLMM_AUDIT_CD>-AUTH_GROUP = 1.
ENDLOOP. LOOP AT IT_PLMM_AUDIT_CD INTO WA_PLMM_AUDIT_CD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PLMM_AUDIT_CD-GROUPING, sy-vline,
WA_PLMM_AUDIT_CD-SEARCH_FIELD, sy-vline,
WA_PLMM_AUDIT_CD-CAUSE, sy-vline,
WA_PLMM_AUDIT_CD-UNPLANNED, sy-vline,
WA_PLMM_AUDIT_CD-NEXT_AUDIT_DATE, sy-vline,
WA_PLMM_AUDIT_CD-NEXT_AUDIT_OBLIG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMM_AUDIT_CD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMM_AUDIT_CD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMM_AUDIT_CD INTO WA_PLMM_AUDIT_CD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field ORIGINAL_LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PLMM_AUDIT_CD-ORIGINAL_LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMM_AUDIT_CD-ORIGINAL_LANGU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field RELEASED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_PLMM_AUDIT_CD-RELEASED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMM_AUDIT_CD-RELEASED_ON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMM_AUDIT_CD_STR,
CLIENT TYPE STRING,
GUID TYPE STRING,
ORIGINAL_LANGU TYPE STRING,
AUDIT_TYPE TYPE STRING,
AUTH_GROUP TYPE STRING,
GROUPING TYPE STRING,
SEARCH_FIELD TYPE STRING,
CAUSE TYPE STRING,
UNPLANNED TYPE STRING,
NEXT_AUDIT_DATE TYPE STRING,
NEXT_AUDIT_OBLIG TYPE STRING,
SCORE_RES TYPE STRING,
SCORE_MANUAL TYPE STRING,
SCORE_MAX TYPE STRING,
AUDIT_CALCULATE TYPE STRING,
RESULT_PERCENT TYPE STRING,
MIN_RESULT TYPE STRING,
CLASSIFICATION TYPE STRING,
CLASSIFI_CODE TYPE STRING,
CLASSIFI_MAN TYPE STRING,
OK_NOK TYPE STRING,
CONFIDENTIAL TYPE STRING,
RELEASED_ON TYPE STRING,
RELEASED_BY TYPE STRING,
PROC_STATUS TYPE STRING,
HEADER_FMEA TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMM_AUDIT_CD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMM_AUDIT_CD_STR-CLIENT sy-vline
WA_PLMM_AUDIT_CD_STR-GUID sy-vline
WA_PLMM_AUDIT_CD_STR-ORIGINAL_LANGU sy-vline
WA_PLMM_AUDIT_CD_STR-AUDIT_TYPE sy-vline
WA_PLMM_AUDIT_CD_STR-AUTH_GROUP sy-vline
WA_PLMM_AUDIT_CD_STR-GROUPING sy-vline
WA_PLMM_AUDIT_CD_STR-SEARCH_FIELD sy-vline
WA_PLMM_AUDIT_CD_STR-CAUSE sy-vline
WA_PLMM_AUDIT_CD_STR-UNPLANNED sy-vline
WA_PLMM_AUDIT_CD_STR-NEXT_AUDIT_DATE sy-vline
WA_PLMM_AUDIT_CD_STR-NEXT_AUDIT_OBLIG sy-vline
WA_PLMM_AUDIT_CD_STR-SCORE_RES sy-vline
WA_PLMM_AUDIT_CD_STR-SCORE_MANUAL sy-vline
WA_PLMM_AUDIT_CD_STR-SCORE_MAX sy-vline
WA_PLMM_AUDIT_CD_STR-AUDIT_CALCULATE sy-vline
WA_PLMM_AUDIT_CD_STR-RESULT_PERCENT sy-vline
WA_PLMM_AUDIT_CD_STR-MIN_RESULT sy-vline
WA_PLMM_AUDIT_CD_STR-CLASSIFICATION sy-vline
WA_PLMM_AUDIT_CD_STR-CLASSIFI_CODE sy-vline
WA_PLMM_AUDIT_CD_STR-CLASSIFI_MAN sy-vline
WA_PLMM_AUDIT_CD_STR-OK_NOK sy-vline
WA_PLMM_AUDIT_CD_STR-CONFIDENTIAL sy-vline
WA_PLMM_AUDIT_CD_STR-RELEASED_ON sy-vline
WA_PLMM_AUDIT_CD_STR-RELEASED_BY sy-vline
WA_PLMM_AUDIT_CD_STR-PROC_STATUS sy-vline
WA_PLMM_AUDIT_CD_STR-HEADER_FMEA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.